Empower Clinic Services LCC dba Empower Pharmacy Form 483, December 2023
FDA issued this Form 483 to Empower Clinic Services LCC dba Empower Pharmacy in Houston, Texas (FEI 3021758709) at the end of a drug inspection that ended December 1, 2023. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Feb 12, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Dec 1, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Feb 12, 2024
- 73 days after the inspection
FDA's 8 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical, ingredients/processing aides
Use of ingredients not intended for pharmaceutical use in sterile drug production.
- FDCA 501(a)(2)(A)
Biological indicators, not used
Biological indicators were not used to verify the adequacy of the sterilization cycle.
- FDCA 501(a)(2)(A)
Components/containers/materials, endotoxin contamination
Compounding with components, containers or other materials that have not been verified to assure that they do not contribute endotoxin contamination that may be objectionable given the product's intended use.
- FDCA 501(a)(2)(A)
Failure to clean and disinfect/sterilize equipment, ISO 5 area
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.
- FDCA 501(a)(2)(A)
Failure/inadequate, filter integrity testing
Inadequate post-use filter-integrity testing on filters used to sterilize drug products.
- FDCA 501(a)(2)(A)
Personnel infrequently, changed/sanitized gloves
Personnel infrequently changed and sanitized gloves to prevent contamination.
- FDCA 501(a)(2)(A)
Personnel, blocked or disrupted first air
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
- FDCA 501(a)(2)(A)
Lack of/inadequate, environmental monitoring
Inadequate routine environmental monitoring in the ISO 5 area and classified areas.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3021758709, newest first.
- Form 483, November 2025Inspection ended Nov 14, 2025 · Posted Dec 18, 2025OAI
- Form 483, October 2024Inspection ended Oct 4, 2024 · Posted Feb 7, 2025OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.