Tekweld Solutions Inc.
45 Rabro Dr Unit 1, Hauppauge, New York, United States
FEI 3004965821DUNS 169803389
FDA has 2 inspections on file for Tekweld Solutions Inc. in Hauppauge, New York (FEI 3004965821), from 2020 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.22(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for packing, labeling, relabeling and repacking, through Dec 31, 2027. Its registrant is Tekweld Solutions, Inc. (D-U-N-S 169803389).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2020–2025
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Jul 11, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Lack of quality control unit
There is no quality control unit.
Equipment for Environmental Control
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Label reconciliation discrepancies evaluation/investigation
Discrepancies found outside preset limits when reconciling the quantities of labeling issued, used and returned, were not evaluated.
Written procedures describing in detail
There is a lack of written procedures describing in sufficient detail the receipt, identification, handling and examination of labeling and packaging materials.
Packaging line inspection documentation
Results of inspection of packaging and labeling facilities are not documented in the batch production records.
GMP Training Frequency
GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Lack of quality control unit
There is no quality control unit.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 11, 2025. Each one asked for a Form 483.
Inspection ending Jan 16, 2025VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 12, 2026. FDAgent holds no copy that FDA posted.
- Jul 11, 2025FDA-FOIA-2025-8580Form 483· 1 of 2 sitesClosed
- Jun 11, 2025FDA-FOIA-2025-7402Form 483· 1 of 8 sitesWithdrawn
- Mar 20, 2025FDA-FOIA-2025-2606Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.122Materials examination and usage criteria1 of 2
- 21 CFR 211.125Labeling issuance1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
FDA drug establishment registration
FDA registration search- Registered operations
- Packing, labeling, relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- Tekweld Solutions, Inc.D-U-N-S 169803389
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004965821 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004965821. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.