Skip to content

Valley View Hospital Blood Bank

1906 Blake Ave, Glenwood Springs, Colorado, United States

FEI 1770142

FDA has 3 inspections on file for Valley View Hospital Blood Bank in Glenwood Springs, Colorado (FEI 1770142), from 2010 to 2016. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 4 citations from this inspection, all under 21 CFR Part 606, the manufacturing rules for blood and blood components. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2010–2016
0 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Person performing, test results, interpretation

      Records fail to include dates of the various entries and be as detailed as necessary so as to provide a complete history of the work performed.

    2. Following manufacturer's instructions

      Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.

    3. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection of blood and blood components for were not always maintained and followed.

    4. Equipment observed, standardized, calibrated

      Equipment used in the collection of blood and blood components is not standardized and calibrated on a regularly scheduled basis as prescribed in the SOP Manual.

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Notification

      Failure to make reasonable attempts to notify the autologous donor's referring physician within 8 weeks after determining that the autologous donor is deferred.

    2. Testing - inspection

      Failure to visually inspect blood during storage and immediately prior to issue for abnormal color, physical appearance, or indication or suspicion of microbial contamination.

    3. Labeling of blood products unsuitable for transfusion

      Failure to prominently label blood and blood components (except for recovered plasma) determined to be unsuitable for transfusion with "NOT FOR TRANSFUSION" and the reason the unit is considered unsuitable.

    4. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.

    5. Donor deferral record - each location

      A record is not available from which unsuitable (deferred) donors may be identified so that products from such individuals will not be distributed.

    Show 2 more citations
    1. Arm preparation

      The phlebotomy site is not prepared by a method that gives maximum assurance of a sterile container of Whole Blood.

    2. Notification w/in 8 weeks

      Failure to make reasonable attempts to notify the donor within 8 weeks after determining that the donor is deferred or determined not to be suitable for donation.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 9

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1770142 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1770142. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.