Skip to content

Empower Clinic Services LLC dba Empower Pharmacy Form 483, November 2025

FDA issued this Form 483 to Empower Clinic Services LLC dba Empower Pharmacy in Houston, Texas (FEI 3021758709) at the end of a drug inspection that ran from November 3 to November 14, 2025. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on September 18, 2026.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Dec 18, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection
Nov 3–14, 2025
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Dec 18, 2025
34 days after the inspection
Facility
FEI 3021758709
Houston, Texas

FDA's 6 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. FDCA 501(a)(2)(A)

    Inadequate smoke studies

    Smoke studies were inadequately performed under dynamic conditions.

  2. FDCA 501(a)(2)(A)

    Media fills, failure

    Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

  3. FDCA 501(a)(2)(A)

    Personnel, blocked or disrupted first air

    Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.

  4. FDCA 501(a)(2)(A)

    Microbial contamination was present, ISO 5/areas adjacent

    Microbial contamination was present in the ISO 5 area.

  5. FDCA 501(a)(2)(A)

    Failure to clean and disinfect/sterilize equipment, ISO 5 area

    Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.

  6. FDCA 501(a)(2)(A)

    Personnel moving quickly, disrupting unidirectional airflow

    Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3021758709, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.