Professional Partners Inc./ Westcliff Compounding Pharmacy Form 483, May 2016
FDA issued this Form 483 to Professional Partners Inc./ Westcliff Compounding Pharmacy in Newport Beach, California (FEI 3012266548) at the end of a drug inspection that ended May 9, 2016. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 9, 2016
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 17, 2024
- 2,809 days after the inspection
FDA's 8 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Calibration - at intervals, written program, remedial action
The calibration of instruments , apparatus and recording devices is not done at suitable intervals in accordance with an established written program.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.