Skip to content

Rhode Island Blood Center, A Division of New York Blood Center, Inc.

405 Promenade St, Providence, Rhode Island, United States

FEI 1270007

FDA has 8 inspections on file for Rhode Island Blood Center, A Division of New York Blood Center, Inc. in Providence, Rhode Island (FEI 1270007), from 2011 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 3 citations from this inspection, all under 21 CFR Part 606, the manufacturing rules for blood and blood components. They are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
8, 2011–2025
0 OAI · 4 VAI · 4 NAI
Inspections with 483 observations shown
5 of 8
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Sep 30, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Person performing, test results, interpretation

      Records fail to identify the person performing the work, include dates of the various entries and be as detailed as necessary so as to provide a complete history of the work performed.

    2. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection, processing and storage of blood and blood components for allogeneic transfusion, autologous transfusion and further manufacturing purposes were not always established, maintained, followed and available to personnel in the areas where procedures were performed.

    3. Safe, sanitary, orderly storage

      Failure to store all supplies and reagents used in the collection of blood and blood components in a safe, sanitary and orderly manner.

  2. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
  3. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  4. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene Therapies1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the collection of each unit of blood and blood components so that all steps can be clearly traced.

  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. When to report

      Biological product deviations were not reported within the 45 calendar day timeframe.

    2. Required records

      Failure to maintain donor and processing records.

    3. Person performing, test results, interpretation

      Records fail to identify the person performing the work and be as detailed as necessary so as to provide a complete history of the work performed.

    4. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection, processing, compatibility testing, storage, and distribution of blood and blood components for homologous transfusion, autologous transfusion, and further manufacturing purposes are not always maintained and followed.

    5. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the collection of each unit of blood and blood components so that all steps can be clearly traced.

  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Donor Deferral

      Failure to defer a donor who tested reactive by a screening test for evidence of infection due to a communicable disease agent from further donations of human blood and blood components.

    2. Required records

      Failure to maintain donor records.

    3. Safe, sanitary, orderly storage

      Failure to store all supplies and reagents used in the processing of blood and blood components in a safe, sanitary and orderly manner.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    5. Personnel capabilities

      Failure to assure that personnel have the necessary training in and a thorough understanding of the operations which they perform.

    Show 4 more citations
    1. Equipment observed, standardized, calibrated

      Equipment used in the collection of blood and blood components is not standardized and calibrated on a regularly scheduled basis as prescribed in the SOP Manual.

    2. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    3. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.

    4. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection of blood and blood components for homologous transfusion are not always maintained.

  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Required records

      Failure to maintain quality control records.

  8. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Sep 30, 2025. It asked for a Form 483.

  • Inspection ending Aug 1, 2025VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on May 8, 2026. FDAgent holds no copy that FDA posted.

    1. Sep 30, 2025FDA-FOIA-2025-11467Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 8 inspections, with how many of them cited each.

Show all 9

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1270007 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1270007. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.