QuVa Pharma, Inc.
5920 S General Bruce Dr Ste 100, Temple, Texas, United States
FEI 3002468086
FDA has 6 inspections on file for QuVa Pharma, Inc. in Temple, Texas (FEI 3002468086), from 2014 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
The most recent OAI inspection ended on Mar 14, 2019. No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.42(c)(10)(iv) and 21 CFR 211.42(c)(10)(v).
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2014–2022
- 3 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 6
- 6 posted 483s not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
input/output verification
Input to and output from the computer and records or data are not checked for accuracy.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that floors are not smooth and/or hard surfaces that are easily cleanable.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing and instructions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Missing component receipt procedures
Written procedures are lacking which describe in sufficient detail the receipt, identification, approval, and rejection of components. Specifically, your firm is using non-pharmaceutical grade components in the formulation of sterile drug products. For example, a) Your firm uses [(b)(4)] for adjusting the pH of sterile drug products. The [(b)(4)] is labeled "NOT FOR DRUG, FOOD, OR HOUSEHOLD USE". b) Your firm uses [(b)(4)] for adjusting the pH of sterile drug products.
- Observation 2
No validated depyrogenation process
There are no established written methods of cleaning or methods of processing to remove pyrogenic properties. Specifically, your firm has not validated the depyrogenation process for the [(b)(4)] used in compounding sterile drug products. Your firm has not demonstrated that the washing process you have implemented is adequate for endotoxin removal.
Show observations 3 to 9
- Observation 3
Deficient environmental monitoring program
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) In January 2019, your firm removed the [(b)(4)] in all [(b)(4)] ISO 7 Cleanrooms that were [(b)(4)]. As part of the change control, your firm did not perform an assessment to justify how you are bringing the materials into the cleanroom or if any changes were needed to the environmental monitoring program as a result of the change. b) Your firm is not sampling sites that are frequently touched during production such as the surface of the [(b)(4)] Repeater Pump and the door handle from the ISO 7 Cleanroom into the ISO 8 Gowning/Ante Room.
- Observation 4
Cleanroom equipment contamination (rust)
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient. Specifically, rust and residue could be seen on the metal hinges of the totes used to hold and bring items into and out of the ISO 7 Cleanrooms and/or the ISO 8 Gowning/Ante Rooms, including empty sterile bags used for filling the sterilized product into packages containing sterile tubing, [(b)(4)], and environmental monitoring plates; and bags with the [(b)(4)] drug product. Rust was also noted on the wheels of the trash cart in the ISO 7 Cleanroom and the inside of the lid on the trash can in the ISO 8 Gowning/Ante Room for Cleanroom [(b)(4)].
- Observation 5
Inadequate handwashing/gowning procedures
Production personnel were not practicing good sanitation and health habits. Specifically, your firm does not have handwashing facilities near the gowning areas for entry into compounding areas, including entry into ISO 7 Cleanrooms/ISO 5. In addition, your written procedures regarding gowning do not require hand washing.
- Observation 6
Unvalidated incubation conditions
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm has not validated the incubation temperature and time for growth promotion of media and the environmental and personnel monitoring plates. Your firm is incubating the plates at [illegible].
- Observation 7
Compounding copies of approved drugs
You compound drugs that are essentially a copy of one or more approved drugs within the meaning of sections 503B(a)(5) and 503B(d)(2). Specifically, you compound drug products that: a) are identical or nearly identical to an approved drug that is not on the drug shortage list in effect under section 506E at the time of compounding, distribution, and dispensing; or b) are not identical or nearly identical to an approved drug, but contain a bulk drug substance that is also a component of an approved drug, and for which there is no change that produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the compounded drug and the comparable approved drug. Examples of compounded drug products that are essentially a copy of one or more approved drugs include: Neostigmine methylsulfate 1mg/1ml; Glycopyrrolate 0.2mg/ml; Midazolam PF 1mg/ml.
- Observation 8
Missing required label information
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, the following information is not found on your drug product labels: a) The statement "This is a compounded drug"; b) The name, address, and phone number of the outsourcing facility; c) The dosage form and strength; d) The quantity or volume; e) The National Drug Code number, if available; f) The statement "Not for resale", and, if the drug is dispensed or distributed other than pursuant to a prescription for an individual identified patient, the statement "Office Use Only"; g) A list of active and inactive ingredients, identified by established name and the quantity or proportion of each. Examples of your drug product labels that do not contain this information include: Fentanyl 10mcg/mL Preservative Free (PF) 3000mL bag; Morphine Sulfate Pentahydrate 1mg/mL PF 3000mL bag; Fentanyl/Ropivacaine HCL PF 2mcg/ml/0.2% 3000mL bag; Diltiazem HCL 1mg/mL PF 3000mL bag; Amiodarone HCL 1.8mg/mL 3000mL bag.
- Observation 9
Containers missing required info
The containers of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B). Specifically, your containers do not include the following information: a) Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088. Examples of your container labels that do not contain this information include: Fentanyl 10mcg/mL PF 3000mL bag; Morphine Sulfate Pentahydrate 1mg/mL PF 3000mL bag; Fentanyl/Ropivacaine HCL PF 2mcg/ml/0.2% 3000mL bag; Diltiazem HCL 1mg/mL PF 3000mL bag; Amiodarone HCL 1.8mg/mL 3000mL bag. b) Route of administration. Examples of drug product containers that do not contain this information: Fentanyl 10mcg/mL PF 3000mL bag; Morphine Sulfate Pentahydrate 1mg/mL PF 3000mL bag; Fentanyl/Ropivacaine HCL PF 2mcg/ml/0.2% 3000mL bag; Diltiazem HCL 1mg/mL PF 3000mL bag; Amiodarone HCL 1.8mg/mL 3000mL bag.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility’s drug products are deficient.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Show 1 more citation
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features3 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.186Master production and control records1 of 3
- 21 CFR 211.192Production record review1 of 3
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Other FEIs recorded as QuVa Pharma, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
QuVa Pharma, Inc.FEI 3013931875Bloomsbury, New Jersey, United States
Last inspected 2025-04-04OAI
QuVa Pharma, Inc.FEI 3012053582Sugar Land, Texas, United States
Last inspected 2024-10-28VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002468086 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002468086. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.