Skip to content

Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy Form 483, July 2017

FDA issued this Form 483 to Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy in Fort Myers, Florida (FEI 3011123993) at the end of a drug inspection that ended July 20, 2017. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 20, 2017
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
2,372 days after the inspection
Facility
FEI 3011123993
Fort Myers, Florida

FDA's 9 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  2. Establishment of time limitations

    Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

  3. Procedures for non-sterile drug products

    Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written and followed.

  4. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  5. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

  6. Objectionable microbiological contamination

    Each lot of a component, drug product containers and closures liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.

  7. Product flow through building is inadequate

    The flow of though the building is not designed to prevent contamination.

  8. Sterility/pyrogens - test methods written, followed

    Test procedures relative to appropriate laboratory testing for sterility and pyrogens are not written and followed.

  9. Expiration date lacking

    Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3011123993, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.