Skip to content

Empower Clinic Services LCC dba Empower Pharmacy Form 483, December 2023

FDA issued this Form 483 to Empower Clinic Services LCC dba Empower Pharmacy in Houston, Texas (FEI 3021758709) at the end of a drug inspection that ended December 1, 2023. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Feb 12, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Dec 1, 2023
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Feb 12, 2024
73 days after the inspection
Facility
FEI 3021758709
Houston, Texas

FDA's 8 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. FDCA 501(a)(2)(A)

    Use of non-pharmaceutical, ingredients/processing aides

    Use of ingredients not intended for pharmaceutical use in sterile drug production.

  2. FDCA 501(a)(2)(A)

    Biological indicators, not used

    Biological indicators were not used to verify the adequacy of the sterilization cycle.

  3. FDCA 501(a)(2)(A)

    Components/containers/materials, endotoxin contamination

    Compounding with components, containers or other materials that have not been verified to assure that they do not contribute endotoxin contamination that may be objectionable given the product's intended use.

  4. FDCA 501(a)(2)(A)

    Failure to clean and disinfect/sterilize equipment, ISO 5 area

    Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.

  5. FDCA 501(a)(2)(A)

    Failure/inadequate, filter integrity testing

    Inadequate post-use filter-integrity testing on filters used to sterilize drug products.

  6. FDCA 501(a)(2)(A)

    Personnel infrequently, changed/sanitized gloves

    Personnel infrequently changed and sanitized gloves to prevent contamination.

  7. FDCA 501(a)(2)(A)

    Personnel, blocked or disrupted first air

    Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.

  8. FDCA 501(a)(2)(A)

    Lack of/inadequate, environmental monitoring

    Inadequate routine environmental monitoring in the ISO 5 area and classified areas.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3021758709, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.