Skip to content

HHCS Pharmacy, Inc. dba Freedom Pharmacy Form 483, July 2014

FDA issued this Form 483 to HHCS Pharmacy, Inc. dba Freedom Pharmacy in Orlando, Florida (FEI 3004596923) at the end of a drug inspection that ended July 28, 2014. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 28, 2014
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,460 days after the inspection
Facility
FEI 3004596923
Orlando, Florida

FDA's 8 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  2. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  3. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

  4. Aseptic Processing Area

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

  5. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  6. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

  7. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  8. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterMay 14, 2015CDER · 290 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.