Orbbo Biotechnology LLC
600 Wilshire Blvd Ste 640, Los Angeles, California, United States
FEI 3013306147
FDA has one inspection on file for Orbbo Biotechnology LLC in Los Angeles, California (FEI 3013306147). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 8 citations from this inspection, all under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Documentation elements for activities
Documentation for activities related to the receipt, shipment and distribution of HCT/Ps did not include identification of the HCT/P and the establishment that supplied the HCT/P and date(s) of activity.
Procedures re complaints
Procedures for the review, evaluation, documentation and investigation of complaints relating to core CGTP requirements were not established and maintained.
Acceptance criteria designed to prevent CD
Incoming HCT/Ps were not accepted based on pre-established criteria designed to prevent communicable disease transmission.
Periodic review of temperatures
Recorded storage temperatures were not periodically reviewed to ensure that temperatures have been within acceptable limits.
All core requirements covered in program
A quality program which addresses all of the core CGTP requirements, appropriate for the HCT/Ps manufactured and the manufacturing steps performed, has not been established and maintained.
Show 3 more citations
Calibrated per established schedules
Equipment used for measuring was not calibrated according to established schedules.
Establishing a system
A tracking system that enables the tracking of HCT/Ps back and forth from the donor to the consignee or final disposition was not followed.
Procedures for cleaning, sanitation
Procedures for facility cleaning and sanitation were not established and documented.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 1271.160Establishment and maintenance of a quality program1 of 1
- 21 CFR 1271.190Facilities1 of 1
- 21 CFR 1271.200Equipment1 of 1
- 21 CFR 1271.260Storage1 of 1
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P1 of 1
- 21 CFR 1271.290Tracking1 of 1
- 21 CFR 1271.320Complaint file1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013306147 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013306147. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.