Skip to content

Biovem, Inc.

2001 N Federal Hwy Ste 318, Pompano Beach, Florida, United States

FEI 3012119346

FDA has one inspection on file for Biovem, Inc. in Pompano Beach, Florida (FEI 3012119346). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 10 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2016
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Distribution Recall System

      The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.

    2. Written procedures followed

      Procedures for the preparation of master production and control records are not described in a written procedure and followed.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    4. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    5. Written procedures describing in detail

      There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling and examination of labeling and packaging materials.

    Show 5 more citations
    1. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are not written or followed.

    2. Items to cover on annual reviews

      Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.

    3. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced.

    4. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.

    5. Reserve samples identified, representative, stored

      Reserve drug product samples are not appropriately identified, representative of each lot or batch of drug product and retained and stored under conditions consistent with product labeling.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 10

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012119346 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012119346. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.