MSD International GmbH
Brinny, Innishannon, Co. Cork, Ireland
FEI 3002808087DUNS 985655572
FDA has 6 inspections on file for MSD International GmbH in Co. Cork, Ireland (FEI 3002808087), from 2010 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant is Merck & Co., Inc. (D-U-N-S 054554290).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2010–2025
- 0 OAI · 3 VAI · 3 NAI
- Inspections with 483 observations shown
- 1 of 6
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest May 12, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsPosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate validation of manufacturing system
You did not adequately validate your (b) (4) (b) (4) to support your V116 (Capvaxive) monovalent bulk conjugate (MBC) drug substance manufacturing operations. Since validating and implementing your (b) (4) utilized for documenting V116 serotype production, quality review, and release on 07DEC2023, multiple deviations have been initiated pertaining to (b) (4) design limitations resulting in potential impact to product quality. For example: a) Deviation QN201223715 was initiated on 18OCT2024 for the following (not all inclusive): • MBC time out of (b) (4) C stored at 2-8°C controlled storage (TOC) calculated but not verified within the (b) (4) to be within the allowed limit ((b) (4)). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without MBC (b) (4) C stored at 2-8°C TOC verification. • MBC time out of 2-8°C TOC not calculated nor verified within the (b) (4) to be within the allowed limit ((b) (4)). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without MBC 2-8°C TOC verification. • (b) (4) hold time not calculated and verified within the (b) (4) to be within the allowed Hold Time limit (b) (4). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without (b) (4) hold time verification. • No tolerance check and verification within the (b) (4) for weight ((b) (4)) of NaCl buffer charged to (b) (4). Since (b) (4) implementation, (b) (4) V116 serotype batches were released without weight of NaCl buffer tolerance check and verification. b) Deviation QN2012278663 was initiated on (b) (4) for the following: • The (b) (4) did not detect that number of (b) (4) passes ((b) (4) passes) was outside the allowable operating parameter range of (b) (4) passes to (b) (4) passes (as defined within U.S. license 0002) for V116 Serotype 23A (Batch Number (b) (4)). This deviation was observed during quality review, assessed for product impact, and released with the batch placed on stability. In response to the deviations listed above, six CAPAs were opened to assess and remediate (b) (4) design errors that were not identified during (b) (4) validation. The status for the six CAPAs are as follows: • CAPA QN201232350 – Complete, waiting for effectiveness verification • CAPA QN201232351 – Open (Due Date: 27APR2025) • CAPA QN201232353 – Complete, waiting for effectiveness verification • CAPA QN201232354 – Complete, waiting for effectiveness verification • CAPA QN201216353 – Complete, waiting for effectiveness verification • CAPA QN201239889 – Complete, waiting for effectiveness verification
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on May 12, 2025. It asked for a Form 483.
Inspection ending Apr 11, 2025VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- May 12, 2025FDA-FOIA-2025-4204Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Merck & Co., Inc.D-U-N-S 054554290
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as MSD International GmbH
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
MSD International GmbHFEI 3002807560Clonmel, Ireland
Last inspected 2025-02-17VAI
MSD International GmbHFEI 3017657338Swords, Ireland
Last inspected 2024-11-08VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002808087 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002808087. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.