Promise Pharmacy, LLC
31818 Us Highway 19 N, Palm Harbor, Florida, United States
FEI 3013207472
FDA has 2 inspections on file for Promise Pharmacy, LLC in Palm Harbor, Florida (FEI 3013207472), from 2018 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Oct 25, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2018–2021
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Use of non-pharmaceutical components
You used a non-pharmaceutical grade component in the formulation of a drug product. Specifically, your firm routinely uses non-pharmaceutical grade components for compounding drug products. A review of the Certificate of Analysis for various components noted: 1) Non-pharmaceutical grade components were used in processing injectable drug products for example: were used in compounding TRIM Thermal Lot • [(b)(4) . Lot ~(~f(4) I&Lot[(b)(4) #02042021@5 BUD 03/21/2021. • (b)(4) Lot#(b)(4) was used in compounding TRIM Thermal Lot#02042021@5 BUD 03/21/2021. • (b)(4) Lot#(b)(4) was used in compounding TRIM Thermal Lot#02042021@5 BUD 03/21/2021. • (b)(4) Lot[(b)(4) ]was used in compounding TRIM Thermal Lot #02042021@5 BUD 03/21/2021. • [(b)(4) ]Lot[(b)(4) ]was used in compounding TRIM Calm Lot #07282021@1 BUD 11/05/2021. • [(b)(4) ](98%) Lot[(b)(4) ]was used in compounding TRIM Calm Lot #07282021@1 BUD 11/05/2021. • Ipamorelin Acetate Lot ,(~).(1L .., was used in compounding Ipamorelin/Sennorelin PF 15mg/15mg injectable Lot #08192021@4 BUD 03/17/2022. • Sennorelin Acetate Lot#((b)(4)7 was used in compounding Ipamorelin/Sennorelin PF 15mg/15mg injectable Lot #08192021@4 BUD 03/17/2022. • Thymosin B4 Acetate Lot(b)(4)7 was used in compounding Thymosin B4 PF 15mg injectable Lot #08192021@3 BUD 02/15/2022. • Epithalon Acetate Lot[(b)(4) ]was used in compounding Epithalon PF 15mg injectable Lot #08192021@1 BUD 02/15/2022. • Kisspeptin-10 Acetate Lot#(b)(4) was used in compounding Kisspeptin-10 1mg/ml (3ml) injectable Lot #08242021@1 BUD 02/20/2022. • Deoxycholic Acid Lot#(b)(4) was used in compounding Phosphatidylcholine 5% 50mg/ml injectable Lot #08232021@2 BUD 01/20/2022. • Glycyrrhizic Acid Lot( ~).(1) ,was used in compounding Glycyrrhizic Acid PF 8mg/ml injectable Lot #08112021@2 BUD 09/25/2021. • Melanotan II Acetate Lot[(b)(4)] was used in compounding Melanotan II PF 10mg injectable Lot #06242021@1 BUD 12/18/2021. • BPC-157 Acetate Lot#[(b)(4)] was used in compounding BPC-157 PF 10mg Vial injectable Lot #08052021@2 BUD 02/01/2022. • (b)(4) Lot:(b)(4) was used in compounding TRIM Complete Lot#08242021@4 BUD 10/08/2021. 2) Non-pharmaceutical grade components were used in processing non-sterile drug products for example: • Green Tea Powder Extract Lot~(b)(4) was used in compounding Revitalizing Eye Cream Lot #08312021@3 BUD 09/30/2021. • Kisspeptin-10 Acetate Lot#(b)(4) was used in compounding Kisspeptin-10 200mcg Troche Lot #08192021@9 BUD 02/15/2022. • BPC-157 Acetate Lot[(b)(4)] was used in compounding BPC 157 0.5mg Capsule Lot #07142021@10 BUD 01/10/2022. • AOD9604 Acetate Lot:(~).(1L .., was used in compounding AOD 0.5mg Troche Lot #06152021@28 BUD 12/12/2021.
- Observation 2
Gloved hands touched outside surfaces
Personnel were observed touching equipment or other surfaces located outside of the ISO 5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Specifically, On 08/30/2021, I observed a technician touch with their gloved hands a formulation worksheet located outside of the ISO 5 hood and then return to the inside of the ISO 5 hood to continue processing an injectable drug product without sterilizing their gloved hands. The technician was processing the injectable drug product LIPO-C Lot# 08302021@1 BUD 11/28/2021 contained in '(b)(4) vials.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Product flow through building is inadequate
The flow of components, drug product containers, closures and in-process materials though the building is not designed to prevent contamination.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Show 2 more citations
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013207472 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013207472. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.