Skip to content

Outin Futures Corp

154 Gieopdosi 1-Ro, Daesowon-Myeon, Chungju, Korea (the Republic of)

FEI 3011572099DUNS 689851514

FDA has 3 inspections on file for Outin Futures Corp in Chungju, Korea (the Republic of) (FEI 3011572099), from 2017 to 2024. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

1 import refusal is filed under this FEI, on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is OUTIN FUTURES CORP. (D-U-N-S 689851514).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2017–2024
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest May 14, 2026
Import refusals
1 refusal
Import alerts
66-40Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning SOPs/equipment protection

      Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    3. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    4. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    5. Approve or reject components, products

      The quality control unit lacks the responsibility and authority to approve and reject all components, in process materials and drug products.

    Show 4 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. In-process materials characteristics testing

      In-process materials are not tested for and approved or rejected by the quality control unit after storage for long periods.

    3. Review of representative number of batches

      Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    4. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Accelerated stability studies

      Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.

    2. Cleaning/maintenance records not kept

      Records are not kept for the cleaning of equipment.

    3. In-process materials characteristics testing

      In-process materials are not tested for and approved or rejected by the quality control unit after storage for long periods.

    4. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    5. In-process sample representation/identification

      In-process samples are not representative.

    Show 2 more citations
    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Valid stability test methods

      The written stability program for drug products does not include reliable, meaningful and specific test methods.

    2. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on May 14, 2026. It asked for a Form 483.

  • Inspection ending Mar 27, 2024

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on May 20, 2026. FDAgent holds no copy that FDA posted.

    1. May 14, 2026FDA-FOIA-2026-4962Form 483· 1 of 3 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.

Show all 9

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3011572099, one row per refused product line.

1 refusal on 2024-03-25 · charged NOT LISTED on 1, NO ENGLISH on 1 · no FDA sample analysis

FDA firm profile
  • 2024-03-25

    EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YAY99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    NO ENGLISH 502(c); 801(a)(3);Misbranding

    Division of Southeast Imports799-0230078-0/11/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2024-08-29

    FDA’s entry
    Outin Futures Corp · 154 Gieopdosi 1-Ro, Daesowon-Myeon, Chungju, Chungcheongbuk KOREA (THE REPUBLIC OF)
    FDA’s inspection record for FEI 3011572099
    Outin Futures Corp · 154 Gieopdosi 1-Ro, Daesowon-Myeon, Chungju, Korea (the Republic of)

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    15 products

    • 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
    • 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
    • 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
    Show 12 more products
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
OUTIN FUTURES CORP.D-U-N-S 689851514

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011572099 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011572099. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.