Aphena Pharma Solutions - Maryland, LLC
7978 Industrial Park Rd, Easton, Maryland, United States
FEI 1130591DUNS 829739833
Company: Aphena Pharma Solutions Holdings, Inc. · Linked by exact D-U-N-S match (832743756) in FDA registration data
FDA has 6 inspections on file for Aphena Pharma Solutions - Maryland, LLC in Easton, Maryland (FEI 1130591), from 2011 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the five FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2027. Its registrant, Aphena Pharma Solutions Holdings, Inc. (D-U-N-S 832743756), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2011–2026
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 5 requests, latest May 11, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, testing, approval and rejection of components and drug product containers.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Printing devices
Printing devices used to imprint labeling upon the drug product unit label and case are not monitored to assure that all imprinting conforms to the print specified in the batch production record.
Valid stability test methods
The written stability program for drug products does not include reliable and specific test methods.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Stability testing records not included
Laboratory records do not include complete records of all stability testing performed.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture of a drug product lack the training required to perform their assigned functions.
Documentation
Corrective and preventive action activities and/or results have not been adequately documented.
Lack of or inadequate procedures
Procedures for corrective and preventive action have not been adequately established.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Five requests to FDA under the Freedom of Information Act named this site, most recently on May 11, 2026. Each one asked for a Form 483.
Inspection ending Feb 20, 2026VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 30, 2026. FDAgent holds no copy that FDA posted.
- May 11, 2026FDA-FOIA-2026-4817Form 483· 1 of 5 sitesWithdrawn
- Apr 16, 2026FDA-FOIA-2026-3856Form 483Records released
- Apr 15, 2026FDA-FOIA-2026-3779Form 483· 1 of 5 sitesRecords released
Inspection ending Dec 15, 2021VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 22, 2025FDA-FOIA-2025-9059Form 483Closed
- Dec 12, 2023FDA-FOIA-2023-11077Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.122Materials examination and usage criteria1 of 3
- 21 CFR 211.166Stability testing1 of 3
- 21 CFR 211.194Laboratory records1 of 3
- 21 CFR 820.100Corrective and preventive action1 of 3
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- Aphena Pharma Solutions Holdings, Inc.D-U-N-S 832743756
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Aphena Pharma Solutions Holdings, Inc. (D-U-N-S 832743756) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Aphena Pharma Solutions - Tennessee, LLCCookeville, Tennessee · FEI 300384947911 inspections11latestJul 25, 2022NAI1 warning letter, Dec 5, 2017
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 1130591 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 1130591. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.