BayCare Integrated Service Center LLC
Temple Terrace, Florida, United States
FEI 3013023419
FDA has 3 inspections on file for BayCare Integrated Service Center LLC in Temple Terrace, Florida (FEI 3013023419), from 2019 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2019–2026
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetOutsourcing FacilityPosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Environmental monitoring deficiencies
OBSERVATION 1 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Your firm does not routinely conduct dynamic viable air monitoring within the critical ISO 5 classified filling zone of the [(b) (4)] machine cell area throughout filling operations as required by SOP P-204.7 "Quality Management Program for Environmental and Personnel Sampling". The [(b) (4)] procedures requires that for [(Q) (4)] "if a [(H)] is used on one day, it will be monitored under dynamic activity". This lack of viable air monitoring during active manufacturing phases fails to provide real-time assurance of aseptic conditions in a critical processing environment. B. Your ISO 7 Buffer Room, ISO 8 Ante Room, and associated [(D) (4)], which serve as essential [(6) (4)] for materials and personnel supporting ISO 5 aseptic operations, are sampled [(b) (4)] instead of [( )( )] during production. Your procedure P-204.7, "Quality Management Program for Environmental and Personnel Sampling," explicitly states that "all support areas (ISO 7/8 buffer/ante/gowning room) in use will be monitored [(D) (4)]" This [(6) (4)] sampling frequency does not provide adequate assurance of environmental control in these critical support areas. C. Your ISO 5 LAFW environmental and personnel monitoring samples are collected routinely in the [(b) (4)] typically within [(6) (4)] of production [(b) (4)] for batch processing operations that extend for [(b) (4)]. For example, ISO 5 surface sampling and personnel glove sampling are not routinely performed at the conclusion of each shift. In addition, non-viable particle monitoring for (b)(4) is not continuous throughout the entire process. Instead as per SOP P-206.5 "Non-Viable Particle Testing" ISO 5 (locations will sample (b)(4) about (6)(4)72 (6)(4) and all other locations (ISO 7, ISO 8) will be sampled (o)(4) for ( ) (4) (about (6) (4). This inadequate sampling frequency and timing fails to provide scientifically sound assurance that environmental conditions remain consistently acceptable throughout the entire production process. D. On 02/17/26, during the walkthrough, I observed that petri dishes for active air sampling, swab samples, and (b)(4) plates for environmental monitoring are being incubated inside (b)(4). For example, EM plates collected on 2/10/26, 2/11/26 and 2/12/26, observed during the walkthrough, were placed in a (b)(4) for incubation. SOP P-212.7 "Incubation and Inspection of Solid and Liquid Media for Microbial Growth" requires placing samples into (b)(4) and removing excess air or space from the (b)(4) before incubation. This practice creates a low oxygen environment that inhibits optimal aerobic microbial growth and can result in false negative results. Your firm lacks documented growth promotion studies or other scientific evidence demonstrating that this incubation practice does not adversely affect bacterial and fungal growth.
- Observation 2
Inadequate disinfectant validation/rotation
OBSERVATION 2 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Your disinfectant efficacy study is inadequate because it fails to demonstrate sporicidal activity. Your firm relies on (b) (4) with a (b) (4) contact time as its primary sporicidal agent for (b) (4) (b) (4) only). (b) (4) and (b) (4) cleaning activities, as specified in SOP P-305.7 "Cleaning and Disinfection of ISO Classified Controlled Environments and Rooms". However, the validation for this agent, documented in the "Final Report for Disinfection Efficacy Test Study" (Protocol # PRO 22-002), is inadequate for this purpose. The protocol explicitly states that the challenge organisms Bacillus subtilis and Aspergillus brasiliensis were tested only in their vegetative state. The study did not include any testing against their respective highly resistant spores. Therefore, your firm possesses no data to support the claim that your cleaning program is effective at killing bacterial or fungal spores, which is the primary reason for using a sporicidal agent. Manufacturer's data for [(b) (4)] states that a (b) (4) contact time is required to achieve a satisfactory sporicidal kill. Your (b) (4) contact time specified in SOP P-305.7 is scientifically unsupported and demonstrably ineffective for sporicidal action based on the data available for the sporicidal product. Since July 2023, environmental monitoring data consistently shows the recovery of spore-forming bacteria, primarily from the Bacillus and Paenibacillus genera, within the facility. A total of 36 distinct instances of spore-former recovery have been identified from non-water samples between July 2023 and February 2026. These recoveries are split between personnel samples: 20 events (e.g., gloves, cuffs, sleeves, chest) and facility samples: 16 events (e.g., (b) (4) Vestibule, various critical surfaces). Notably, 19 of these 36 events occurred in 2025 alone, indicating a continued and significant presence of these resilient microorganisms. B. Your firm failed to establish a disinfectant rotation program. Your cleaning procedures, including P-305.7, rely exclusively on a single class of chemical (an [(b) (4)] agent, [(b) (4)]) for all scheduled sporicidal cleaning activities ((b) (4)). While (b) (4) is used for residue removal, it is not part of a rotational schedule with a [(b) (4)] chemically distinct agent.
Show observations 3 to 9
- Observation 3
Insufficient visual inspection procedures
OBSERVATION 3 Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A. Your firm's visual inspection program, as outlined in procedure P-614.5 "Visual Inspection of Ingredients and Compounded Sterile Preparations," fails to establish a scientifically sound and documented acceptance sampling plan. The required [(b) (4)] inspection by the Quality Services Unit after a 100% visual inspection is arbitrary and lacks scientific justification. It is not explicitly tied to a statistically sound Acceptable Quality Limit (AQL) plan, such as ANSI/ASQ Z1.4, which is a standard for ensuring the quality of batches. Furthermore, the procedure mentions defect severities (Critical, Major, Minor) but does not provide specific AQL values (e.g., percentage of acceptable defects) for each category. The procedure does not incorporate defined quality inspection criteria for the AQL assessment, including specifications for sample size determination relative to total lot quantity, the designated sampling plan, and acceptance thresholds for defect tolerance. This absence of adequate written procedures for AQL criteria compromises the ability to objectively determine if a batch conforms to appropriate quality standards for release. B. Your visual inspection procedure, P-614.5, lacks adequate written controls for inspection parameters. It does not specify appropriate light intensity requirements (e.g., a [(b) (4)] range) for the "light box" used during inspection, nor does it mandate routine monitoring and calibration of these light sources. C. The procedure, P-614.5, and its associated competency assessment form, F-410.k, fail to establish clear acceptance criteria for defect detection rates or for false rejects during the assessment. Moreover, these procedures do not detail how the qualification process simulates "worst-case" scenarios, such as inspecting a diverse range of product types, container types, and various defect challenges. Additionally, the procedure does not incorporate a requirement for the assessment and qualification of visual inspection personnel under fatigue-induced conditions to evaluate potential impacts on inspection accuracy and defect detection reliability.
- Observation 4
No two-person lab verification
OBSERVATION 4 Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards. Specifically, Your firm does not perform contemporaneous two-person verification of environmental monitoring plates. A single laboratory technician reads environmental plate samples and records the results of the plate counts on a worksheet. There is no assurance that the operator has entered the data accurately.
- Observation 5
Quality unit role conflicts
OBSERVATION 5 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, Your firm's Quality Unit lacks segregation of duties among personnel involved in quality control activities, thereby compromising the independence and integrity of quality oversight. Specifically, your Quality Unit, comprised of a single quality manager and one technician, assumes multifarious roles that include: • Collection of environmental and personnel monitoring samples. • Reading and interpretation of environmental and personnel monitoring sample results. • Initiation and conduct of investigations into deviations, including out-of-specification (OOS) environmental monitoring results. • Review of batch records for compliance. • Final release of finished drug products for distribution. For example, from 11/17/25 to 11/25/25, Quality & Testing Manager collected, incubated, and performed readings of lot related environmental monitoring samples for lot SUCC10020251114. On 11/25/25 the Q&T Manager segregated the lot and provided a partial release of the lot. On 11/26/25, the Q&T Manager initiated a Quality Related Event (QRE) investigation reporting a microbial recovery in one of the samples. On 12/29/26 the Q&T Manager signed final review of the investigation. This consolidation of responsibilities within a limited number of personnel creates a significant potential for conflicts of interest and precludes independent oversight. The same individuals responsible for generating environmental monitoring data, and subsequently investigating any excursions, also hold the authority to release drug products influenced by that data.
- Observation 6
Premature release after microbial finding
OBSERVATION 6 There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, Your firm prematurely released a portion of drug product batch SUCC10020251114 for distribution prior to the initiation and completion of a thorough investigation into a detected microbial recovery, thereby failing to assure that the drug product meets its specifications for quality and purity before release. Specifically: • Environmental monitoring samples collected during the processing of lot SUCC10020251114 detected a microbial recovery (single CFU on a pharmacist's (b)(4) glove cuff) on 11/24/25, as recorded during the final stage of incubation. • On 11/25/25, your Quality & Testing Manager segregated the lot by loader and authorized a partial release of batch SUCC10020251114. The unaffected portion of the lot was deemed appropriate for release, and [(b) (4)] syringes from this portion were consequently released. • However, the Quality Related Event (QRE) investigation (QRE #: 25-018) reporting this critical microbial recovery was not initiated until 11/26/25 - after the partial release of the drug product had already occurred. The lot was distributed on 12/2/25. The identification of the microorganism (Corynebacterium afermentans ss lipophilum) was not returned until 12/11/25, and the final review and approval of this investigation were not signed until 12/29/25 and approved by the Director of Pharmacy on 1/26/26. This practice demonstrates a lack of thorough review of an unexplained discrepancy prior to product distribution, as a significant portion of the batch was released before conclusive evidence regarding the nature, root cause, and potential impact of the microbial recovery was fully established and documented in a completed investigation.
- Observation 7
Deficient IV bag visual inspection
OBSERVATION 7 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, Your firm's visual inspection procedures for products repackaged into intravenous (IV) bags are deficient. Your visual inspection procedures request to perform a 100% visual inspection of IV bags after bags have been labeled. For example, Batch Production Records F-671.ca for Oxytocin and F-671.yb for Fentanyl Ropivacaine Epidural, under the "Visual Inspection (light box)" section, state: "Observe each labelled bag in the light box for no less than [(b) (4)],... Check for product clarity and label for legibility." There is no assurance that the label, once applied to the IV bag, will not obstruct or impede the detection of particulates or other critical defects within the product.
- Observation 8
Surveillance video not retained
OBSERVATION 8 All records of production associated with a batch of drug product were not maintained at least one (1) year after the expiration date. Specifically, Surveillance video is used by your firm for investigation of production discrepancies including but not limited to environmental and personnel monitoring excursions. Video recordings of gowning and production activities are described and referenced in written investigation reports and have been used to establish root cause. However, these video recordings are not maintained by your firm. Examples include but are not limited to the following: • QRE25-018 - "Video review showed [(b) (6)] failed to disinfect the vestibule door handle (a high-touch area) and did not perform SS&D after wiping materials down before loading", • QRE25-017 - "Video review showed [(r(6)itlil?)] failed to perform SS&D consistently and after retrieving supplies", • QRE 25-016 - "Video review showed [(li)(6).(I)] failed to change gloves after cleaning vestibules and did not fully SS&D cuffs", etc.
- Observation 9
No written annual product reviews
OBSERVATION 9 Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected. Specifically, Your firm does not maintain written records for annual product reviews conducted for your aseptically produced drug products, including but not limited to the following information: Trends, reports, or summaries of quality indicators, a summary of all media fills performed since last inspection, environmental monitoring trend data (microbial and particle counts), personnel monitoring trend data, evaluations of investigations and effectiveness of corrective actions, change management, evaluation of unexpected results or trends, Out-of-Specification (OOS) results, product rejects, etc.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 503B(a)(10)(A)
Drug product labels, fails to include
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- FDCA 501(a)(2)(A)
Disinfectant contact time
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Regulations FDA cited here
The 3 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.192Production record review1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013023419 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013023419. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.