FDA has 4 inspections on file for PharMEDium Services, LLC in Sugar Land, Texas (FEI 3000717703), from 2010 to 2017. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Oct 24, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 13 observations from the PDF; they are listed below.

FDA has issued 2 warning letters under this FEI, the latest on (CDER). FDA's compliance record also lists one other action under this FEI: Injunction, . No import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.165(a).

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2010–2017
3 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 4
5 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
5 posted
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Quality unit failed to reject products

      The quality control unit lacks the responsibility and authority to reject all drug products. For example, A. The product 0.2% Ropivacaine HCl in 0.9% Sodium Chloride for Injection, lot #1719401958 (Production date: 7/14/17, Expiration date: 8/12/17) passed testing for endotoxin testing on 7/14/17 and was released for distribution. On 7/26/17, your firm discovered that lot #1719401958 had failed testing for endotoxin and was later recalled. B. The product Magnesium Sulfate 2 g (4 mL of 50% Injection) added to 100 mL 5% Dextrose Injection USP, lot #170331498 (Production date: 2/3/17 Expiration: 3/19/17) failed testing for endotoxin. The failure was attributed to the (b)(4). The suitability of the (b)(4) was found acceptable, but in each case, the (b)(4) was re-tested using a new (b)(4) from the same lot with passing results. A nonconformance report was not issued. Lot #170331498 was released for distribution. C. The product Norepinephrine Bitartrate 1 mg/mL 4 mL in 5 mL Ampule, lot #170330111S (Production date: 2/3/17 Expiration: 3/7/17) failed testing for endotoxin. The failure was attributed to the (b)(4). The suitability of the (b)(4) was found acceptable, but in each case, the (b)(4) was re-tested using a new (b)(4) from the same lot with passing results. A nonconformance report was not issued. Lot #170330111S was released for distribution.

    2. Observation 2

      Facility airflow contamination risk

      The flow of components, drug product containers, closures, labeling, in-process materials, drug products through the building is not designed to prevent contamination. Specifically, a dynamic smoke study performed in 3/17 revealed the ingress of air from the unclassified staging area into the ISO 7 pass-in area when the door was open. Your firm performed a (b)(4) of the differential pressure which, to date, has not been verified (deadline 12/31/17). In addition, smoke studies have not been conducted to verify that the (b)(4) of air pressure resolved the issue. Prior to 3/17, dynamic smoke studies evaluating the flow of air between unclassified and classified areas have never been conducted.

    Show observations 3 to 13
    1. Observation 3

      Inadequate aseptic procedures

      Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile. Specifically, A. On 11/27/17, I (CSO Brown) observed that several technicians engaged in aseptic processing did not consistently re-sanitize their gloves to include the wrist after moving from the ISO 7 area to the ISO 5 hood. In addition, technicians failed to sanitize their gloved hands after transferring plastic bags containing tube sets to the ISO 5 hoods. B. On 12/12/2017, (CSO Caballero) observed the firm's compounding technician handle non-sterile paperwork in the cleanroom area and immediately proceed to compound drug product, 1.5 g Vancomycin HCl in 0.9% Sodium Chloride, Lot #173450110S, (b)(4), inside the firm's ISO 5 hood (b)(4) without sanitizing her hands with sterile [illegible].

    2. Observation 4

      Incomplete investigations of failures/recalls

      There is a failure to thoroughly investigate any unexplained discrepancy or failure of a batch, regardless of whether the batch has been distributed, or a failure to expand an investigation to assess other batches that may also be impacted. A. Sterility Testing Review of sterility failures in 2017 revealed that the investigations were incomplete in that: 1) the contaminating microorganism was not identified, and 2) there was no assessment of other lots from the same ISO 5 hood which may have been affected. In each case, the lots were not distributed. For example, 1. Nonconformance #SNC-17-975 dated 11/29/17 documents that "Ropivacaine HCl in 0.9% Sodium Chloride Injection Pumps, lot numbers 172120168S, 1721201568, 172120172S, and 1721201838 failed sterility testing on 3/1/17. The investigation does not include an assessment of the need for additional sampling of other products or increased environmental monitoring to determine potential impact." The related laboratory investigation #SL-2017-003 dated 8/1/17 (QM approval date) documents that no laboratory error occurred during the investigation. 2. Nonconformance #SNC-17-136 dated 10/30/17 documents that 0.2% Ropivacaine HCl in 0.9% Sodium Chloride in OnQ Pump, lot numbers 1703200908 and 1703200985, failed sterility testing on 2/2/17. The investigation does not include an assessment of the need for additional sampling of other products or increased environmental monitoring to determine potential impact. The related laboratory investigation #SL-2017-001 dated 2/15/17 (QM approval date) documents that no laboratory error occurred during the investigation. B. Endotoxin Testing The product 0.5% Ropivacaine HCl 30 mL Total Volume in a 30 mL BD syringe, lot #170690291S failed testing for endotoxin on 3/13/17 (Result: 0.475 EU/mL, Endotoxin limit [illegible] EU/mL). The lot was re-tested with passing results but was not distributed. A root cause was not determined. Since 1/17, your firm has issued Nonconformance Forms for 8 additional lots of drug product which failed to meet specifications for endotoxin. In each case, the product was discarded. However, the investigations remain open. Some examples consist of the following: A. SNC-17-409 dated 3/24/17 (0.25% Ropivacaine in 0.9% Sodium Chloride, lot #170820130S). B. SNC-17-1607 dated 4/27/17 (Ropivacaine HCl 0.5%, lot #1711601258). C. SNC-17-1456 dated 9/22/17 (0.2% Ropivacaine HCl in 0.9% Sodium Chloride 750 mL, lot #1726402078). D. SNC-17-1457 dated 9/25/17 (100 mg/mL Cefazolin Sodium 2 g in Sterile Water for Injection USP, lot #1726501388). C. Environmental Monitoring Since 1/2017, your firm has had over 100 microbial excursions at action level in the ISO 5 hoods for air, surface, and personnel samples. Your firm performed an investigation which concluded that the source of the contamination (i.e. Aspergillus species) was confined to media fill bags obtained from a vendor. However, corrective action has not been implemented. Some examples consist of the following: 1. An "Over the Action Investigation Report" dated 9/21/17 documented that Aspergillus creber and Penicillium decumbens were isolated in routine EM samples in Hood (b)(4). There was no investigation. A total of (b)(4) lots were produced in Hood (b)(4) on 9/21/17 and distributed to consignees. 2. An "Over the Action Investigation Report" dated 9/27/17 documented that Aspergillus creber was isolated in routine EM samples in Hood (b)(4). There was no investigation. A total of (b)(4) lots were produced in Hood (b)(4) on 9/27/17 and distributed to consignees. D. Potency From 1/2017 to the present, your firm reported a total of 289 confirmed OOS results for potency. Review of the "Investigation Report Assignment Log" for 2017 revealed that there was no documentation that the investigations had been closed. However, an investigation into the root cause has not been completed for approximately (b)(4) lots of drug products. For example, the following nonconformance investigations

      Shortened here; the PDF has the full text.

    3. Observation 5

      Hood maintenance impact not assessed

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, review of hood certifications for the period between 1/1/2017 and the present revealed that in at least two cases the vendor responsible for certification documented a HEPA failure (leakage) which was repaired. However, in each case, your firm failed to determine the impact of the leakage on lots of drug products produced in the respective hoods before the failures occurred.

    4. Observation 6

      Inadequate cleaning/disinfectant systems

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Review of disinfectant effectiveness studies revealed multiple failures utilizing disinfectants currently in use. An investigation to determine the root cause was not conducted. B. Your firm is using non-sterile (b)(4) with sterile (b)(4) which are combined to disinfect bag ports and vial tops. The components are prepared in an unclassified area. C. SOP #CPS-301 entitled, "Facility Cleaning" (Effective date: 5/22/17) establishes a (b)(4) minute contact time for the disinfectants used in the facility. The pliers of the disinfectants recommend a (b)(4) minute contact time. Environmental monitoring isolates obtained from the ISO 5 hoods in the last 6 months have revealed the presence of Aspergillus, Cladosporium, and Rhizopus. THIS IS A REPEAT OBSERVATION

    5. Observation 7

      Insufficient particulate monitoring frequency

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, environmental monitoring for non-viable particulates (air) is not performed at sufficient frequencies to represent routine production conditions within the ISO-7 Clean Room or the ISO-5 (b)(4) Laminar Air Flow Hoods. Currently, your firm performs non-viable monitoring of the ISO 5 hoods on a (b)(4) basis.

    6. Observation 8

      Aseptic process validation deficient

      Procedures designed to prevent microbiological contamination of sterile drug products does not include adequate validation of aseptic processing. Specifically, process simulations are deficient in that new operators are not required to complete media fills for specific sub-processes (i.e., (b)(4)) before being released to production.

    7. Observation 9

      Inadequate visual particulate inspection

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, the visual inspection of finished sterile drug products for particulate matter is not performed against a (b)(4) for visualization of various types of particles throughout the filled container. Your firm approved SOP #CP[illegible]-788 entitled, "Visual Inspection" (Approval date: 3/21/17) which includes provision for inspection using a (b)(4). However, the SOP has not been implemented.

    8. Observation 10

      Non-representative product sampling

      Samples taken of drug products for determination of conformance to written specifications are not representative. Regardless of batch size, (b)(4) for sterility and endotoxin testing of all batches, unless the finished dosage unit contains less than (b)(4), in which (b)(4) are pulled. For example: A. Oxytocin 20 Units added to 500 mL 0.9% Sodium Chloride Injection, USP, lot #170200098S (Sample: (b)(4)). B. Magnesium Sulfate 2 g (4 mL of 50% Injection) added to 100 mL 5% Dextrose Injection USP I, lot #170330149S (Sample: (b)(4)). C. 0.2% Ropivacaine HCl in 0.9% Sodium Chloride Injection 400 mL in 400 mL On Q Fixed Primed, lot #171940195S (Sample: (b)(4)).

    9. Observation 11

      Unreviewed electronic laboratory data

      Input to and output from the computer, related systems of formulas, records or data are not checked for accuracy. A. Your firm has no procedure to describe the review of analytical data used for release testing of finished drug products. There is no documented review of electronic raw data or audit trails, to determine, for example, whether product has undergone unauthorized retesting or whether data has been otherwise manipulated. Testing for potency, sterility, and endotoxin is performed on all finished product batches, and all of the testing equipment captures data electronically (e.g., (b)(4), (b)(4) system for endotoxin analysis, and (b)(4) system). SOP CPS-728, Review of Batch Processing Documentation, does not describe any review of analytical data. B. Quality Control laboratory worksheets are issued from an electronic document control system, but are accessible to the analyst for unlimited printing, with no date/time-stamp or other issuance controls for reconciliation against other laboratory data. C. Electronic logs of Quality System reports or files are maintained on uncontrolled spreadsheets on a shared network drive, and there are no controlled paper logs. The electronic spreadsheets do not have an audit trail function to show if previously entered items have been altered or deleted. Logs for the following items are stored in this manner: Notice of Event (NOE) reports, Non-Conformance Reports (NCRs), Laboratory Out-Of-Limit or Out-Of-Specification (OOL/OOS) reports, and Corrective and Preventive Action (CAPA) reports.

    10. Observation 12

      Labels missing required information

      1. The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, The following information is not found on your drug product labels: a) The date that the drug was compounded. b) A list of active and inactive ingredients, identified by established name and the quantity or proportion of each ingredient. Examples of drug product labels that do not contain this information include: • Oxytocin 30 units added to 500 mL 0.9% Sodium Chloride Injection USP (503 mL total volume) • Norepinephrine Bitartrate 4 mg added to 250 mL 0.9% Sodium Chloride Injection USP (16 mcg per mL) (254.00 mL total volume) • EPINEPHrine HCl 4 mg added to 250 mL 5% Dextrose Injection USP (16 mcg per mL) (254.00 mL total volume) • Magnesium Sulfate 2 g (4 mL of 50% Injection) added to 50 mL 0.9% Sodium Chloride Injection USP (54.00 mL total volume) • Diltiazem HCl 125 mg in 125 mL 0.9% Sodium Chloride Injection USP (1 mg per mL) • Calcium Gluconate 1 g (10 mg per mL) in Dextrose 5% (100 mL total volume in a 150 mL Intravia bag) • 0.2% Ropivacaine HCl in 0.9% Sodium Chloride (60 mL total volume in 60 mL BD Syringe) • Phenylephrine HCl 20 mg added to 250 mL 0.9% Sodium Chloride Injection USP (80 mcg per mL) (252.00 mL total volume) • Heparin Sodium Injection USP 25,000 USP Units added to 250 mL 0.9% Sodium Chloride Injection USP (100 units per mL) (255.00 mL total volume) • Vasopressin 50 units added to 50 mL 0.9% Sodium Chloride Injection USP (1 unit per mL) (50.50 mL total volume) • Sodium Phosphate added to 0.9% Sodium Chloride 15 mMol 250 mL bag (255.00 mL total volume) • Oxytocin 20 units added to 1000 mL 0.9% Sodium Chloride Injection USP (1002.00 mL total volume) • Oxytocin 40 units added to 1000 mL 0.9% Sodium Chloride Injection USP (1004.00 mL total volume) • Magnesium Sulfate 2 g (4 mL of 50% Injection) added to 50 mL 5% Dextrose Injection USP (54.00 mL total volume) • 0.25% Bupivacaine HCl in 0.9% Sodium Chloride Injection (500 mL total volume in an ON-Q Pump) THIS IS A REPEAT OBSERVATION

    11. Observation 13

      Failed to report compounded products

      Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the December 1, 2016, through May 31, 2017, reporting period as required by section 503B(b)(2)(A). Specifically, the following products were compounded and not identified on your June 2017 report: • 10 mEq Potassium Chloride and 10 mg Lidocaine added to 0.9% Sodium Chloride • 20 mEq Potassium Chloride and 10 mg Lidocaine added to 5% Dextrose

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    4. FDCA 503B(a)(10)

      Drug product label, outsourcer facility

      The labels of your outsourcing facility's drug products are deficient.

    5. Labeling Control Records and Label Copies

      The batch production and control records are deficient in that they do not include specimen and copy of labeling.

    Show 2 more citations
    1. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

  7. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    4. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    5. Retention time of reserve samples, in general

      Reserve samples for drug products are not retained for one year after the expiration date of the drug product.

    Show 4 more citations
    1. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    3. Test methods

      The accuracy and sensitivity of test methods have not been established.

    4. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.

Show all 11

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • InjunctionCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3000717703 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3000717703. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.