One Umbilical Cord Lab, Inc.
2100 N Collins Blvd Ste 310, Richardson, Texas, United States
FEI 3013913163
FDA has one inspection on file for One Umbilical Cord Lab, Inc. in Richardson, Texas (FEI 3013913163). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 14 citations from this inspection: 8 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 6 under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2020
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Establishing a system
A tracking system that enables the tracking of HCT/Ps back and forth from the donor to the consignee or final disposition was not established, maintained and implemented.
Show 9 more citations
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
Infection with communicable disease agents
Donors were not tested for evidence of infection with relevant communicable disease agents.
Testing, screening, donor eligibility procedures
You did not establish and maintain procedures for determining the eligibility of HCT/P donors.
Kits not FDA approved, specifically labeled
Communicable disease agent tests were not FDA-licensed, approved or cleared donor screening tests.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval and rejection of components, drug product containers and closures.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic process.
Ten year retention
Records pertaining to HCT/Ps were not retained at least 10 years after the date of distribution, disposition, or expiration, whichever was latest when the date of administration of the HCT/P was unknown.
Determination based on screening and testing
HCT/P donors were not determined to be eligible based on the results of donor screening and testing.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 1271.47What procedures must I establish and maintain?1 of 1
Show all 13
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 1
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?1 of 1
- 21 CFR 1271.80What are the general requirements for donor testing?1 of 1
- 21 CFR 1271.85What donor testing is required for different types of cells and tissues?1 of 1
- 21 CFR 1271.290Tracking1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013913163 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013913163. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.