P.A. Benjamin Manufacturing Company Limited

95-97 East Street, Kingston, Jamaica

FEI 3004341688

FDA has one inspection on file for P.A. Benjamin Manufacturing Company Limited in Kingston, Jamaica (FEI 3004341688). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 16 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

1 import refusal is filed under this FEI, on . FDA’s Red Lists for Import Alerts 66-40 and 66-41 name this firm at this address. FDA printed no FEI on the entries. No court action is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2012
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Import refusals
1 refusal
Import alerts
66-40, 66-41Red List
Matched on FDA’s firm name and street address

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. Quarantine of Rejected Components et. al.

      Rejected components and closures are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

    3. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    4. Investigations made into any unexplained discrepancy

      Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.

    5. Actual yield, % of theoretical yield

      The batch production and control records do not include a statement of the actual yield and percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.

    Show 11 more citations
    1. Written procedures lacking for use of pesticides etc.

      Written procedures are lacking for the use of fumigating agents designed to prevent the contamination of equipment and components.

    2. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

    3. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

    4. Dates not included for each significant step

      Batch production and control records do not include dates of each significant step in the manufacture, processing, and packing of the batch for each batch of drug product produced.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    6. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not independently checked, dated, and signed by a second person.

    7. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.

    8. Reprocessing/quality control unit

      Reprocessing was performed without the review and approval of the quality control unit.

    9. Authority lacking to review records, investigate errors

      The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.

    10. Labeling control records including specimens or copies

      Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.

    11. Quality control unit review of records

      Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 12

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004341688, one row per refused product line.

1 refusal on 2019-11-14 · charged NOT LISTED on 1, DIRECTIONS on 1 · no FDA sample analysis

FDA firm profile
  • 2019-11-14

    MAGNESIUM CARBONATE (ANTACID)60SBL13

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsKL1-0239012-9/11/1B

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-41Red ListDetention Without Physical Examination of Unapproved New Drugs Promoted In The U.S.Import alert pageAlert on fda.gov

    Date published 2016-07-01

    FDA’s entry
    P.A. Benjamin Manufacturing Company Limited · 95-97 East Street, Kingston, JM-01 JAMAICA
    FDA’s inspection record for FEI 3004341688
    P.A. Benjamin Manufacturing Company Limited · 95-97 East Street, Kingston, Jamaica

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    10 products

    • 31 K - - --Tea
    • 31 K - - --Tea
    • 31 K - - --Tea
    Show 7 more products
    • 31 K - - --Tea
    • 31 K - - --Tea
    • 54 E - - 52Kava Kava (Herbal & Botanical Teas)
    • 54 E - - 52Kava Kava (Herbal & Botanical Teas)
    • 54 E - - 52Kava Kava (Herbal & Botanical Teas)
    • 54 E - - 52Kava Kava (Herbal & Botanical Teas)
    • 54 E - - 52Kava Kava (Herbal & Botanical Teas)
  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2012-08-29

    FDA’s entry
    P.A. Benjamin Manufacturing Company Limited · 95-97 East Street, Kingston, JM-01 JAMAICA
    FDA’s inspection record for FEI 3004341688
    P.A. Benjamin Manufacturing Company Limited · 95-97 East Street, Kingston, Jamaica

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    9 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    Show 6 more products
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004341688 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004341688. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.