Biocon Biologics Limited
Block No, B1,B2, B3, B5, Q13 Of Q1 And W20 & Unit S18,1st Floor, Block B4, Sez, Plot No.2,3,4&5, Phase Iv, Bommasandra-Jigani Link Road, Bengaluru, India
FEI 3003981475DUNS 650501997
Company: Biocon Biologics Limited · Linked by exact D-U-N-S match (860350848) in FDA registration data
FDA has 11 inspections on file for Biocon Biologics Limited in Bengaluru, India (FEI 3003981475), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent has not read its observations yet; the PDF has them. One of the 10 FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Aug 26, 2022. 1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Biocon Biologics Limited (D-U-N-S 860350848), has registered 2 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 11, 2009–2024
- 1 OAI · 8 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 11
- 2 PDFs not read yet · 3 posted 483s not matched to an inspection
- Requested under FOIA
- 10 requests, latest FY2023
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Theoretical yield statement including percentages
Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Disinfection efficacy not demonstrated
Disinfection efficacy is incomplete or not adequately demonstrated, specifically: A. Efficacy study BF/STY/001/P (effective 14NOV2017) using sporicidal disinfectant completed for the Filling and Finish Area did not demonstrate effectiveness in controlling potential microbial contamination showing a minimum log bioburden reduction. In addition, after [illegible] a level of less than [illegible] ppm residual of [illegible] was not confirmed. B. In Disinfection efficacy study performed per protocol BF/QCQ8/STY/P/313 the disinfectants were applied by spraying a thin layer of disinfectant directly on to coupons, and waiting for the specified residence times of [illegible] before the efficacy log reduction was demonstrated. However, to clean production areas the disinfectant agent is applied using mops for ceilings, walls and floors and sprayed on lint free cloth and wiped on equipment.
- Observation 2
Missing environmental monitoring for open operations
Environmental monitoring is deficient. Specifically, Microbial environmental monitoring is not conducted for open operations conducted for drug product formulation preparation, compounding and in LAF-026 located in the formulation room (Grade C).
Show observations 3 to 7
- Observation 3
Inadequate glassware cleaning procedures
Cleaning procedures are inadequate, specifically: During the observation of manual glassware cleaning in Grade D washroom F072 all product contact surfaces were not exposed to the cleaning agent. Glassware was not filled to the [illegible] as stated in procedure BF/FM/SOP/019 version 4. Cleaning of the glassware lids were not included in the cleaning procedure and were not exposed to the cleaning agent.
- Observation 4
Poor handling during raw material dispensing
Inadequate behaviors to prevent contamination of raw materials were observed during the dispensing of raw materials for [illegible] formulation [illegible], specifically: A. Dispensing operator cleaned the floor in front of the balances inside the hood with a sprayed wipe and did not change gloves or sanitize gloves before resuming dispensing activities. B. Raw material containers were not wiped down with any sanitizing agent prior to entering dispensing hood. C. After weighing, balance was cleaned with a [illegible] wipe and then the same wipe was used to clean the table surrounding the balance. D. The raw material was inside material entry/exit [illegible], stored inside a battered cardboard box inside a [illegible] bag, [illegible] bag and inner [illegible] bag. The material was taken out of the cardboard box and placed inside a [illegible] bin before entering the dispensing booth. This material specification contains and endotoxin limits.
- Observation 5
Dispensing procedure lacks QC sampling
Operating procedure for dispensing of [illegible] for manufacturing purposes does not reflect Quality Control sampling procedure for the routine monitoring of the system. Specifically, ~ a (b) (4) SOP CQC M/SOP007 version 4.0 states to open the sample valve [illegible] and let the [illegible] flow for [illegible] and then the [illegible] flow to permit filling of the sample flasks/bottles. Procedure BF/FM/SOP/070, Operation of [illegible] Mobile Tank [illegible] Fill Finish, version 4.0 does not require any dispensing into the tank.
- Observation 6
Inadequate trending and analysis
Inadequate Trending analysis to identify potential issues that could impact product quality. Specifically: A. Temperature controlled warehouse storage area WH033 which stores raw materials used in the formulation had temperature excursions above 25°C on April 18, 19 and 20, 2018. The temperature control range is 18 to 25°C. - April 18, intermittent excursions above 25°C, with the longest period 15:56 to 18:46 (2 hours 50 min) with a maximum temperature of 25.3°C - April 19, excursions above 25°C were from 15:26 to 19:26 (4 hours) with a maximum temperature of 25.3°C - April 20, excursions above 25°C were from 14:26 to 18:46 (4 hours 20 min) with a maximum temperature of 26.1°C No analysis for potential impact to materials stored in the warehouse was performed for these temperature excursions. B. The trend review of microbiological and chemical analysis data for [illegible] does not include analysis of any bacterial endotoxin data. C. Trend summaries for Environmental Bioburden Monitoring or Fill Finish, Trend for Out of Specification for [illegible] and Formulations for [illegible]; Corrective Action Preventative Action Overview for the period [illegible] do not trend for root cause.
- Observation 7
Insufficient equipment qualification/verification
Inadequate equipment qualification/verification based on the documents provided. Specifically, A. Cleaning verification executed per BF/QA/STY/P/105, effective 21SEP2015 for direct product contact parts did not include glassware lids, which are potentially product contact. In addition, retrospective verification of personnel involvement in the manual cleaning procedure from July 2017 was provided. No documentation was provided to show that personnel were trained in the manual cleaning procedure prior to protocol execution. B. Operational Qualification ETPL_EQDF_SI-810-004_V00.1, effective 23May2017, of balance (Equipment ID: W20-WB-07) did not include correct functional verification of the final package product weight check ranges using green light (acceptable) or red light (not acceptable) functionality. C. There is no data to support that the line is sufficient to remove other residual [illegible] syringe filling. The [illegible] and [illegible] share the same supply line for the syringe filler.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate investigation of particulates
Observation 1 Investigations of an unexplained discrepancy did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy. A. Inadequate investigation into visible particulates observed in | Injection, mg/ml. Since August 2015, the firm has observed particles in both long term and accelerated conditions. This material continues to be sold in Uruguay, Russia and Dominican Republic and has a [illegible] B. No risk assessment has been performed after the following updates to determine how the previous versions of these documents affected product on the market: * BF/QC/SOP/003 Microbiological Monitoring for Controlled Environment for, and QC Laboratory. This procedure was updated to include monitoring finger dabs set-up to grade A limits, dated 23 May 2017. * BF/QA/SOP/002 Aseptic Process Simulation Strategy, effective 24 May 2017 for the addition of the review of media fills. * QC/SOP/042 Data Handling Systems Management, dated 22 May 2017, changed from reviewed audit trail to reviewing audit trail.
- Observation 2
Inadequate aseptic/sterilization validation
Observation 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. A. Aseptic personnel are not tracked. Currently personnel who pass gowning qualification are allowed into the aseptic area regardless of whether they participated in a media fill. B. There are no requirements for qualifying personnel during media fills. Activities performed during a media fill are tracked on a media fill tracking sheet since April 2017. There are no requirements specified in BF/FM/STY/P/171 Protocol for Qualification of Operators for Filling Operation for what duties need to be performed by operators to qualify them during a media fill. Management stated they are currently gathering data on what activities the operators are performing and will be setting requirements in the future. C. Filling times are not tracked during media fills. Only the initial start and stop times are documented. This reported time includes shut down periods where the vials are removed from the line and personnel leave the room. Shut down times are not documented. D. The test, used to analyze sterile gloves, has not been validated. E. BF/EM/SOP/069 Procedure for HVAC Validation & Requalification of aseptic areas does not take into account microbial levels in the room.
Show observations 3 to 10
- Observation 3
Deficient environmental monitoring system
Observation 3 Aseptic processing area are deficient regarding the system for monitoring environmental conditions. A. Aseptic operators are held to grade B qualifications even though they work in grade A areas. B. Only testing gloves for grade A specifications set-up of the filling areas. The rest of the personnel monitoring is held to B specifications set-up. C. Not specifying locations for environmental monitoring. Various locations were noted for location during the review of videos and documentation. D. BF/QC/SOP/003 Microbiological Monitoring of Controlled Environments for and QC Lab, v10, dated 23 May 2017, was not being followed for swab sampling. This was noted during a review of a video of vial filling and was confirmed by microbiological management. E. Particle counter is located away from filling in the PFS syringe filling area.
- Observation 4
Failure to follow aseptic procedures
Observation 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. A. tank bioburden samples are taken The firm lacks scientific rationale for not taking and testing bioburden samples [illegible] step. B. The firm routinely performs or disinfection of the cleanroom facility. However, disinfectant validation was not conducted inside the intended cleanroom; rather, validation was conducted in the general microbiology and the water testing rooms. The firm lacks scientific justification to conclude the validated disinfection effectiveness can be extrapolated or can be achieved when [illegible] is carried out in the cleanroom. C. Cleanroom garments are kept and reused for a specified amount of time according to SOP MM/MC/SOP/003. For example, garments used in the Grade B cleanroom areas are disposed of after [illegible] use and reuse. The firm does not track and reconcile cleanroom garments that are expired or are at the end of use. There are no documented disposal records to assure all expired cleanroom garments are removed from circulation. D. Media plates incubated at dual temperature condition are used to capture both bacterial and fungal contaminants on the plates in EM, PM, and bioburden samples. The firm’s dual temperature validation study is inadequate in that during the validation, bacterial species and fungal species was tested separately. They are not being tested together as a mixture of both organisms on the plate to mimic the actual use conditions. E. All interventions are not being documented during sterile filling. This was noted during the review of CCTV videos obtained during the sterile filling of [illegible] and vials. (b)(4) F. Not following BF/FM/SOP/007 Transfer of Dispensed Materials to Respective Areas during the aseptic filling of lot dated 23 May 2017. G. BF/FM/SOP/180 Aseptic Behavior procedure; v03. dated 27 May 2017 was not being followed during the review of CCTV videos, on the vial filling of batch [illegible] and filling of [illegible]. + Using the same lot during the entire length of production. + Banging on window in Grade A area. * Touching of the filling machine currently not being used during vial filling. « Picking up a cloth from the floor.
- Observation 5
Incomplete laboratory data and records
Observation 5 Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. A. Electronic data from chromatographic analysis is not available prior to 2010, this affects the application data submitted in support of [illegible] Injection, [illegible] mg/ml equivalent base [illegible] and the method validation in support of Injection [illegible] mg/vial. B. Not all laboratory data were recorded accordingly. On 05/25/2017 a FDA microbiologist observed the following: a. The firm’s microbiologist read the settling plate at location Vial Sealing Area Passive on 05/24/2017 and reported "0" CFU. A FDA microbiologist observed 1 CFU for the same plate. b. The firm’s microbiologist read Grade B finger dabs of employee - Left hand on 05/24/2017 and reported "0" CFU. A FDA microbiologist observed 1 CFU for the same plate. c. The firm’s microbiologist read Grade B finger dabs of employee - Right hand on 05/24/2017 and reported "0" CFU. A FDA microbiologist observed 1 CFU for the same plate. C. Aseptic filling operators are monitored upon the cleanroom facility. However, aseptic area records and personnel monitoring (PM) plates collected cannot always be reconciled. On 05/25/2017, we reviewed logbook records from 05/20/2017 to 05/24/2017 and observed the following: a. On 05/23/2017, aseptic operator [illegible] without documented [illegible] the vial filling area at [illegible], and was missing a set of personnel monitoring plates that were documented to have been collected on 05/23/2017. b. On 05/22/2017 operators [illegible] and on 05/23/2017 operator [illegible] with neither records nor records for the vial filling area had their PM plates collected and incubated. c. On 05/20/2017 operators [illegible] and on 05/22/2017 operators [illegible] and on 05/24/2017 operators [illegible] had documented the vial filling area but did not have documented records that their PM plates were collected and incubated. D. The audit trail could not be provided in a usable format for the data obtained from the Agilent - OpenLab HPLCs in laboratory Q8 and Agilent - OpenLab HPLCs in laboratory Q13. E. Quality Unit signs as verifying the interventions performed during media fills. This activity is not performed contemporaneously. Instead, Quality watches filling activities for the duration of the [illegible] from a window in an adjoining room. At the end of the [illegible] Quality personnel enter the filling area and signs off on any interventions performed during the [illegible]. Management admitted the times and actual number of interventions performed is not verified. F. Raw data from the leak testing of sterile gloves is not documented. G. Due to the data provided to the QC analyst upon receipt, the description test required by the sterile glove specification cannot be performed. This test has been listed as "complies" for all gloves received. H. Procedure for Usage of Technical Information Sheet procedure does not following for EM samples and signing that the EM collected during media fill were documented as "pass" even though the following investigations were initiated and had yet to be closed; BF/00S-02/M/16/030, BF/OOT/16/054, BF/00S-02/M/16/031, BF/00S-02/M/16/029, BF/OOT/16/053.
- Observation 6
Deficient cleaning and disinfectant validation
Observation 6 Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. A. The disinfectant efficacy study for [illegible] for the organism cladosporium oxysporum was inadequate due to conflicting results being reported and an erroneous conclusions being reported. The organism was found during an OOS investigation into failed EM results obtained during a media fill for filling of sterile syringes in August 2016. The firm delayed executing the study until February 2017. The investigation determined the current hold time of [illegible] for [illegible] is inadequate and a minimum of [illegible] is needed, however the cleaning method has yet to be updated with this information. B. Cleaning of the spray bottles used during sterile filling is not documented. According to COA the bottles can be used [illegible] times. These spray bottles are not being tracked and the number of times the bottles are [illegible] is not documented. C. BF/FM/SOP.091 Cleaning of Aseptic Area Fill Finish procedure is not being followed. This was observed during the review of video for vial filling of batch dated 24 May 2017, and watching cleaning during the inspection. For example, cleaning with one cloth for the majority of the cleaning, and not cleaning in a unidirectional manner. D. The firm has not sufficiently established the efficacy of disinfectants used in the aseptic processing areas, specifically: a. [illegible] are used to clean filling machine surfaces. However, only [illegible] machine surface had been challenged using the above disinfectants. The firm lacks scientific rationale for not challenging other representative machine surfaces, such as [illegible] machine [illegible] conveyor belt and [illegible] transport wheels. b. [illegible] are used to disinfect cleanroom surfaces. However, only [illegible] surfaces such as cleanroom floors had been challenged with the above disinfectants using standard microorganisms and environmental isolates. The firm lacks scientific rationale for not adequately challenging other manufacturing surfaces, such as panels (ceilings), glass (light fixture covers), and [illegible] (wall panels).
- Observation 7
Quality unit lacks approval authority
Observation 7 The quality control unit lacks the responsibility-and authority to approve and reject all components and drug products. Specifically, A. BR/QA/SOP/039 Vendor Qualification procedure, v02, dated 30 December 2016, is not being followed for the supplier of sterile gloves. B. Glove specifications do not include evaluation of the outer packaging. C. The sample size of sterile gloves it not statistically representative. The firm samples [illegible] gloves from receiving, regardless of how many gloves are received. Receiving have varied from [illegible] to [illegible] pairs of gloves. D. During the review of the SAP system, [illegible] of injection [illegible] ng/ml, lot [illegible] was in unrestricted use. This lot expired in January 2017.
- Observation 8
Insufficient staff training and qualifications
Observation 8 Employees engaged in the manufacture and processing of a drug product lack the training and experience required to perform their assigned functions. A. Colony growth on environmental monitoring (EM) and personnel monitoring (PM) plates are not always enumerated correctly. The firm lacks documented training or qualification program for conducting colony enumeration. On 05/25/2017 a FDA microbiologist observed the following, a. The firm reported CFUs in 9 out of the total EM and PM plates read on 05/24/2017. A FDA microbiologist observed additional CFUs that were missed by the firm’s microbiologist in 6 out of the same 9 plates. The observed additional CFUs were confirmed by the firm’s management. b. The firm reported CFUs in 17 out of the total EM and PM plates read on 05/23/2017. A FDA microbiologist observed additional CFUs that were missed by the firm’s microbiologist in 10 out of the same 17 plates. The observed additional CFUs were confirmed by the firm’s management. B. There is a lack of documented CGMP training for IT personnel engage in the manufacture and processing of drug products. For example, IT personnel with administrator rights to the firm’s HPLC, GC, UV, and IR computer systems do not have documented CGMP trainings.
- Observation 9
Deficient bacterial endotoxin testing
Observation 9 Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. The firm’s bacterial endotoxin test for the finished product is deficient. A. Bacterial endotoxin test (BET) method for the finished product is deficient in that it fails to adjust for the Maximum Valid Dilution (MVD) of [illegible] sample such that it can lead to false negative results. GAM: QC/GAM/030, version 003, "Bacterial Endotoxin Test" MVD calculation method is based on unit of finished product and does not accurately reflect the MVD for the [illegible] of finished products used in validations as well as in the routine bacterial endotoxin testing. B. Only the pH of the samples, not pH of the sample-lysate mixture is measured as per USP requirement.
- Observation 10
Labeling control procedures not followed
Observation 10 Procedures describing in sufficient detail the controls employed for the issuance of labeling are not followed. Procedure was not followed in the destruction of secondary packing material. Specifically, on 05/29/2017 during the labeling and packaging of Batch: rejected labels bearing batch code, manufacture date, and expiry date were found in an unsecured waste bin. SOP BF/FM/SOP/076, "Precautions For Packing", version 04 states rejected packing materials must be placed in labeled and closed containers with lock and key.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
10 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Jul 26, 2024VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Sep 4, 2024FDA-FOIA-2024-7839Form 483Closed
Inspection ending Aug 26, 2022OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- FY2023FDA-FOIA-2022-8260Form 483Closed
Inspection ending Aug 11, 2022
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Sep 1, 2022FDA-FOIA-2022-6342Form 483Closed
Inspection ending Aug 30, 2019VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Nov 28, 2023FDA-FOIA-2023-10629Form 483Withdrawn
Inspection ending Jun 16, 2015VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Feb 18, 2021FDA-FOIA-2021-1112Form 483Withdrawn
Inspection date not given
5 requests. FDA released records in answer to a request for its Inspection records on Sep 16, 2026. FDAgent holds no copy that FDA posted.
- Jul 14, 2026FDA-FOIA-2026-6678Inspection recordsRecords released
- Aug 27, 2024FDA-FOIA-2024-7536Form 483Closed
- Mar 1, 2021FDA-FOIA-2021-1313Form 483· 1 of 2 sitesClosed
- Mar 1, 2021FDA-FOIA-2021-1312EIR· 1 of 2 sitesClosed
- Feb 18, 2021FDA-FOIA-2021-1103EIRWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 11 inspections.
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003981475, one row per refused product line.
1 refusal on 2021-09-17 · charged AGR RX on 1 · no FDA sample analysis
FDA firm profile- 2021-09-17
ETANERCEPT61YIA03
AGR RX 801(d)(1),(2); IMPORTATION RESTRICTED
Division of Northeast Imports97X-0045017-0/11/2
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Biocon Biologics LimitedD-U-N-S 860350848
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Biocon Biologics Limited (D-U-N-S 860350848) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Biocon Biologics LimitedBengaluru, India · FEI 30152832452 inspections2latestSep 3, 2025VAINone on file
- BIOCON SDN.BHD.Iskandar Puteri, Malaysia · FEI 30112482481 inspection1latestSep 27, 2024VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003981475 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003981475. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.