Skip to content

RXQ Compounding LLC Form 483, September 2015

FDA issued this Form 483 to RXQ Compounding LLC in Albany, Ohio (FEI 3011509553) at the end of a drug inspection that ended September 21, 2015. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 21, 2015
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,040 days after the inspection
Facility
FEI 3011509553
Albany, Ohio

FDA's 9 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Description of containers and closures

    Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.

  2. Sterility/pyrogens - test methods written, followed

    Test procedures relative to appropriate laboratory testing for sterility are not followed.

  3. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.

  4. Labeling Control Records and Label Copies

    The batch production and control records are deficient in that they do not include copy of labeling.

  5. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

  6. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  7. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

  8. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  9. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterMay 19, 2016CDER · 241 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3011509553, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.