KM Pharmaceutical Co. Ltd. warning letter, August 3, 2023
FDA's Center for Drug Evaluation and Research | CDER issued this warning letter to KM Pharmaceutical Co. Ltd. of Pyeongtaek-si, Gyeonggi-do on August 3, 2023 and posted it on August 8, 2023. FDA lists its subject as Refusal to Provide Access to and Copying of Records.
Source: FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Read the full letter on fda.gov. FDAgent is independent of FDA.
- Issued
- Aug 3, 2023
- By CDER
- Posted by FDA
- Aug 8, 2023
- 5 days after issue
- Subject
- Refusal to Provide Access to and Copying of Records
- As FDA lists it
- FDA reference
- MARCS-CMS 663522
- FDA's case number
Violations FDA states in this letter
This letter states no violation sentence that cites a 21 CFR section FDAgent can quote. The full letter is below.
The facility
FDA's compliance action record for this letter (case 663522) names one facility. Each facility's FDA record on FDAgent has its full inspection history.
Inspections
- 2019-02-22VAI5 Form 483 citations
What FDA cited at the February 22, 2019 inspection
- 21 CFR 211.180(e)(2)Items to cover on annual reviews
- 21 CFR 211.160(a)Following/documenting laboratory controls
- 21 CFR 211.28(a)Protective Apparel Not Worn
- 21 CFR 211.188(b)(8)Labeling control records including specimens or copies
- 21 CFR 211.188(b)(4)Weights and measures of components used
The letter
FDA's text of the letter as posted on fda.gov. FDAgent leaves out the address block, the greeting and the copy list, which name the people it was sent to.
Your firm is registered with the United States Food and Drug Administration (FDA or Agency) as a manufacturer of over-the-counter (OTC) drug products, including (b)(4) and hand sanitizer. Ingredients of the drugs registered as manufactured at your firm include ingredients susceptible to Diethylene Glycol (DEG) and Ethylene Glycol (EG) substitution. A review of import records showed multiple shipments of drug products into the United States, which declared KM Pharmaceutical Co. Ltd. as the drug manufacturer. On March 3, 2023, the FDA sent an electronic request for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 374(a)(4), to the contact e-mail address provided in your registration file. This request ultimately went unanswered. A second request was sent via e-mail on March 16, 2023, followed by an attempted contact by telephone with your registered U.S. Agent on April 12, 2023, regarding this matter. The Agency sent a follow-up written request for such records and other information on April 17, 2023. Delivery to you was confirmed by the shipper, but you failed to respond to these attempted communications or otherwise provide the requested records or other information. Pursuant to section 704(a)(4), FDA’s request and follow-up communication included a sufficient and clear description of the records sought.
It is a prohibited act under section 301(e) of the FD&C Act (21 U.S.C. 331(e)) to refuse to permit access to or copying of any record as required by section 704(a).
The use of ingredients contaminated with DEG or EG has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and Other High-Risk Drug Components for Diethylene Glycol and Ethylene Glycol to help you meet the current good manufacturing practice (CGMP) requirements when manufacturing drugs containing ingredients at high-risk for DEG or EG contamination at https://www.fda.gov/media/167974/download.
Because your firm failed to respond to the section 704(a)(4) records requests and associated communication attempts, we have no indication of the level of quality assurance for drugs registered as manufactured at your facility.
Until FDA is able to confirm compliance with CGMP and other applicable requirements, we may withhold approval of any new applications or supplements listing your firm as a drug manufacturer. In addition, shipments of articles manufactured at KM Pharmaceutical Co. Ltd., 121 Pyeongtaekhang-ro, 268 beon-gil, Poseung-eup, Pyeongtaek Gyeonggi, 17953 South Korea, into the United States that appear to be adulterated or misbranded are subject to being detained or refused admission pursuant to section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3).
FDA placed all drugs and drug products manufactured by your firm on Import Alert 66-79 on June 7, 2023.
After you receive this letter, respond to this office in writing within 15 working days. In response to this letter, you may provide information for our consideration as we continue to assess your activities and practices, and/or submit a request to schedule an FDA inspection.
Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI #3010164172 and ATTN: Matthew R. Dionne, Pharm.D., Compliance Officer.
Francis Godwin Director Office of Manufacturing Quality Office of Compliance Center for Drug Evaluation and Research, FDA
Registered U.S. Agent: J.S. Chem International Co. Ahn3060@naver.com
Ask FDAgent about this warning letter
FDAgent reads the letter, the facility's inspections and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The letter, its text, dates, issuing office and subject come from FDA's warning letter pages.
- FDAgent leaves out the letter's address block, greeting and copy list, which name the people it was sent to, and quotes each numbered violation sentence that cites 21 CFR.
- Facilities come from FDA's compliance action record for the letter's case number, or the one FEI the letter names; inspections and citations come from FDA's Data Dashboard.
- FDAgent is independent of FDA.