Ultimate F/X Lasers and Pyrotechnics LLC
710 Ridge Dr, Marengo, Illinois, United States
FEI 3021402469
FDA has one inspection on file for Ultimate F/X Lasers and Pyrotechnics LLC in Marengo, Illinois (FEI 3021402469). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 15 citations from this inspection. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2022
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Emission indicator - Class IIIb & IV
An emission indicator was not incorporated in each laser system classified as a Class IIIb or Class IV laser product, which provides a visible or audible signal during emission of accessible laser radiation in excess of the accessible emission limits of Class I.
Quality control procedures
You have not established and maintained records containing a description of quality control procedures with respect to electronic product radiation safety.
Safety interlock not provided
Each laser product was not provided with at least one safety interlock for each portion of the protective housing which is designed to be removed or displaced during operation or maintenance, when such removal or displacement permitted human access to laser or collateral radiation in excess of the accessible emission limits of Class I and table VI.
ID label lacks place, month & year of manufacture
An identification label fails to provide the place, month and year of manufacture.
Remote interlock connector
Each laser system classified as a Class IIIb or Class IV laser product was not incorporated with a readily available remote interlock connector having an electrical potential difference of no greater than 130 root-mean-square volts between terminals.
Show 10 more citations
Failure to submit
You did not submit an annual report by the September 1 deadline for products requiring one.
ID label lacks name and address
An identification label failed to provide the name and address of the manufacturer and individual or company under whose name the product was sold.
Logotype label output information
Each laser product does not have affixed a label bearing the DANGER logotype specified in the regulation.
NIPH label wording - Class IIIb
Labels regarding Class IIIb accessible laser radiation which are visible on the protective housing prior to displacement or removal of such portions of the protective housing and include the wording: "DANGER --- Laser radiation when open. AVOID DIRECT EXPOSURE TO BEAM." were not provided for noninterlocked protective housings.
Aperture label - laser radiation
The warning statement "AVOID EXPOSURE---Laser radiation is emitted from this aperture" was not affixed in close proximity to each aperture through which is emitted accessible laser or collateral radiation in excess of the accessible emission limits of Class I and table VI of Section 1040.10(d).
Received from dealers or distributors
You have not established and maintained records received from dealers or distributors pursuant to 21 CFR 1002.41.
Certification label or tag
A certification label or tag is not permanently affixed or inscribed, legible and readily accessible to view when the product is fully assembled for use.
Controls, maintenance
Adequate instructions for service adjustments and service procedures were not provided or caused to be provided for each laser model, including a listing of those controls and procedures that could be utilized by persons other than the manufacturer or manufacturer's agent to increase accessible emission levels of radiation and a schedule of maintenance necessary to keep the product in compliance.
Class IIIb "Danger" label
Each Class IIIb laser product does not have affixed a label bearing the DANGER logotype specified in the regulation and bearing the wording "LASER RADIATION--AVOID DIRECT EXPOSURE TO BEAM" in the position specified in the regulation.
Key control
Each laser system classified as a Class IIIb or Class IV] laser product did not incorporate a[key-actuated master control
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 1002.13Annual reports1 of 1
- 21 CFR 1002.30Records to be maintained by manufacturers1 of 1
- 21 CFR 1010.2Certification1 of 1
- 21 CFR 1010.3Identification1 of 1
- 21 CFR 1040.10Laser products1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3021402469 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3021402469. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.