Modern Surgical Inc
312 W Canal Dr, Gulf Shores, Alabama, United States
FEI 3003947239
FDA has 3 inspections on file for Modern Surgical Inc in Gulf Shores, Alabama (FEI 3003947239), from 2008 to 2012. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Dec 11, 2008. No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 1271.260(e).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 3, 2008–2012
- 1 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of Written MDR Procedures
Written MDR procedures have not been developed and maintained.
Storage temperatures recorded, maintained
Storage temperatures of HCT/Ps were not recorded and maintained.
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Contamination, mix ups, improper release
Storage areas and stock rooms were not controlled to prevent HCT/Ps from improperly being made available for distribution.
Records incomplete
Records did not identify the person performing the work, did not show the dates of entries, and were not detailed as necessary to provide a complete history of work performed.
Evaluation--microorganisms, damage
Incoming HCT/Ps were not inspected for damage and contamination.
Documenting disposition of each HCT/P
A method has not been followed and reviewed in the tracking system to document the disposition of each HCT/P and to permit the prompt identification of the consignee of the HCT/P, if any.
Quality audits performed periodically
Periodic quality audits of activities related to core CGTP requirements have not been performed.
Show 1 more citation
Storage temperatures recorded, maintained
Storage temperatures of HCT/Ps were not recorded and maintained.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 1271.260Storage2 of 2
- 21 CFR 803.17What are the requirements for developing, maintaining, and implementing written MDR procedures that apply to me?1 of 2
- 21 CFR 1271.160Establishment and maintenance of a quality program1 of 2
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P1 of 2
- 21 CFR 1271.270Records1 of 2
- 21 CFR 1271.290Tracking1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003947239 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003947239. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.