Reese Pharmaceutical Company
10617 Frank Ave, Cleveland, Ohio, United States
FEI 1518939DUNS 004172052
FDA has 5 inspections on file for Reese Pharmaceutical Company in Cleveland, Ohio (FEI 1518939), from 2009 to 2025. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
One of the two FOIA requests for this site has asked FDA for this inspection's records.
The most recent OAI inspection ended on Nov 24, 2010. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.100(b), 21 CFR 211.125(a) and 21 CFR 211.186(b)(9).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for relabeling and repacking, through Dec 31, 2027. Its registrant is REESE CONSUMER HEALTH CORPORATION (D-U-N-S 004172052).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2009–2025
- 1 OAI · 2 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Nov 17, 2025
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Inspection of packaging and labeling area
Batch production and control records do not include results of the inspection of the packaging and labeling area after use for each batch of drug product produced.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
Distribution Record Requirements
Distribution records do not contain the lot or control number of drug product.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions and specifications.
Show 11 more citations
Lot or control number assigned
The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.
Unlabeled filled containers controls
Filled drug product containers which are set aside and held in an unlabeled condition are not identified to preclude mislabeling of individual containers, lots or portions of lots.
Status of Each Lot Identified
Each lot of drug product containers and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Correct labels during finishing operations
Packaged and labeled products are not examined during finishing operations to provide assurance that containers and packages in the lot have the correct label.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Labeling: documentation of exam and review
There is no documentation of the examination and review of labels and labeling for conformity with established specifications.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Nov 17, 2025.
Inspection ending Sep 25, 2025NAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Nov 17, 2025FDA-FOIA-2025-13016EIRWithdrawn
Inspection date not given
1 request. FDA released records in answer to a request for its EIR on Oct 29, 2025. FDAgent holds no copy that FDA posted.
- Jul 14, 2025FDA-FOIA-2025-8648EIRRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations3 of 3
- 21 CFR 211.125Labeling issuance3 of 3
- 21 CFR 211.186Master production and control records2 of 3
- 21 CFR 211.188Batch production and control records2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.115Reprocessing1 of 3
- 21 CFR 211.130Packaging and labeling operations1 of 3
Show all 14
- 21 CFR 211.134Drug product inspection1 of 3
- 21 CFR 211.170Reserve samples1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.196Distribution records1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1518939, one row per refused product line.
1 refusal on 2024-08-30 · charged NOT LISTED on 1, FRNMFGREG on 1 · no FDA sample analysis
FDA firm profile- 2024-08-30
PYRANTEL PAMOATE (ANTHELMINTIC)60WAA31
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast ImportsSCS-5085103-3/21/1
FDA drug establishment registration
FDA registration search- Registered operations
- Relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- REESE CONSUMER HEALTH CORPORATIOND-U-N-S 004172052
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1518939 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1518939. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.