Holston Gases, Inc.
368 Terry Blvd, Louisville, Kentucky, United States
FEI 1030296DUNS 829338115
Company: Holston Gases, Inc. · Linked by exact D-U-N-S match (034697276) in FDA registration data
FDA has one inspection on file for Holston Gases, Inc. in Louisville, Kentucky (FEI 1030296). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant, Holston Gases, Inc. (D-U-N-S 034697276), has registered 5 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2011
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Quarantine - actual practice
Drug products are not quarantined before being released by the quality control unit.
Calibration/Inspection/Checking not done
Routine inspection of mechanical equipment is not performed according to a written program designed to assure proper performance.
Written procedures not followed
Written procedures for the receipt and examination of packaging and labeling materials are not followed.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
In-process and laboratory control results
Batch production and control records do not include laboratory control results for each batch of drug product produced.
Show 4 more citations
Quarantine of Rejected Components et. al.
Rejected drug product containers are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.89Rejected components, drug product containers, and closures1 of 1
- 21 CFR 211.122Materials examination and usage criteria1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.142Warehousing procedures1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
Show all 9
- 21 CFR 211.188Batch production and control records1 of 1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Holston Gases, Inc.D-U-N-S 034697276
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Holston Gases, Inc. (D-U-N-S 034697276) as the registrant for this site and the 5 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Holston Gases, Inc.Knoxville, Tennessee · FEI 30101706461 inspection1latestAug 30, 2018NAINone on file
- Holston Gases, Inc.Johnson City, Tennessee · FEI 3003318278Registered; no FDA inspection on file
- Holston Gases, Inc.Decatur, Alabama · FEI 3010166231Registered; no FDA inspection on file
- HOLSTON GASES, INC.SPARTANBURG, South Carolina · FEI 3012607129Registered; no FDA inspection on file
- HOLSTON GASES, INC.NASHVILLE, Tennessee · FEI 3015465256Registered; no FDA inspection on file
Other FEIs recorded as Holston Gases, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Holston Gases, Inc.FEI 3002522848Lexington, Kentucky, United States
Last inspected 2014-07-31NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 1030296 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 1030296. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.