Plainview Hospital
888 Old Country Rd, Plainview, New York, United States
FEI 2470872
FDA has 3 inspections on file for Plainview Hospital in Plainview, New York (FEI 2470872), from 2010 to 2014. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 8 citations from this inspection. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 606.160(a)(1), 21 CFR 606.100(b) and 21 CFR 606.60(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2010–2014
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the collection, processing, compatibility testing, storage, and distribution of each unit of blood and blood components so that all steps can be clearly traced.
Determination of lot numbers and supplies
Appropriate records are not available to determine the lot numbers of supplies used for specific units of the final product.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Storage temps./agitation
Failure to store platelets immediately after resuspension at 20 to 24 degrees Celsius with continuous gentle agitation.
Legibility and indelibility
Records are not indelible.
Show 3 more citations
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection, processing, storage, and distribution of blood and blood components for homologous transfusion and autologous transfusion are not always maintained and followed.
Maintain and clean equipment
Failure to maintain equipment used in the storage and distribution of blood and blood products in a clean and orderly manner and so as to facilitate cleaning and maintenance.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the collection of each unit of blood and blood components so that all steps can be clearly traced.
Assignment of donor number
Failure of records describing the history and ultimate disposition of blood products to include a donor number assigned to each accepted donor, which relates to the unit of blood collected from that donor, and which relates to the donor's medical record.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and distribution of blood and blood components for homologous transfusion and autologous transfusion are not always maintained and followed.
Maintain and clean equipment
Failure to maintain equipment used in the processing of blood and blood products in a clean and orderly manner.
Labeling procedures to avoid labeling mix-ups
The standard operating procedure fails to include a written description of the labeling procedures and include safeguards to avoid labeling mix-ups.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Record review prior to release
All records pertinent to a lot or unit were not reviewed before the release or distribution of a lot or unit of final product.
Person performing, test results, interpretation
Records fail to include dates of the various entries so as to provide a complete history of the work performed.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures3 of 3
- 21 CFR 606.160Records3 of 3
- 21 CFR 606.60Equipment2 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.194Laboratory records1 of 3
- 21 CFR 640.25General requirements1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2470872 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2470872. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.