A. Nelson & Co., Ltd.
5 Endeavour Way, London, United Kingdom
FEI 1000568184DUNS 221471234
FDA has 6 inspections on file for A. Nelson & Co., Ltd. in London, United Kingdom (FEI 1000568184), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 68-19 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is A. Nelson & Co. Limited (D-U-N-S 210212924).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2011–2025
- 2 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 6
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Nov 7, 2025
- Import refusals
- 2 refusals
- Import alerts
- 68-19Red List
- Matched on FDA’s firm name and street address
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate microbial testing and specs
Failure to establish appropriate microbial specifications for homeopathic product, in accordance with accepted standards and consistent with the manufacturing process. Specifically, A. Your firm failed to perform microbial testing on the finished liquid homeopathic products intended [illegible] prior to releasing them to the U.S. market. Additionally, your firm failed to conduct microbial testing on the bulk [illegible] before releasing it for finished product packaging. Bulk [illegible] is [illegible] in-house and used as [illegible] for some of these liquid homeopathic products. Since 2023, your firm has distributed homeopathic liquid products into the U.S. market without adequate microbial testing, including but not limited to: [illegible]. Batch [illegible], Batch [illegible], Batch [illegible], Batch [illegible]. USP General Chapter [illegible] establishes specific microbiological acceptance criteria for non-sterile [illegible] products, requiring a maximum limit of [illegible] CFU/g or CFU/mL for the total aerobic microbial count and [illegible] CFU/g or CFU/mL for the total yeast and mold count. The chapter also mandates the absence of E. coli (in [illegible] or [illegible] mL) and Salmonella species (in [illegible] or [illegible] mL) in these non-sterile preparations. Therefore, your firm's failure to perform microbiological testing prevents verification that your homeopathic products meet appropriate microbiological standards and are free of objectionable microorganisms that could pose a risk to consumer health and safety. B. Your firm failed to perform adequate risk assessments to support your microbial testing program for [illegible] products. During the inspection, we observed that the firm relies on the supplier's Certificate of Analysis (CoA) for microbial test results of each batch of bulk [illegible] received and only conducts microbial testing on these [illegible]. However, no documented rationale was provided to demonstrate that this testing approach provides adequate assurance of microbiological quality. Furthermore, record review revealed that the firm tests only [illegible] batch of finished [illegible] for microbial contamination, rather than testing each individual batch. However, the firm's [illegible] testing does not ensure that batches from each market are included. Our review of Form QR 036, "Production Laboratory Sample Record," covering [illegible] showed that none of the [illegible] samples collected during the sampling were intended for the U.S. market. As a result, the [illegible] packaged for the U.S. market during this period were distributed without any microbiological testing. Since 2023, your firm has distributed [illegible] batches of [illegible] and [illegible] batches of [illegible] to the U.S. market without conducting adequate microbial testing. Examples include Batch [illegible], Batch [illegible], Batch [illegible] and Batch [illegible].
- Observation 2
Inadequate OOS investigations and CAPAs
Written records of investigations into unexplained discrepancies do not always include the conclusion and follow-up. Specifically, Investigations initiated and performed by your Quality Unit in response to laboratory investigation reports (OOS) and Quality Incident Reports (QIR) for drug products, are not always comprehensive to determine all potential root causes. Additionally, Corrective and Preventive Actions (CAPAs) as a result of investigations are not always comprehensive to address root causes or adequately documented to have been performed. For Example, A. The firm's out-of-specification (OOS) investigations for [illegible] system failures consistently lack adequate documentation of definitive conclusions and systematic follow-up actions. For example: - OOS 2025-032 (TAMC failure; ID Microbacterium phyllosphaerae), opened April 22, 2025: Investigation closed with no definitive assignable cause identified. No CAPA was documented as a response. - OOS 2024-099 (TAMC failure: ID Staphylococcus capitis), opened November 19, 2024: Investigation closed with no root cause identified, stating "Most probable root cause is due to sampling error". No CAPA was documented as a response. Investigation did not extend to batches manufactured using [illegible] during that period. - OOS 2024-058 (TAMC failure: ID Pseudomonas oryzihabitans), opened July 31, 2024: Investigation closed as inconclusive with no definitive root cause identified. Firm stated that "this is most likely a sampling error" and cited CAPA 447 as a corrective action, which was referenced in OOS 2024-054 and found to be ineffective. Investigation did not extend to batches manufactured using [illegible] during that period. - OOS 2024-054 (TAMC failure; ID Micrococcus luteus), opened July 25, 2024: Investigation closed as inconclusive with no definitive root cause identified despite mentioning two possible causes. CAPA 447, created in response to [illegible] OOS (OOS 2024-065), was referenced as a corrective action. Investigation did not extend to batches manufactured using [illegible] during that period. - OOS 2023-101 (TAMC failure; ID Staphylococcus warneri and Staphylococcus epidermidis), opened October 18, 2023: Investigation determined "Probable root cause is sample contamination by analyst during sampling." Analysts were reminded of aseptic sampling importance, but no CAPA was created to capture this corrective action. Investigation did not extend to batches manufactured using [illegible] during that period. - OOS 2022-049 (TAMC and Pseudomonas spp. failure) opened July 4, 2022: Investigation concluded "No clear root cause identified" and stated contamination during sampling was possible. The risk of microbial contamination as well as the changing procedures were re-explained to the analysts, but no CAPA was initiated to capture this corrective action. These investigations involving various identified microorganisms were closed without establishing definitive root causes. This demonstrates a pattern of inadequate documentation where failures were frequently attributed to "sampling error" or "contamination during sampling" without implementing comprehensive corrective and preventive actions (CAPAs) to address the recurring issues. B. During the inspection, it was observed that your firm failed to adequately investigate quality incident report QIR-206, which was opened due to an import alert triggered by microbial contamination detected during FDA sampling. The affected product was detained and denied entry into the US market. Per your investigation documented in QIR-219, you failed to extend the evaluation to retained samples collected for the same product despite the microbial failure occurring in this lot during FDA testing. Furthermore, the investigation failed to evaluate other batches that were packaged by [illegible] on the same packaging line within the same time period as the affected batch, even though your Head of Quality confirmed that the packaging line
Shortened here; the PDF has the full text.
Show observations 3 to 5
- Observation 3
Improper disposal of cGMP records
Document control procedures under Quality Unit oversight are inadequate. Specifically, During our walkthrough on September 15, 2025, we observed discarded cGMP records in your outside trash bins, QC laboratory waste bins, and QA office shred bins which appear to be cGMP-controlled records. Your document control procedures do not detail record discard and/or shredding operations and which records are permitted to be discarded. The firm's current document control procedures fail to establish adequate protocols for the proper disposal of cGMP records, including criteria for determining which records may be discarded and appropriate disposal methods for different types of controlled records. Examples of these improperly discarded records observed during our walkthrough are listed below. A. Records found in outside trash bins are as follows: - Finished Product Specification (FPS) form for batch printed in error and discarded without proper documentation. - Master Manufacturing Record for [illegible] ml [illegible] campaign, signed by QA but listing incorrect product (should have been [illegible] ml), discarded without proper documentation. - Refractive index test form, printed in error and discarded without proper documentation. - Finished Product Specification (FPS) forms for [illegible] duplicate copies discarded without proper documentation. - Finished Product Specification (FPS) form for batch number [illegible] duplicate copy discarded without proper documentation. - FTIR analysis form for [illegible] batch [illegible] duplicate copy with handwritten batch number [illegible] signed and dated by QA, discarded without proper documentation or authorization. B. Records found in QC Laboratory Waste Bin are as follows: - Completed reagent preparation form dated 09/10/25 with unacceptable pH results, discarded without proper documentation (no laboratory incident report filed) when reagent was re-prepared on 09/11/25. - Handwritten sticky note questioning significant difference between firm's test results ([illegible] 2%) and manufacturer's COA ([illegible] %) for [illegible] against specification of [illegible], with response "No, we have enough work". No OOT investigation was initiated. - Handwritten note containing results dated 04/09/2024, resulting in non-contemporaneous recording of data. - Handwritten note containing test results for [illegible] batch [illegible] dated 04/18/2024, resulting in non-contemporaneous recording of data. - Incomplete identification test form for raw material during training (not completed due to unavailable reagent), discarded without proper documentation. C. Records found in QA Shred Bin are as follows: - Duplicate manufacturing batch record page for line clearance and batch set up checks for [illegible] batch [illegible] discarded without proper documentation. - Blank and incomplete Finished Product Specification Forms printed in duplicate for four batches, discarded without proper documentation. - Various finished product stability test forms (density, [illegible], TLC, identification) issued 08/21/2025 but not used, discarded without proper documentation or explanation when replacement forms were issued 08/26/2025 and executed.
- Observation 4
Insufficient production/process control procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A. During our inspection, we observed that your firm has on numerous occasions extended product shelf life without supporting stability data. For example, your firm extended the shelf life for homeopathic drug product [illegible] batch number [illegible] originally expiring [illegible]. This batch was manufactured around August 2024 and shipped to the US market. Due to excess unsold inventory at the distributor, your firm initiated Planned Process Deviation (PPD) [illegible] dated [illegible] to extend the shelf life from [illegible] to [illegible]. Your firm completed relabeling with a new batch number [illegible] and new expiration date of [illegible] with the repackaged batch awaiting QA review at the time of our inspection. We observed similar shelf-life extension practices during our review of QIR-177, dated [illegible] for batch number [illegible] and QIR-229, dated [illegible] for batch number [illegible]. B. Your firm packages a variety of homeopathic drug products after receiving bulk product from contract manufacturers. While your firm performed a risk assessment dated May 12, 2025, to identify potential risks associated with qualification, packaging processes, and their impact on product quality, patient safety, and regulatory compliance, your firm has not performed process validation studies for these packaging operations as of the current inspection. Process validation studies are necessary to demonstrate that the packaging operations consistently produce products meeting predetermined specifications and quality attributes. Your firm's own risk assessment identified multiple potential issues during packaging operations that require validation, including incorrect packaging components such as [illegible] or labels, incorrect weight of [illegible] within containers, seal integrity for lids, cross contamination from packaging materials, environment, or handling, errors in line clearance procedures leading to product mix-ups, incorrect, missing, or misprinted labeling, packaging integrity and defects, equipment malfunctions, and inadequate equipment cleaning and maintenance. During the current inspection, multiple deviations were observed involving incorrect labeling and expiration dating on packaging labels, demonstrating that the packaging process is not adequately controlled. C. During our walkthrough on September 15, 2025, we observed finished product in unsecured waste bins awaiting pickup by your city waste service provider. Specifically, Lot [illegible] EXP [illegible] along with product cartons were found in this unsecured waste bin. While your firm maintains a second locked waste bin designated for discarded finished products, this secured bin was observed to be at maximum capacity at the time of our inspection. Additionally, your firm does not maintain adequate written procedures for disposal of finished products.
- Observation 5
Inadequate complaint investigations
Complaint investigations under Quality Unit oversight are inadequate. Specifically, A. Your firm failed to conduct adequate investigations for complaints involving the same product and similar adverse events. Three complaints were received for [illegible] reporting similar burning sensations: - CCPF-41394, dated 08/26/2024, for [illegible] batch number [illegible] with a complaint that "[illegible] felt like burning sensation." - CCPF-41415, dated 10/04/2024, for [illegible] batch number [illegible] with a complaint that the product "made burn." - CCPF-41432, dated 11/01/2024, for [illegible] batch [illegible] with a complaint that the product "burned me." Despite having batch numbers available for two of the complaints, the firm did not perform any testing on retained samples. The firm's conclusion that there was "no trend for this issue" was inaccurate, as all three complaints involved the same product and similar burning sensations in the [illegible] area, with the pattern established since the first complaint on 08/26/2024.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Samples (various types) representative, identified properly
Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components are not representative.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Written records kept in individual logs
Written records of major equipment use are not included in individual equipment logs.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all labeling.
Show 3 more citations
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, drug product containers, closures, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the training required to perform their assigned functions.
Quality Control Review
Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Nov 7, 2025. Each one asked for a Form 483.
Inspection ending Sep 19, 2025OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Nov 7, 2025FDA-FOIA-2025-12659Form 483· 1 of 2 sitesRecords released
- Date not givenFDA-FOIA-2026-4286Form 483Records released
Inspection ending Apr 21, 2017VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Aug 2, 2021FDA-FOIA-2021-4987Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 6 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.182Equipment cleaning and use log1 of 1
- 21 CFR 211.198Complaint files1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000568184, one row per refused product line.
2 refusals from 2025-01-10 to 2025-05-16 · charged NEW VET DR on 1, BSE DRUGS on 1 · FDA sample analysis on 2
FDA firm profile- 2025-05-16
RELAXANT N.E.C.65QPL99
NEW VET DR 501(a)(5), 801(a)(3); ADULTERATION
FDA sample analysis
Division of Southeast Imports8GP-0042703-9/191/1
- 2025-01-10
RELAXANT N.E.C.65QBH99
BSE DRUGS 501(a)(2)(A), 801(a)(1); Adulteration
FDA sample analysis
Division of Southeast Imports8GP-0042703-9/111/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 68-19Red ListDETENTION WITHOUT PHYSICAL EXAMINATION OF UNAPPROVED FINISHED NEW ANIMAL DRUGSImport alert pageAlert on fda.gov
Date published 2025-04-21
- FDA’s entry
- A. Nelson & Co., Ltd. · 5 Endeavour Way, London, UNITED KINGDOM
- FDA’s inspection record for FEI 1000568184
- A. Nelson & Co., Ltd. · 5 Endeavour Way, London, United Kingdom
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
2 products
- 65 Q - - 99Relaxant N.E.C.
- 66 V - - 99Miscellaneous Patent Medicines, Etc.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- A. Nelson & Co. LimitedD-U-N-S 210212924
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000568184 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000568184. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.