HK Kolmar USA LLC
102 Life Science Dr, Scott Township, Pennsylvania, United States
FEI 1000221288DUNS 809172885
FDA has 6 inspections on file for HK Kolmar USA LLC in Scott Township, Pennsylvania (FEI 1000221288), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
3 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2026. Its registrant is HK Kolmar USA, LLC (D-U-N-S 809172885).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2009–2024
- 0 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 4 of 6
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- 3 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies.
Equipment for Environmental Control
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Records not made readily available to FDA
Records associated with drug product production and within the retention period for such records, were not made readily available for authorized inspection.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Show 1 more citation
Containers sampled so as to prevent contamination
Containers are not opened, sampled, and resealed in a manner designed to prevent contamination of their contents.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations made into any unexplained discrepancy
Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Label reconciliation discrepancies evaluation/investigation
Discrepancies found outside preset limits when reconciling the quantities of labeling issued, used and returned, were not investigated.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.125Labeling issuance1 of 4
- 21 CFR 211.142Warehousing procedures1 of 4
- 21 CFR 211.180General requirements1 of 4
Show all 10
- 21 CFR 211.188Batch production and control records1 of 4
- 21 CFR 211.192Production record review1 of 4
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000221288, one row per refused product line.
3 refusals on 2017-08-01 · charged NOT LISTED on 3 · no FDA sample analysis
FDA firm profile- 2017-08-01
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBU99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports554-7536222-8/581/1
- 2017-08-01
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBU99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports554-7536222-8/541/1
- 2017-08-01
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PBU99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports554-7536222-8/511/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling
- Registration runs through
- Dec 31, 2026
- Registrant
- HK Kolmar USA, LLCD-U-N-S 809172885
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000221288 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000221288. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.