Empower Clinic Services LLC dba Empower Pharmacy
7601 N Sam Houston Pkwy W Ste 100, Houston, Texas, United States
FEI 3021758709
FDA has 3 inspections on file for Empower Clinic Services LLC dba Empower Pharmacy in Houston, Texas (FEI 3021758709), from 2023 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 6 citations from this inspection. They are listed below. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: FDCA 501(a)(2)(A).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2023–2025
- 3 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Requested under FOIA
- 7 requests, latest Oct 17, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were inadequately performed under dynamic conditions.
- FDCA 501(a)(2)(A)
Media fills, failure
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
- FDCA 501(a)(2)(A)
Personnel, blocked or disrupted first air
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
- FDCA 501(a)(2)(A)
Microbial contamination was present, ISO 5/areas adjacent
Microbial contamination was present in the ISO 5 area.
- FDCA 501(a)(2)(A)
Failure to clean and disinfect/sterilize equipment, ISO 5 area
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.
Show 1 more citation
- FDCA 501(a)(2)(A)
Personnel moving quickly, disrupting unidirectional airflow
Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Lack of/inadequate, environmental monitoring
Inadequate routine environmental monitoring in the ISO 5 area.
- FDCA 501(a)(2)(A)
Failure to clean and disinfect/sterilize equipment, ISO 5 area
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.
- FDCA 501(a)(2)(A)
Beta-lactam, hazardous, highly potent drugs, prevention of cross-contamination
Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Production areas, difficult to clean/particle generating
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces.
- FDCA 501(a)(2)(A)
Lack of, routine certification of the ISO 5
Lack of routine certification of the ISO 5 area.
Show 3 more citations
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were not and were inadequately performed under dynamic conditions.
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical, ingredients/processing aides
Use of ingredients not intended for pharmaceutical use in non-sterile drug production.
- FDCA 501(a)(2)(A)
Media fills, failure
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical, ingredients/processing aides
Use of ingredients not intended for pharmaceutical use in sterile drug production.
- FDCA 501(a)(2)(A)
Biological indicators, not used
Biological indicators were not used to verify the adequacy of the sterilization cycle.
- FDCA 501(a)(2)(A)
Components/containers/materials, endotoxin contamination
Compounding with components, containers or other materials that have not been verified to assure that they do not contribute endotoxin contamination that may be objectionable given the product's intended use.
- FDCA 501(a)(2)(A)
Failure to clean and disinfect/sterilize equipment, ISO 5 area
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.
- FDCA 501(a)(2)(A)
Failure/inadequate, filter integrity testing
Inadequate post-use filter-integrity testing on filters used to sterilize drug products.
Show 3 more citations
- FDCA 501(a)(2)(A)
Personnel infrequently, changed/sanitized gloves
Personnel infrequently changed and sanitized gloves to prevent contamination.
- FDCA 501(a)(2)(A)
Personnel, blocked or disrupted first air
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
- FDCA 501(a)(2)(A)
Lack of/inadequate, environmental monitoring
Inadequate routine environmental monitoring in the ISO 5 area and classified areas.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Oct 17, 2026.
Inspection ending Nov 14, 2025OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jan 6, 2026FDA-FOIA-2026-170Form 483· 1 of 5 sitesRecords released
- Dec 9, 2025FDA-FOIA-2025-13774Form 483· 1 of 2 sitesDirected Requester to Publically Available Information
Inspection ending Oct 4, 2024OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- May 27, 2025FDA-FOIA-2025-4710Form 483Closed
- Nov 6, 2024FDA-FOIA-2024-9863Form 483· 1 of 3 sitesClosed
Inspection date not given
3 requests.
- Oct 17, 2026FDA-FOIA-2026-10114Form 483· 1 of 5 sitesOpen
- Dec 19, 2025FDA-FOIA-2025-14201EIR· 1 of 2 sitesClosed
- Oct 29, 2025FDA-FOIA-2025-12441Form 483Directed Requester to Publically Available Information
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3021758709 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3021758709. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.