Skip to content

Airgas USA, LLC

88 Niantic Ave, Providence, Rhode Island, United States

FEI 1212403

FDA has 2 inspections on file for Airgas USA, LLC in Providence, Rhode Island (FEI 1212403), from 2012 to 2015. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 211.192.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2012–2015
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Suitability of testing methods verified

      The suitability of all testing methods is not verified under actual conditions of use.

    2. Determination not to conduct investigation of complaint

      The written record did not include the reason an investigation was found not to be necessary when an investigation into unexplained discrepancies was not conducted.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    4. Labeling Control Records and Label Copies

      The batch production and control records are deficient in that they do not include specimen and copy of labeling.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    3. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    5. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    Show 5 more citations
    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Written sanitation procedures lacking

      There is a lack of written procedures assigning responsibility, providing cleaning schedules, and describing in sufficient detail the methods, equipment and materials to be used for sanitation.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    4. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    5. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 11

Other FEIs recorded as Airgas USA, LLC

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

  • Airgas USA, LLCFEI 1119991Chester, Virginia, United States

    Last inspected 2025-12-02NAI

  • Airgas USA, LLCFEI 1110624Hyattsville, Maryland, United States

    Last inspected 2024-09-30VAI

  • Airgas USA, LLCFEI 1619686Houston, Texas, United States

    Last inspected 2024-08-15VAI

  • Airgas USA, LLCFEI 1022911Kingsport, Tennessee, United States

    Last inspected 2024-08-07NAI

  • Airgas USA, LLCFEI 1314605Rochester, New York, United States

    Last inspected 2024-07-31VAI

  • Airgas USA, LLCFEI 1113562Salisbury, Maryland, United States

    Last inspected 2024-04-23NAI

  • Airgas USA, LLCFEI 2220385Bellmawr, New Jersey, United States

    Last inspected 2024-03-13NAI

  • Airgas USA, LLCFEI 1317232Cheektowaga, New York, United States

    Last inspected 2024-02-23VAI

  • Airgas USA, LLCFEI 1942173Saint Louis, Missouri, United States

    Last inspected 2024-02-15NAI

  • Airgas USA, LLCFEI 1216783Salem, New Hampshire, United States

    Last inspected 2024-01-12VAI

Not every site is listed: these are the most recently inspected sites found under this name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1212403 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1212403. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.