Skip to content

MSD International GmbH Form 483, April 2025

FDA issued this Form 483 to MSD International GmbH in Co. Cork, Ireland (FEI 3002808087) at the end of a biologics inspection that ended April 11, 2025. It lists 1 observation. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 11, 2025
Biologics · Vaccines and Allergenic Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
563 days after the inspection
Facility
FEI 3002808087
Co. Cork, Ireland

The 1 observation on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate validation of manufacturing system

    You did not adequately validate your (b) (4) (b) (4) to support your V116 (Capvaxive) monovalent bulk conjugate (MBC) drug substance manufacturing operations. Since validating and implementing your (b) (4) utilized for documenting V116 serotype production, quality review, and release on 07DEC2023, multiple deviations have been initiated pertaining to (b) (4) design limitations resulting in potential impact to product quality. For example: a) Deviation QN201223715 was initiated on 18OCT2024 for the following (not all inclusive): • MBC time out of (b) (4) C stored at 2-8°C controlled storage (TOC) calculated but not verified within the (b) (4) to be within the allowed limit ((b) (4)). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without MBC (b) (4) C stored at 2-8°C TOC verification. • MBC time out of 2-8°C TOC not calculated nor verified within the (b) (4) to be within the allowed limit ((b) (4)). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without MBC 2-8°C TOC verification. • (b) (4) hold time not calculated and verified within the (b) (4) to be within the allowed Hold Time limit (b) (4). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without (b) (4) hold time verification. • No tolerance check and verification within the (b) (4) for weight ((b) (4)) of NaCl buffer charged to (b) (4). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without weight of NaCl buffer tolerance check and verification. b) Deviation QN2012278663 was initiated on (b) (4) for the following: • The (b) (4) did not detect that number of (b) (4) passes ((b) (4) passes) was outside the allowable operating parameter range of (b) (4) passes to (b) (4) passes (as defined within U.S. license 0002) for V116 Serotype 23A (Batch Number (b) (4)). This deviation was observed during quality review, assessed for product impact, and released with the batch placed on stability. In response to the deviations listed above, six CAPAs were opened to assess and remediate (b) (4) design errors that were not identified during (b) (4) validation. The status for the six CAPAs are as follows: • CAPA QN201232350 – Complete, waiting for effectiveness verification • CAPA QN201232351 – Open (Due Date: 27APR2025) • CAPA QN201232353 – Complete, waiting for effectiveness verification • CAPA QN201232354 – Complete, waiting for effectiveness verification • CAPA QN201216353 – Complete, waiting for effectiveness verification • CAPA QN201239889 – Complete, waiting for effectiveness verification

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.