Skip to content

NYU Langone Health, Transplantation & Cellular Therapy

610 2nd Ave, New York, New York, United States

FEI 2470026

FDA has 9 inspections on file for NYU Langone Health, Transplantation & Cellular Therapy in New York, New York (FEI 2470026), from 2008 to 2025. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

No warning letter, court action or import refusal is filed under this FEI.

Seven regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
9, 2008–2025
0 OAI · 7 VAI · 2 NAI
Inspections with 483 observations shown
8 of 9
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Oct 30, 2024
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establishment of spec., standards, and test procedures

      Failure to establish scientifically sound and appropriate specifications, standards and test procedures to assure that blood and blood components are safe, pure, potent and effective.

    2. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the processing, storage and distribution of blood and blood components for allogeneic transfusion were not always established, maintained and followed.

  3. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the storage and distribution of blood and blood components for allogeneic transfusion were not always established, maintained and followed.

    2. Required records

      Failure to maintain storage and distribution, quality control and general records.

  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Required records

      Failure to maintain quality control and general records.

    2. Methods for pre-transfusion testing

      The standard operating procedure fails to include a written description of pretransfusion testing, where pretransfusion testing is applicable, including precautions to be taken to identify accurately the recipient blood samples and crossmatched donor units.

    3. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the storage and distribution of each unit of blood and blood components so that all steps can be clearly traced.

    4. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the processing of blood and blood components for allogeneic transfusion were not always established, maintained and followed.

  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the storage and distribution of each unit of blood and blood components so that all steps can be clearly traced.

    2. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the processing, compatibility testing, storage, and distribution of blood and blood components for homologous transfusion and autologous transfusion are not always maintained and followed.

    3. Required records

      Failure to maintain quality control and general records.

    4. Calibration/Inspection/Checking not done

      Routine calibration, inspection, and checking of automatic equipment is not performed according to a written program designed to assure proper performance.

    5. Person performing, test results, interpretation

      Records fail to be as detailed as necessary so as to provide a complete history of the work performed.

    Show 2 more citations
    1. Biological product deviation report

      Failure to submit a biological product deviation report.

    2. Legibility and indelibility

      Records are illegible and not indelible.

  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Records not made readily available to FDA

      Records associated with drug product production, control, and distribution and within the retention period for such records, were not made readily available for authorized inspection.

    2. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the distribution of blood and blood components for homologous transfusion and autologous transfusion are not always maintained and followed.

    3. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.

    4. Biological product deviation report

      Failure to submit a biological product deviation report.

    5. Adequate identification and handling of test samples

      Failure to adequately provide for identification and handling of all test samples so that they are accurately related to the specific recipient.

    Show 2 more citations
    1. Calibration/Inspection/Checking not done

      Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the processing, storage, and distribution of each unit of blood and blood components so that all steps can be clearly traced.

  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. When to report

      Biological product deviations were not reported within the 45 calendar day timeframe.

    2. Documentation

      Process validation activities and results have not been documented and approved.

    3. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the processing and distribution of blood and blood components for homologous transfusion are not always followed.

  8. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Donor suitability procedures not followed

      Failure to follow standard procedures and methods for determining the suitability of a donor as a source of blood.

    2. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    3. Documentation - specific items

      Documentation of process validation activities and results does not include the date and signature of the individuals approving the validation.

  9. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Donor suitability procedures not followed

      Failure to follow standard procedures and methods for determining the suitability of a donor as a source of blood.

    2. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection of blood and blood components for homologous transfusion and further manufacturing purposes are not always followed.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Oct 30, 2024. It asked for a Form 483.

  • Inspection ending Sep 26, 2024VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Oct 30, 2024FDA-FOIA-2024-9624Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 8 of this facility’s 9 inspections, with how many of them cited each.

Show all 11

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2470026 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2470026. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.