Rohto-Mentholatum (Vietnam) Co., Ltd. Form 483, April 2026
FDA issued this Form 483 to Rohto-Mentholatum (Vietnam) Co., Ltd. in Ho Chi Minh, Vietnam (FEI 3008808745) at the end of a drug inspection that ended April 14, 2026. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on October 14, 2026.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 14, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 17, 2026
- 217 days after the inspection
FDA's 8 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that ceilings are not smooth and/or hard surfaces that are easily cleanable.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterOct 14, 2026Rohto Pharmaceutical Co., Ltd. warning letter, October 14, 2026CDER · 183 days after this inspection ended
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.