Jubilant Generics Limited
Village Sikandarpur Bhainswal, Roorkee- Dehradun Highway, Bhagwanpur, Distt. Haridwar, Roorkee, India
FEI 3006895982DUNS 650369221
FDA has 8 inspections on file for Jubilant Generics Limited in Roorkee, India (FEI 3006895982), from 2013 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 1, 2022. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is JUBILANT GENERICS LIMITED (D-U-N-S 650801538).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2013–2024
- 3 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 8
- Requested under FOIA
- 1 request, latest Sep 8, 2022
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Incomplete cleaning investigation records
Written records are not always made of investigations into unexplained occurrences. As per your cleaning verification protocol (PR-CV-22-0021) you performed only [<6] cleaning verification and (b)(4) cleaning verification residue test of swab samples in 2023 for (b)(4) Tablets USP. Deviation investigation (PR# 209693) was opened when unknown extraneous peaks were obtained during the HPLC test of swab samples collected from manufacturing equipment. The swab samples collected at different locations of the cleaned manufacturing equipment were collected before cleaning. Product Name / Batch manufactured before Cleaning (b)(4) (b)(4) Tablets USP ~g / (b)(4) Tablets USP <4 mg / (b)(4) Tablets USP <4 mg / (b)(4) Tablets USP ~g / Review of the Deviation (PR# 209693) revealed the following deficiencies and/or discrepancies: A. Your firm did not identify the root cause. (b)(4) residue when HPLC test for the swab sample taken from the (b)(4) after Phase 1 and Phase 2 investigations (PR# 209693) was ppm against the specification limit. B. Your cleaning records did not identify the equipment or batch information to support the above deviation investigation arising from the extraneous unknown peaks obtained from swab samples taken at various locations on multiple equipment. Your investigation attributed two [illegible], based on LC-MS study; however, your investigation failed to explain why these drugs were found in the cleaning verification swab samples taken from (b)(4) and (b)(4) or take appropriate actions to identify affected lots. C. The above referenced deviation investigation (PR# 209693) was not mentioned in the cleaning verification report (RR-CV-23-0007, dated 05 October 2023) though the report has a separate "Deviation" section. You wrote under this section, "During execution there [was] no discrepancy observed. Hence, no deviation has been reported during cleaning verification of..." A review of the Deviation and related documents indicates the following additional information was observed during the inspection: - The deviation investigation (PR# 209693) remained open while cleaning verification report RR-CV-23-0007 did not reference the deviation. - The failure to identify the root cause of the presence of extraneous peaks (retention times in the HPLC chromatograms) during repeated swab sample analyses on at least two different batches indicates that your cleaning validation and verification is deficient and unreliable. Your impact assessment and CAPA are inadequate. Since January 2022, you have released approximately (b)(4) Tablets USP to the US market. Equipment / Swab Sample Location / Unknown Extraneous Peak / HPLC Retention Time (b)(4) / Inner surface / (b)(4) (b)(4) Gasket / (b)(4) (b)(4) / surface / (b)(4) The remaining extraneous unknown peaks remain unidentified to date. You have distributed these batches to the US market.
- Observation 2
Quality Unit procedures not followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically: A. During the walk-through inspection we observed uncontrolled investigation documents in a locked bin that were placed for shredding. Your SOP QA103, Rev R04, 'Investigation' section 6.3.3 requires, 'Responsible person shall perform the investigation and prepare the investigation electronically as per SOP QA 116 "Management of Electronic Document Management System (EDMS)" for further review and approval'. However, the investigation documents found in the bin were prepared outside of EDMS and do not have EDMS traceability. For example, the signed copy "Experimental analysis protocol" which was signed on 26DEC2023 could neither be located in the corresponding TrackWise deviation record nor located in TrackWise for the existence of such document. Also, your log for the shredder does not identify what type of documents are destroyed. B. Entries for the purported swab samples obtained from cleaning verification and follow-up investigations were not found in their respective logbooks. For example, swab samples were collected from different locations (b)(4) (b)(4) (PR# 209693) during cleaning verification and during investigation (PR# 209693). However, the cleaning logbooks for these equipment did not always show the sample collection activity on the claimed dates. C. Your QC inward sampling log for swab samples contains entries such as 'Complies' meant for test results outcome, but it is not attributable to any analyst or reviewer with date. It is not clear if this entry is made after reviewing all the test results and associated investigations. When asked, your QC manager stated that he was not sure who made those entries, and he cannot verify as it was not signed or dated by anyone for the test results outcome. In addition, this log is not reviewed by the Quality Unit. D. LOT/AR Numbers: Samples collected on 29-Jan-24 for microbiology at 08:14, 08:20, and 08:04. Laminar Air Flow Usage Record shows the samples were not tested until [illegible]. There are no records documenting if these (b)(4) samples were stored in a refrigerator, who would have stored them, or who removed them for testing to verify chain-of-custody. Procedure: QC011 Evaluation of Quality, Revision: 32, Effective Date: 09-Dec-2023, states to analyze (b)(4) samples within [illegible] and store refrigerated for a maximum [illegible]. E. Appropriate controls, including the removal/archival of obsolete recipes, are not placed over your Tablet Compression Machine PR/fCP/012 to ensure only current versions of recipes are selected for use. Recipe (b)(4) PR/fCP012V02 was selected as the current recipe to be used. Its prior (obsolete) version PR/fCP012V01 was not archived and remained on the Industrial Process Control Computer until 29-Jan-2024, approximately 10 months later. F. (b)(4) sampler T-12 was tested for microbiology and results of TNTC/ml on 08-Jan-2024, which is outside the specification of [illegible], a failed result. However, the reviewer did not verify the real plate but used a zoomed photograph on the computer and modified the result to [illegible] FU/ml which is now within the specification limit. G. One or more of your standalone laboratory instruments do not have adequate control. For example, your analytical balances neither have audit trail capabilities nor measured weights sequentially captured. These balances are used for weighing API and in-process testing during in-process, release and stability studies. Currently, the procedures do not involve a second person verification during weighing resulting in lack of traceability for any potential repeat analysis performed during this test.
Show observations 3 to 4
- Observation 3
Inadequate hold time studies
Time limits are not established when appropriate for the completion of all required activities to assure the quality of the drug product. Specifically, the current hold time studies conducted are not representative of the product. The hold time study conducted (b)(4) for (b)(4) tablets USP (b)(4) g, (b)(4) g, (b)(4) mg) used compressed tablets from exhibit batches while the commercial batch size is (b)(4) mg and (b)(4) tablets. The study used amounts and conditions not representative of commercial manufacturing.
- Observation 4
Unvalidated thickness/hardness controls
Control procedures are not established which validate the performance of processes that may be responsible for causing variability in the drug product. Specifically, thickness and hardness specifications for compressed tablets were changed following a challenge study performed under Protocol: PR-Misc-22-0098. At the conclusion of the challenge study the thickness and hardness specifications were changed from [(b)(4)] to [illegible] thickness and [illegible] hardness, respectively. A. The challenge was only performed on (b)(4) strengths. A challenge was not performed on all commercial strengths. B. The minimum amount of tablets needed for the study was not representative. Four trials were performed using the conditions labeled "low-low hardness", "low hardness", "high hardness", and "high-high hardness" values. Each trial only evaluated approximately (b)(4) compressed tablets, which is not representative of a commercial batch. The trials only evaluated approximately (b)(4) tablets per trial. C. The effectiveness check of the hardness and thickness across batches was insufficient. The study evaluated batches: 1 batch at (b)(4) g, 4 batches at (b)(4) mg, and 1 batch at (b)(4) mg and (b)(4) g batch strengths. This does not represent commercial batch variability nor account for single-batch effects.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 1 more citation
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed and documented at the time of performance.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate equipment cleaning and maintenance
OBSERVATION 1 Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A- On March 2, 2021, non-dedicated BY@T 1 equipment P) 002 was observed to contain residue in the BY@TTTT on the back of the . The equipment was identified as cleaned for product change over. Since January 2019, the ®Y#7 equipment has been used to manufacture the following products: Indicated Use EPLOVEETS STRATURE a EMPLOYEES RAVE ARO ITE it or 5p DRTERSTED B- On March 2, 2021, non-dedicated ®)# "7 compression machine PR/TCP/011 was observed to contain @/@T residue (powder) on the®)@ TT after product change over cleaning. Since January 2019, the compression machine has been used to compress the following products: Indicated Use BI ao Bl med me | EE | tablet mg and mg ae A L1 tablets @ mgand®[G [@@TTEET | Compressed tablet batches of products listed in the table above have been distributed to the US Market. Your current product change over cleaning for ®®# 7 compression machine PR/TCP/011 fails to prevent potential product contamination. C- On March 2, 2021, non-dedicated machine P] /001 was observed to contain BY@TTY residue on the wall of the chamber and additionally, particles, were found in the drain pike of chamber. Since January 2019, the (OY&) © machine has been used to ®) the following products: Indicated Use i ables Ql mz nd JG] ——— Batches of products listed in the table above have been distributed to the US Market. Your current product change over cleaning for ®/@ TI machine PRBI@1/001 fails to prevent potential product contamination. D- On March 2, 2021, non-dedicated machine PRAYA@/004 was observed to contain rust like surface in the port of the equipment and a brownish color which appeared to look like rust in the area. Since January 2019, the TI machine has been used to the following products: (DrugName indicated Use I tablets ©) img and {G _ | | SE — tablet mg and for all strength ® ng) Batches of products listed in the table above have been distributed to the US Market. Your current product change over cleaning for PYF machine PR®YA)/004 fails to prevent potential product contamination. E- On March 2, 2021, non-dedicated BENIN machine DL®)II/001 was observed to have and blackish stains in the gasket of the BF area. Since January 2019, the machine has been used to process the following products: | Eel ee i mg rs role | mS and (0) mg Batches of products listed in the table above have been distributed to the US Market. Your current product change over cleaning for BY@) FT machine DLOGY@)/001 fails to prevent potential product contamination. F- Your “Receipt, Inspection, Cleaning, Usage, Polishing and Disposal of Punches and Dies” (PR020-11) procedure, fails to ensure that manufacturing equipment is suitably maintained for its intended purpose. Your maximum tablet limit per punch and die set, is (BY. You failed to provide a sound justification for establishing your maximum punch and die limit. Section 6.3.2.2 of your procedure (PR020-11) indicates that each set of punches and dies procured for production will be destroyed based on a cumulative tablet count. Tablet tracking for each punch set is not performed. You utilize a ®Y# process for all punches at the facility. For example O/T SIT tablets ®)img which are compressed on a on [7 compression machine. You procured (8) punch sets which include upper punch, lo punch and die (per set). During compression of the first set of BIAITINN tablets ©mg, the following punch was utilized: i ll batch Cal J batch CTE SATE ERPEOTERTS RANE ANG ITE Fr a To SATERSUES Your current process fails to account for wear of frequently used punches. On March 8, 2021, the following lower punches were observed to contain edge-wear, EEE and [0] You failed to provide a scientific justification detailing that the defects observed do
Shortened here; the PDF has the full text.
- Observation 2
Inadequate cleaning validation sampling
OBSERVATION 2 Laboratory controls do not include the establishment of scientifically sound and appropriate, sampling plans designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality and purity. ***REPEAT OBSERVATION*** Specifically, A- Your “Management of cleaning validation/verification” “Document number: QA083” procedure does not represent all hard to clean locations. Your facility manufactures a total of different drug products. Critical manufacturing equipment such as GT, Equipment, and compression machines are non-dedicated. Examples of hard to clean surfaces not sampled during cleaning validation include, but not limited to: + BUI: inner surface of the BJ, groove between BIE and BYE, groove between®@ TT and surface ([] area, inside the discharge chute, and groove of the surface VTE. Brownish spots which appeared to be rust was observed in the groove between ®)@" and (OY) for equipment PR/®)#)1/001. + BE Equipment: XENI of the BUEN andBII bove are not sampled. The non-dedicated equipment at the facility is used to manufacture the following (OY) EE molecules: BI I [. Per your Quality Assurance Manager, “cleaning validation is done for ensuring cleaning procedure efficiency to remove residue from the equipment of previous product”. Your current swab sampling location do not represent all hard to clean surfaces. Your current cleaning validation fails to scientifically B- “Dirty hold-time” swab samples obtained from non-dedicated equipment do not represent hard to clean surfaces. Dirty hold-time study was not conducted during cleaning validation performed in December 2020, “Document number: QA083”. Per your Quality Assurance Manager, during cleaning validation conducted in December 2020, product change over cleaning (Type B) was performed immediately after manufacturing. At present, you utilize dirty hold-time established prior to October 2019. Current dirty hold-time study being utilized is not robust to determine removal of previous product with prolonged dirty hold-time storage. The current dirty hold time study being used does not represent the additional hard to clean surfaces noted in “Management of cleaning validation/verification” “Document number: QAO083. For example, the dirty hold-time being used for BY was approved on March 31, 2018 under report “CVR/DEHT/001/18/00". During execution of the ®Y@)] [0 hold-time study, swab samples were not collected from the following hard to clean surfaces: BY@TIIIINT, bottom surface of BMA), and surface of the BEANIE. You currently have no plan on re-executing dirty hold-time and provided no sound justification for utilizing dirty-hold time conducted in March 2018. Additionally, your firm only conducted dirty hold time studies for Compression machine, ED equipment. The rest of the equipment such as the OY rr] and other manufacturing equipment did not have hold times studies. C- Your firm provided no justification for using second/third worst case product to conduct extensive swab sampling. This was a part of your firm’s enhance cleaning validation program by selecting “hard to clean” surfaces which is stated on page 4 of document titled, ‘Cleaning Validation Protocol for Manufacturing and Packing Equipment with Extensive Swab Sampling’ (dated December 31, 2019). Page 14 — 17 documents: Equipment Name, Validation Protocol for Manufacturing and Packing Equipment with Extensive Swab Sampling’ (dated December 31, 2019). Page 14 — 17 documents: Equipment Name, Equipment ID Number and Worst-Case Product. However, upon reviewing the Worst-Case Products used no scientifically documented explanation as to why in some cases number three hard to clean product was used instead of number one or number two hard to clean product is used. For example, 1- (BYE 250 the firm used BY@TTTT tablets which is not listed as a worst to clean product 2- Compression Machine
Shortened here; the PDF has the full text.
Show observations 3 to 4
- Observation 3
Investigations not extended to related products
OBSERVATION 3 Investigations of any unexplained discrepancy, a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy. Specifically, you failed to extend your manufacturing investigation PR58614 to other products manufactured which utilized Acceptance Quality Limit (AQL) for tablet visual inspection. Prior to December 2019, 100% manual visual inspection was not performed for all batches manufactured. You utilized, AQL analysis for batch release to ensure that your manufacturing process contained no critical defects. You define critical defects as defect “with high probability of adversely impacting the safety, purity and effectiveness of the drug product.” On November 21, 2019, you decided to initiate a voluntary recall to withdraw Amantadine Hydrochloride tablets 100mg from the US market. The recall was initiated due to a complaint regarding one compressed tablet containing a foreign particle; which was later identified as ‘®)#)] particle”. You failed to extend your investigation to the other B) batches of drug product which utilized AQL inspection analysis. The ©)" batches are within expiry and are currently on the US market. Adequate impact assessment of batches manufactured using AQL analysis was not performed. You failed to assure that the (8) batches which utilized AQL evaluation are free of critical defects that would affect the safety, purity and effectiveness of your product. EMPLOYEE(S) SIGNATURE / EMPLOYEE(S) NAME AND TITLE (Print or Type) DATE ISSUED Dipesh Shah, CSO 03/12/2021 Rita K Kabaso, CSO
- Observation 4
Insufficient process validation/qualification
OBSERVATION 4 Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. ***REPEAT OBSERVATION*** Specifically, A- You failed to appropriately qualify your 100% automated tablet inspection equipment. Your production block is equipped with ®)@) automated visual inspection machines, (©) @). Since December 2019, all (8) US products undergo 100% automated visual inspection. Your current visual inspection process fails to assure that non-conforming tablets and capsules are rejected. During equipment qualification, the following inadequacies were observed: * Automated visual inspection machine PR/TIM/002 and PR/TIM/003 were executed using PQ/PRTIM002 and PQ/PRTIMO03. Each machine is equipped with B) cameras which detect different defects. During individual camera challenge, you failed to adequately qualify Line {/camera ©)", and Line {/camera ®) to detect different tablet shapes manufactured at your facility. PR/TIMA002 and PR/TIM/003 were only challenged to detect ®)@ shaped tablets. Tablet shapes manufactured in your facility include: ()@). . During individual camera challenge for (0)@) Camera ©®®@ and ®@ Camera ®)@ you failed to ensure that the (0) (4) shape tablets used for thickness challenge are within the high and low thickness range routinely observed during production. Tablet thickness range used during qualification is unknown. In addition, the number of tablets which contained low thickness or high thickness is unknown. EMPLOYEE(S) SIGNATURE / EMPLOYEE(S) NAME AND TITLE (Print or Type) Dipesh Shah, CSO 03/12/2021 Rita K Kabaso, CSO
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Control procedures to monitor and validate performance
Control procedures are not established which of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written program not followed
The written stability testing program is not followed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not suitably located to facilitate operations for its intended use.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 1 more citation
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Sep 8, 2022.
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Sep 8, 2022FDA-FOIA-2022-6479Inspection recordsClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- JUBILANT GENERICS LIMITEDD-U-N-S 650801538
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006895982 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006895982. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.