Skip to content

Medistat RX L.L.C.

110 E Azalea Ave, Foley, Alabama, United States

FEI 3006014626

FDA has 2 inspections on file for Medistat RX L.L.C. in Foley, Alabama (FEI 3006014626), from 2014 to 2015. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Jul 6, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2014–2015
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigation of sterility failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, a) Environmental monitoring failures and trends are not adequately addressed and investigated. During the previous 10 months, numerous organisms have been identified, including gram negative bacteria, yeast, and mold, within ISO 5 hoods on both surfaces and in the air. b) Methylprednisolone 40 mg/mL, Lot 07082015@1, Triamcinolone Acetonide 80 mg/mL, Lot 07072015@1, Tri-Mix (2.5/10/1.25), Lot 07092015@1, and Tri-Mix (2.5/10/1.25), Lot 07092015@2, were released after receiving failing sterility results from their contract laboratory. The investigation concluded it was laboratory error. A new sample of the same size for each product was sent to an alternative laboratory, which produced acceptable results. The products were released and distributed. c) HCG 3000, Lot 12262014@5, JC (50/50/0.175/0.175), Lot 12232014@1, Triamcinolone, Lot 12232014@1, Testosterone Cypionate/Propionate 180/20 mg/mL, Lot 12232014@10 and @11, were released after receiving failing sterility results from their contract laboratory. The investigation concludes analyst error, though there is no evidence to support this conclusion. A new sample of the same size for each product was sent to an alternative laboratory, which produced acceptable results. The products were released and distributed.

    2. Observation 2

      Missing/insufficient aseptic procedures

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Procedures shall include validation of all aseptic and sterilization processes. Specifically, a) Injectable drug suspensions are sterilized in [illegible] located within the ISO 8 Prep Room. The [illegible] have not been qualified and the sterilization cycles have not been validated. There has been no studies or b)(4) determinations. The [b)(4)] are used to sterilize injectable drug products [b)(4)]. b) On 8/31/2015, during observation of compounding of Medroxyprogesterone Suspension Vehicle, Lot 08312015@3, and Medroxyprogesterone Acetate 150 mg/mL, Lot 08312015@2, the following was noted: i. Operators were observed to handle a keyboard, mouse, scanner, phone, and cabinet handle and resume compounding activities without re-sanitizing their hands within the ISO 8 Prep Room. ii. An operator poured Benzyl Alcohol into a depyrogenated [b)(4)] within the ISO 8 Prep Room. iii. During aseptic filling within the ISO 5 Hood, Hood [illegible] open prior to filling [illegible] with product. iv. During aseptic filling within the ISO 5 Hood, the operator was observed to place stoppers on filled vials with tweezers and then push them into the vials using fingers. c) Smoke studies have not been performed in the cleanrooms, including the ISO 5 critical areas, in either static or dynamic conditions. e) There is no viable air monitoring within the ISO 5 hood during aseptic operations.

    Show observations 3 to 11
    1. Observation 3

      Deficient environmental monitoring system

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, on 8/31/2015, after the production of Medroxyprogesterone Acetate 150 mg/mL, lot 08312015@2, an operator was observed to sanitize hands prior to finger plating.

    2. Observation 4

      Inadequate acceptance criteria for particulate

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, a) Visual inspection of injectable products is limited to the presence of particulate matter (PM) for rejection. For example, apparent product residue was observed around and in the closures of 8 vials of Methylprednisolone Acetate 80 mg/mL, Lot 08052015@2, and 2 vials of Lipostat, Lot 07012015@1. This is not considered significant and vials are accepted. b) There is no established limit for PM and excessive rejections were noted for the following: i. MJC 25/50/50/0.175/0.175 mg/mL, Lot 07272015@1, resulted in [illegible] vials. Two hundred twenty-nine (229) vials, were rejected for PM. ii. Triamcinolone Acetate 80 mg/mL, Lot 05192015@1, resulted in [illegible] vials. Seventy four (74) vials were rejected for PM. iii. Tri-Mix 30/10/1 mg/mL, Lot 08032015@3, resulted in [illegible] vials. Twenty seven (27) vials were rejected for PM.

    3. Observation 5

      Deficient pressure/airflow monitoring

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, the design of the clean room is deficient in that: a) Pressure differentials between rooms are not monitored during production. b) There are no gauges between the ISO 8 Prep Room and uncontrolled rooms, and, therefore, no pressure monitoring between the rooms. c) There are openings between the ISO 7 Large Buffer Room and the ISO 8 Prep Room, but there is no pressure differential monitoring between these two rooms to identify which direction air is moving. The ISO 8 Prep Room does not receive HEPA filtered air. d) The hand-washing sink and hand dryer are located directly in front of an air return in the ISO 7 Ante Room. is used for all sanitizing activities within the ISO 8 Prep Room.

    4. Observation 6

      Inadequate cleaning/disinfection system

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) Non-sterile, non-shedding wipes are used in the cleanrooms, including the ISO 5 areas. b) [b)(4)] non-sterile cleaners are used on [illegible] within the cleanroom. Only [OCb) (~)] cleaners acts as a sporicide, which appears to be ineffective or ineffectively used based on the identification of spore-forming bacteria during environmental monitoring.

    5. Observation 7

      Stability program not followed

      The written stability testing program is not followed. Specifically, the procedure for extending expiration dates with stability data, SOP 3.17, is not followed. Stability data is insufficient to support the expiration dates assigned to injectable drug products, which include expiration dates of up to 570 days. Only (b)(4) [illegible] with no testing between [Kb (4)] (5H4J). For example Lipostat, Lipostat Plus, and Sulfa-Free Lipostat are assigned expirations of 570 days and Cyanocobalamin is assigned an expiration of 450 days.

    6. Observation 8

      Containers/closures not validated sterile

      Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use using a validated process. Specifically, vials and glassware used for injectable drug products are sterilized and depyrogenated in-house using [redacted]. Within the ISO 8 Prep Room, vials are [b)(4)] i(b)(2) ?. They are [(6)(2)] in the ISO 7 Ante Room prior to [b)(4)]. [b)(4)] located in uncontrolled rooms, and are [b)(4)]. There has been no [OCb)(4)] studies for the [b)(4)] determined. [b)(4)] are used approximately (5)(4). There is no assurance the vials and glassware are adequately sterilized and depyrogenated.

    7. Observation 9

      Inadequate protective apparel use

      Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, on 8/31/2015, a) During the compounding of Medroxyprogesterone Acetate Suspension Vehicle, Lot 08312015@3, in the ISO 8 Prep Room, I observed personnel to be wearing all non-sterile garb, with the exception of [illegible] gloves. The gloves are not donned in a sterile manner and are sanitized using non-sterile [b)(4)]. b) During the compounding of Medroxyprogesterone Acetate 150 mg/mL, Lot 08312015@2, I observed personnel to be wearing no protective covering over their eyes, cheeks, or forehead, leaving their skin exposed within the ISO 5 critical workzone.

    8. Observation 10

      Incomplete batch production records

      Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, records are sometimes or always lacking the following information: a) Actual and theoretical yield b) Label samples and reconciliation c) Dates for signatures d) Verification of shortage status prior to production e) The number of vials produced, sent for sampling, and kept f) Verification of calculations g) References to investigations h) Final batch disposition i) Batch release signature and date

    9. Observation 11

      Required labeling information missing

      The labels and containers of your outsourcing facility's drug products do not include information required by section 503B(a)(10). Specifically, The following information is not found on some of your drug product labels: 1. The statement "Not for resale." Examples of drug product labels that do not contain this information include: a) Testosterone Cypionate/Testosterone Propionate (80 mg/20 mg)/mL b) Triamcinolone Acetonide USP 80 mg/mL 10 mL Vial c) Trimix (Papaverine 30 mg/Alprostadil 10 mcg/Phentolamine 1 mg/mL) 5 mL Vial

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be pyrogen-free is not laboratory tested to determine conformance to such requirements.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing, processing, and packing of drug products is not appropriate for the duties they perform.

    3. No written record of investigation

      Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

    4. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    5. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    Show 5 more citations
    1. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    3. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    4. Complaints reviewed by Quality Control Unit

      Written procedures describing the handling of complaints do not include provisions for review by the quality control unit of any complaint involving the possible failure of a drug product to meet any of its specifications, a determination as to the need for an investigation of any unexplained discrepancy, and explaining the reasons for the failure of the batch or any of its components to meet specifications.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006014626 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006014626. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.