LA Labs
7334 Hollister Ave Ste H, Goleta, California, United States
FEI 3000717579
FDA has 5 inspections on file for LA Labs in Goleta, California (FEI 3000717579), from 2010 to 2015. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2010–2015
- 0 OAI · 2 VAI · 3 NAI
- Inspections with 483 observations shown
- 1 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Quality control unit review of records
Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.
Sterility/pyrogens - test methods written, followed
Test procedures relative to appropriate laboratory testing for sterility are not followed.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Show 7 more citations
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Status of Each Lot Identified
Each lot of components was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Stability testing records not included
Laboratory records do not include complete records of all stability testing performed.
Certificates of Testing (Containers, Closures)
Certificates of testing of containers and closures are accepted in lieu of testing without establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals.
Controlled release test methods written, followed
Test procedures describing the testing of controlled release dosage form drug product are not written.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not retained.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 5 inspections.
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.103Calculation of yield1 of 1
- 21 CFR 211.105Equipment identification1 of 1
- 21 CFR 211.142Warehousing procedures1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.167Special testing requirements1 of 1
- 21 CFR 211.170Reserve samples1 of 1
Show all 10
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.194Laboratory records1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000717579 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000717579. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.