Haupt Pharma Latina Srl
Strada Statale 156 Dei Monti Lepini 47/600, Latina, Italy
FEI 3007687501DUNS 338690598
FDA has 8 inspections on file for Haupt Pharma Latina Srl in Latina, Italy (FEI 3007687501), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
The most recent OAI inspection ended on Feb 21, 2024. 6 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.58.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2026. Its registrant is Haupt Pharma Inc. (D-U-N-S 832651025).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2009–2025
- 1 OAI · 6 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 8
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Oct 18, 2024
- Warning letters
- None on file
- Import refusals
- 6 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to reject all drug product containers and closures.
Training , Education , Experience overall
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.
Buildings not maintained in good state of repair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Following/documenting laboratory controls
Established test procedures and laboratory control mechanisms are not documented at the time of performance.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Show 1 more citation
Washing and toilet facilities are deficient
Washing and toilet facilities lack hot and cold water.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 18, 2024. It asked for a Form 483.
Inspection ending Feb 21, 2024OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 18, 2024FDA-FOIA-2024-9273Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.58Maintenance2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.52Washing and toilet facilities1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007687501, one row per refused product line.
6 refusals from 2018-01-11 to 2024-09-20 · charged UNAPPROVED on 6 · no FDA sample analysis
FDA firm profile- 2024-09-20
AZITHROMYCIN (MACAROLIDES)56IDA76
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-5660756-5/21/1
- 2024-07-25
AZITHROMYCIN (MACAROLIDES)56ICY76
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast ImportsAEK-5505089-0/41/1
- 2021-04-28
SERTRALINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCH78
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-4467796-3/11/1
- 2021-02-26
AZITHROMYCIN (MACAROLIDES)56ICA76
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-8772002-2/11/1
- 2020-10-20
SERTRALINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCA78
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7888202-1/11/1
Show 1 more
- 2018-01-11
AZITHROMYCIN (MACAROLIDES)56ICY76
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-4001717-8/51/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Haupt Pharma Inc.D-U-N-S 832651025
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007687501 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007687501. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.