JCB Laboratories LLC
7335 W 33rd St N, Wichita, Kansas, United States
FEI 3004839646
FDA has 3 inspections on file for JCB Laboratories LLC in Wichita, Kansas (FEI 3004839646), from 2013 to 2018. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.160(b).
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2013–2018
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Lack of testing and stability data
There is no testing to assure that a drug product meets applicable standards of identity, strength, quality, and purity at the time of use. Also, there are no written testing programs designed to assess the stability characteristics of drug products. Specifically, A. Your firm lacked valid analytical and stability data to support the 60, 90, and 180-day beyond use-date (BUD) expiration date assigned to all of your products such as Vancomycin, Sodium Thiosulfate, and Ephedrine Sulfate. B. While you began to develop stability protocols for some of your product you fail to have stability data for batches of products in accordance to the protocols you have written. This failure extends to all of your products as you do not have stability data for a representative number of batches for any of your marketed and distributed products. In addition, you do not have an on-going stability program for your products. C. Your firm has incomplete methods and methods validations for the following products: 1. Bevacizumab (Avastin) Injection Solution - no method validation for potency, and no potency testing is performed. 2. Sodium Thiosulfate 25% PF Injection Solution - no method validation for potency, sterility, and endotoxin. 3. EDTA (edetate disodium) Topical Ophthalmic Injection Solution - no method validation for potency, sterility, and endotoxin. 4. Tropicamide 1%, Cyclopentolate 1%, Phenylephrine 2.5%, Ketorolac 0.4%, Proparacaine 0.1% Ophthalmic Solution - no antimicrobial effectiveness testing (USP <51>). 5. Iohexol (Omnipaque) Injection Solution - no method validation for potency, sterility, and endotoxin. 6. Calcium Chloride PF Injection Solution - no method validation for potency, sterility, and endotoxin. Repeat Observation from 02/12-21/13 and 11/16-12/3/15 EI inspections
- Observation 2
Aseptic procedures and controls deficient
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. Specifically, A. The smoke study is deficient as it does not continuously show that the air is moving unidirectionally as the smoke is either too faint and/or the smoke source is depleted and there is no smoke present. In addition, the smoke study was not conducted while simulating your current manufacturing and operating processes (b)(4) laminar flow hoods at the same time which represents your normal processing operations. B. The media fill performed is inadequate as it does not simulate the complete sterile operations for your manufacturing processes as follows: You currently qualify your aseptic operators through your media fill operations but you do not mimic the worst-case manufacturing operations which occur during your aseptic processing operations. For example, (but not limited to): 1. You do not simulate the maximum number of activities which occur during your manufacturing operations. 2. You do not simulate the worst-case activities during your manufacturing operations. 3. You do not simulate the maximum number of people which are involved in the aseptic operations and/or are in the environment during your media fill operations. C. On 8/14/18, I observed your cleaning practice and found you do not follow your SOP no. 3.3010 "Cleaning of the Cleanroom Facility." You failed to use aseptic cleaning techniques as you did not mop the floors, starting in a position that allows the Technician to mop in a uniform manner covering all floor surfaces from the back of the room to the exit. Your Technician stepped over onto the cleaned area after mopping it and they did not always clean from the inside out or from the top downward. D. During your room qualification activities and evaluation of the HEPA filters you do not evaluate the air velocity at the work surface in your ISO-5 laminar flow hoods. In addition, you do not have a system in place to track the repairs made to your HEPA filters which are evaluated during your r(b)(4) evaluations of these filters. E. We identified hold times for your Sodium Thiosulfate 25% PF Injection Solution for up to [illegible]. You do not have bioburden data for this product to support the end hold times used. F. You do not have an SOP which addresses the quality oversight of gowning used during the manufacturing operations and the Quality Unit does not perform oversight of these items used during processing operations for your sterile injectable products. This includes your sleeve covers, coveralls, hoods, and boots. Repeat Observation from 02/12-21/13 EI inspections
Show observations 3 to 10
- Observation 3
Inadequate process controls and inspections
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, A. While you document a visual inspection of your Povidone-Iodine (Betadine) 5% Ophthalmic Solution 1 mL syringe product is being performed, you do not perform a visual inspection of this amber colored product which is packaged in amber syringes. In addition, your SOP for Visual Inspections does not cover a visual inspection process for this product. B. During our review of your visual inspection process on 8/15/18, Employees (b)(6) and (b)(e) were observed performing visual inspections of Omnipaque Injectable Repack Vials lot no. C274-000006332. Your visual inspection process was inadequate because we observed they did not evaluate the units for at least [illegible] in accordance to your SOP.
- Observation 4
Failure to investigate deviations and complaints
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether the batch has been already distributed. Specifically, A. You failed to respond timely to the aberrant test results which later tested as OOS test results for your Cefuroxime Ophthalmic Solution for Injection, Lot no. C274-000002528. On 10/17/17 this lot was tested for potency and received test results of 90.4% [illegible]. This lot was retested in triplicate on 11/16/17 and the results reviewed on 11/20/17 with OOS results of 82.5%, 83.5% and 83.8%. Deviation no. 2017-2017-080 initiated 1/18/18 summarizes these results including a review of the original BUD information which found two of the three BUD studies performed in 2014 indicates the potency of Cefuroxime drops significantly over a short period [illegible] days. DEV-2018-004 initiated on 1/18/18 documents Quality Assurance performed a review of DEV-2017-080 on 1/8/2018. Your Risk Assessment was not approved until 1/12/18, almost 2 months after confirmed OOS test results were received; you initiated NOE 2018-023 on 1/17/18 for Quality Assurance review on 1/8/2018 for stability failure and questionable BUD date approval. Your Health Hazard Evaluation was not approved until 1/26/18 and your Recall notification was dated 1/24/18. B. Deviation no. DEV-2017-071, discovered 10/4/17, documents a complaint received 8/21/17 for Mitomycin Solution for Injection, 0.2 mg/mL, 1 mL Single Use Syringe (ophthalmic use only) for lot no. C2724-000001703. The report was for three (3) patients who experienced reactions on their eye(s) following the use of this product. As a part of the investigation for this complaint retained samples were evaluated including retain samples from other lots. During the review of the retain samples lot no. C274-00000165 was found to have particulates in four units. You failed, however, to test these retain units to identify what the particulates were. During your visual inspection process, your SOP no. 9.200 "Visual Inspection and Defect Recognition" it gives instructions for you to "note any heavy particulates". In addition, you have not identified what these particulates might be and collected information on inherent, intrinsic, and extrinsic particulates which have appeared historically in your product which are identified through training in your visual inspection process. C. Customer Complaint no. 0118-029 was initiated on 19-Jan-2018 for Mitomycin 0.2 mg/mL, lot no. C274-000003188. The complaint was for the presence of a black particle found from your Mitomycin solution. Additional follow-up information was requested for this complaint which you stated the records were unavailable as you could not find the records for our review. This complaint had not been closed and you initiated an NOE and Deviation Report as a result of this event. D. Customer Complaint 0118-017 was initiated 15-Jan-2018 for Cefuroxime lot C274-000003077 and Lidocaine/Phenylephrine lot C274-000002851. The complaint was for patients which had possible TASS or endophthalmitis. During your investigation of this complaint you failed to perform a complete investigation as you did not evaluate your retain samples. E. DEV-2017-054 was initiated on 7/19/2017 after failing sterility results were received for Avastin Solution for Injection, 2.5 mg/0.1 mL, 0.1 mL Fill Lot C274-000001585. Your investigation identified Paenibacillus taichungensis in the (b)(4) media and a Paenibacillus species in your (b)(4) media for this product. You failed to include environmental monitoring information in your investigation where you found this organism in your environment on 06/16/17 and 06/21/17. In addition, you did not initiate corrective and preventive actions as a response to this event. Repeat Observation from 02/12-21/13 and 11/16-12/3/15 EI inspections
- Observation 5
Inadequate temperature monitoring and storage
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected. Specifically, A. API drug products were observed on 8/14/18 in an area of your warehouse where there is no temperature monitoring performed. The following products were observed locked up in your quarantine area in the receiving area of your warehouse and include the following: 1. Gentamicin Injectable, USP, lot [illegible], the label reads "store at USP controlled room temperature 20-25°C (66-77°F)." This API product is used in your Sodium Citrate 4% product. 2. Omnipaque, lot [b)(4)]. This is a product you repackage and the label reads store at 20-25°C (59-80°F). 3. Phenol Liquid 90%, lot no. [b)(4)] label read "Store at Room Temperature". B. Temperature mapping studies have not been performed in the areas where raw materials and finished drug products are stored.
- Observation 6
Aseptic core facility disrepair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, The floor in aseptic core is not cured properly and appears dirty in several areas throughout the aseptic core. On 8/13/18, we observed areas around the bottom of carts which appeared to be rust. We were told "cleaners are used which are caustic and they erode the metal."
- Observation 7
Incomplete labeling control records
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced. Specifically, The retain samples for this product along with all finished product do not contain the same labels as finished products. The use of other labels prevents your complete review of your distributed product including labeling.
- Observation 8
Failure to follow production and change procedures
Written production and process control procedures are not followed in the execution of production and process control functions. Specifically, 1. You failed to follow your SOP No. 6.020 "Label Control" when you made changes to your labels. You did not do it via change control procedures. 2. You did not follow your SOP No. 1.030 "Change Control" when a change was made to cease manufacturing operations for your Tropicamide 0.2% Cyclopentolate 0.2% Phenylephrine 0.5% Ketorolac 0.1% Lidocaine Jelly 0.4%. Your NOE 2018-659, initiated on 9/12/17, identified the decision to cease manufacturing operations for this product occurred on 4/4/17, but no documentation was generated to support this decision. 3. You failed to follow your SOP no. 5.020 "Customer Complaints" where you did not conduct an investigation for Complaint no. 0118-029, initiated on 1/19/2018 for Mitomycin lot no. C274-000003188, for the presence of a black particle. 4. You did not follow your SOP No. 9.200 "Visual Inspection and Defect Recognition" for Avastin 2.5 mg/0.1 mL Ophthalmic Solution lot no. C274-000004947. You did not perform a visual inspection of your retain samples and did not include a review of these samples as a part of the investigation reported in DEV-2018-042 initiated on 6/27/18. 5. You did not follow your SOP no. 5.110 "Adverse Drug Experiences" as you did not submit adverse drug experience reports for unexpected adverse drug experiences received for your compounded sterile drug products. 6. You did not follow your SOP No. 1.030 "Change Control" when you made changes to the manufacturing codes affected as a result of your change to the (b)(4) software system in April 2017. This change affected a number of things (to include but not limited to) such as the format of the batch records, finish product labels, and the invoice layout for JCB invoices to the customer.
- Observation 9
Incomplete environmental monitoring program
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, In your environmental monitoring program, your SOP no. 3.020 "Environmental Monitoring" does not include information on all the equipment located in your sterile core. In your Environmental monitoring program, you do not account for all equipment in your aseptic core to assure appropriate monitoring is performed. Repeat Observation from 11/16-12/3/15 EI Inspections
- Observation 10
Incorrect or incomplete product labeling
The labels used on your compounded drug products are incorrect as follows: Specifically, A. Currently the label states "FDA.gov/medwatch or 1-800-FDA-1088" which is not the web address given in section 503B(a)(10)(B)(ii) and does not take the user directly to FDA's MedWatch page. B. Currently the label states "sterile solution for injection" or "solution for injection" and does not include the type of injection (e.g., "epidural" for betamethasone sodium phosphate injection, dexamethasone sodium phosphate injection, methylprednisolone acetate injection, and triamcinolone acetonide injection; "retrobulbar" for bupivacaine/lidocaine injection; "intraocular" for epinephrine injection and lidocaine/phenylephrine injection; [illegible] for sodium citrate containing gentamicin injection, sodium citrate injection, and sodium thiosulfate injection).
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing and instructions and testing .
- FDCA 503B(a)(10)
Container label, outsourcer facility
The container labels of your outsourcing facility?s drug products are deficient.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality and purity.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004839646 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004839646. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.