FDA has one inspection on file for Benchmark Medical, Inc. in Salt Lake City, Utah (FEI 1000117200). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 15 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2012
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Returned drug procedures in writing and followed
Procedures describing the holding, testing, and reprocessing of returned drug products are not in writing.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Plumbing System Defects
The plumbing system contains defects that could contribute to the contamination of drug products.
Written Procedures Not Followed
Written procedures are not followed for the storage and testing of components.
Reader/Photocopy equipment not made available
Suitable reader or photocopying equipment was not made readily available for drug product records maintained using reduction techniques.
Show 10 more citations
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not retained.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not written.
Unlabeled filled containers controls
Filled drug product containers which are set aside and held in an unlabeled condition are not identified and handled to preclude mislabeling of individual containers, lots or portions of lots.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.48Plumbing1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.130Packaging and labeling operations1 of 1
- 21 CFR 211.166Stability testing1 of 1
Show all 14
- 21 CFR 211.170Reserve samples1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.182Equipment cleaning and use log1 of 1
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.204Returned drug products1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000117200 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000117200. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.