Catalent Anagni SRL
Fontana Del Ceraso, Strada Provinciale 12 Casalina 41, Anagni, Italy
FEI 3002806546DUNS 440438790
Company: Novo Nordisk Production Belgium SA · Linked by exact D-U-N-S match (370696762) in FDA registration data
FDA has 8 inspections on file for Catalent Anagni SRL in Anagni, Italy (FEI 3002806546), from 2011 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Novo Nordisk Production Belgium SA (D-U-N-S 370696762), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 8, 2011–2026
- 0 OAI · 7 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 8
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Nov 8, 2024
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
Equipment for Environmental Control
Equipment for adequate control over humidity is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Show 1 more citation
Buildings not maintained in good state of repair
Buildings used in the processing and holding of a drug product are not maintained in a good state of repair.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Nov 8, 2024.
Inspection ending Jul 16, 2024
3 requests. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Nov 8, 2024FDA-FOIA-2024-9917EIRNo records found
- Oct 24, 2024FDA-FOIA-2024-9419EIRWithdrawn
- Oct 18, 2024FDA-FOIA-2024-9237Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.58Maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002806546, one row per refused product line.
1 refusal on 2020-03-03 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2020-03-03
ANTI-COAGULANT, N.E.C.61LCA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-5733037-4/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Novo Nordisk Production Belgium SAD-U-N-S 370696762
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Novo Nordisk Production Belgium SA (D-U-N-S 370696762) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Novo Nordisk Production Belgium SABrussels, Belgium · FEI 300764700012 inspections12latestApr 7, 2023VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002806546 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002806546. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.