Skip to content

Beyond Technology Corporation Nanchang

NO 162 Kejidadao, Qingshanhu, Nanchang, China

FEI 3006512913

FDA has one inspection on file for Beyond Technology Corporation Nanchang in Nanchang, China (FEI 3006512913). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDRH).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

FDA’s Red Lists for Import Alerts 66-79 and 89-04 name this firm at this address. FDA printed no FEI on the entries. No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2015
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
66-79, 89-04Red List
Matched on FDA’s firm name and street address

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.

    2. Records not made readily available to FDA

      Records associated with drug product production and distribution and within the retention period for such records, were not made readily available for authorized inspection.

    3. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin.

    4. Washing and toilet facilities are deficient

      Washing and toilet facilities lack soap or detergent and air driers or single-service towels.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    Show 8 more citations
    1. Adequate lighting not provided

      Adequate lighting is not provided in all areas.

    2. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the strength, quality, and purity of drug products.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    5. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

    6. Written procedures followed

      Procedures for the preparation of master production and control records are not described in a written procedure.

    7. Measured components for manufacturing

      Components for drug product manufacturing are not weighed and subdivided as appropriate.

    8. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 12

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDRH · DevicesFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-79Red ListDetention Without Physical Examination of Drugs From Foreign Establishments Refusing FDA InspectionImport alert pageAlert on fda.gov

    Date published 2022-10-13

    FDA’s entry
    Beyond Technology Corporation Nanchang · NO 162 Kejidadao, Qingshanhu, Nanchang, CHINA
    FDA’s inspection record for FEI 3006512913
    Beyond Technology Corporation Nanchang · NO 162 Kejidadao, Qingshanhu, Nanchang, China

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    12 products

    • 53 I - - 01Dentifrices (Aerosol, Liquid, Toothpastes, Toothpowders), without Fluoride (Oral Hygiene Products)
    • 53 I - - 99Other Oral Hygiene Products, without Fluoride, N.E.C.
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    Show 9 more products
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs
  • 89-04Red ListDetention Without Physical Examination of Devices from Firms that Have not met Device Quality System RequirementsImport alert pageAlert on fda.gov

    Date published 2016-08-29

    FDA’s entry
    Beyond Technology Corporation Nanchang · NO 162 Kejidadao, Qingshanhu, Nanchang, CHINA
    FDA’s inspection record for FEI 3006512913
    Beyond Technology Corporation Nanchang · NO 162 Kejidadao, Qingshanhu, Nanchang, China

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    13 products

    • 73 - - - --Anesthesiology
    • 74 - - - --Cardiovascular
    • 76 - - - --Dental
    Show 10 more products
    • 77 - - - --Ear,Nose And Throat
    • 78 - - - --Gastroenterological & Urological
    • 79 - - - --General & Plastic Surgery
    • 80 - - - --General Hospital/Personal Use
    • 84 - - - --Neurological
    • 85 - - - --Obstetrical & Gynecological
    • 86 - - - --Ophthalmic
    • 87 - - - --Orthopedic
    • 89 - - - --Physical Medicine
    • 90 - - - --Radiology

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006512913 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006512913. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.