Skip to content

Pharmaceutical Laboratories and Consultants, Inc.

1010 W Fullerton Ave Ste H, Addison, Illinois, United States

FEI 3003982646

FDA has 4 inspections on file for Pharmaceutical Laboratories and Consultants, Inc. in Addison, Illinois (FEI 3003982646), from 2009 to 2017. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.160(b) and 21 CFR 211.160(b)(4).

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2009–2017
1 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
2 of 4
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Written procedures lacking for use of pesticides etc.

      Written procedures are lacking for the use of cleaning and sanitizing agents designed to prevent the contamination of equipment.

    4. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    5. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    Show 3 more citations
    1. Deviations from laboratory control requirements

      Deviations from written test procedures and laboratory mechanisms are not recorded and justified.

    2. Calibration - at intervals, written program, remedial action

      The calibration of instruments, apparatus, gauges and recording devices is not done at suitable intervals.

    3. Adequate lab facilities not available

      Adequate lab facilities for testing and approval or rejection of components and drug products are not available to the quality control unit.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration - at intervals, written program, remedial action

      The calibration of instruments and recording devices is not done at suitable intervals in accordance with an established written program.

    2. Records not made readily available to FDA

      Records associated with drug product control and within the retention period for such records, were not made readily available for authorized inspection.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    4. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

    5. Complete Test Data

      Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.

    Show 4 more citations
    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    4. Inadequate number of personnel

      The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, and holding of each drug product.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003982646 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003982646. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.