FDA has 11 inspections on file for Ferndale Laboratories, Inc. in Ferndale, Michigan (FEI 1811212), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two FOIA requests have asked FDA for this inspection's 483.

The most recent OAI inspection ended on Aug 18, 2010. No warning letter, court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.192, 21 CFR 211.22(d) and 21 CFR 211.25(a).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Ferndale Laboratories, Inc. (D-U-N-S 005320536).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
11, 2009–2026
2 OAI · 7 VAI · 2 NAI
Inspections with 483 observations shown
5 of 11
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest May 11, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not written.

    3. Authority lacking to review records, investigate errors

      The quality control unit lacks authority to fully investigate errors that have occurred.

  3. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Reactive/Additive/Absorptive Containers/Closures

      Drug product containers or closures are reactive and additive so as to alter the safety, identity, strength, quality, and purity of the drug beyond the official or established requirements.

    2. Representative Samples

      Representative samples are not taken of each shipment of each lot of components for testing or examination.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug product containers and drug products conform to appropriate standards of identity, strength, quality and purity.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    5. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function.

    Show 2 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Complaint Record required information

      Complaint records are deficient in that they do not include the known reply to complainant.

    2. Failure to report non-alert ADEs

      Individual ADEs which were not reported to FDA in a post marketing 15-day alert have not been included in a periodic safety report.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function.

    4. Complaint Investigation/Follow-Up Findings

      Complaint records are deficient in that they do not include the findings of the investigation and follow-up.

    5. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

    Show 1 more citation
    1. Failure to develop written procedures

      Written procedures have not been developed for the surveillance of post marketing adverse drug experiences.

  11. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on May 11, 2026. Each one asked for a Form 483.

  • Inspection ending Feb 27, 2026VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 22, 2026. FDAgent holds no copy that FDA posted.

    1. May 11, 2026FDA-FOIA-2026-4821Form 483· 1 of 5 sitesWithdrawn
    2. Apr 14, 2026FDA-FOIA-2026-3721Form 483· 1 of 4 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 11 inspections, with how many of them cited each.

Show all 11

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Ferndale Laboratories, Inc.D-U-N-S 005320536

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1811212 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1811212. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.