Hetero Labs Limited (Unit V)
Unit V, Sy. No.: 439,440,441&458, Tsiic Formulation Sez, Polepally Village, Mahabubnagar, India
FEI 3008307735DUNS 650452530
Company: Hetero Labs Limited · Linked by exact D-U-N-S match (917261950) in FDA registration data
FDA has 5 inspections on file for Hetero Labs Limited (Unit V) in Mahabubnagar, India (FEI 3008307735), from 2010 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection: 5 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 1 under 21 CFR Part 314, the rules for new drug applications. They are listed below. One of the two FOIA requests for this site asked FDA for the 483 from a later inspection, ending Aug 7, 2026, that FDA's Data Dashboard doesn't list yet.
The most recent OAI inspection ended on Dec 16, 2016. FDA issued a warning letter on (CDER). 4 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant, Hetero Labs Limited (D-U-N-S 917261950), has registered 6 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2010–2022
- 1 OAI · 2 VAI · 2 NAI
- Inspections with 483 observations shown
- 2 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest FY2023
- Warning letters
- · CDER ↗
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up.
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Show 1 more citation
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit document destruction
The responsibilities and procedures applicable to the quality control unit are not fully followed. (1) Specifically, your QA technicians and other individuals were recorded destroying and altering records pertaining to commercial batch manufacturing immediately prior to this regulatory inspection. The loss of data and documents are evidenced by the following: Through a review of your firm's Closed Circuit TV we identified the following: (a) A document shredder was introduced into your firm's "DOCUMENTS STORAGE AREA" on December 03, 2016 at 15:44, approximately 4 days prior to the current US FDA inspection. (b) After introduction of the document shredder we observed extensive shredding of what appears to be controlled documents and extensive signing of documents by QA. These documents were of a color consistent with batch packaging records and batch manufacturing records, among other documents. Your firm failed to maintain documentation of what had been shredded. (c) On December 06, 2016, at "" we observed that a contract employee with QA removed documents from the shredder and placed them in his pocket. (d) On December 07, 2016, at approximately 1:13 (in the middle of the night) individuals were shredding documents. Your firm stated this event represented cleaning staff shredding documents. (e) Other anomalous events were observed associated with this shredder. Your firm failed to clarify the correlation of introducing the shredder to the "DOCUMENTS STORAGE AREA" prior to the current U.S. FDA inspection. Your firm's Quality Manager stated that your firm has failed to maintain a log of what documents had been shredded and therefore fulfill their position. Under SOP QA001-11 titled "PREPARATION, REVIEW, APPROVAL, CONTROL AND REVISION OF STANDARD OPERATING PROCEDURE, FORMATS AND DOCUMENT CONTROL", Quality Assurance is responsible for "The storage arrangements must make reasonable provision to prevent loss of or damage to the documents." (2) On December 12, 2016, we observed the scrap area behind the production area of Buildings { and @ to contain controlled documents that had been discarded: (a) A balance printout with drug product "© * dated "14-Dec-2016". After discussing this finding with your firm, you failed to explain why the balance printout was post-dated by two days, and therefore indicating an alteration to dates on balances. Your firm's VP of Operations explained that not all balances are password protected. (b) A "GMP REPORT" indicating a test result of "PASS" with a start date "11/12/16". Your firm's Vice President of Corporate Quality Assurance initially purported that these test results represented a "credit card print from the market." (c) A printout indicating an "Abort" event of testing. (d) A plethora of documents with written numbers and signatures. (3) On December 07, 2016, we observed controlled documents in shred bins, shredders and trash bins as follows: (a) In the trash bin outside Building {} we observed the trash liner contained various controlled documents, including: original test results from November 26, 2016 at 12:52 and cleanroom certification reports from @ 2005. We observed the Hetero seal and official signatures as a part of this discarded record. (b) Inside a metal bin intended for shredding in the QA department Building {?} we observed discarded documents including: a signed and reviewed document dated December 07, 2016, in which it appears that the attachments to the document had been physically removed. (c) We observed a shredder in the QA portion of Building { inside a room termed "DOCUMENTS STORAGE AREA." We observed shreds of documents with the appearance of raw data (written numbers), cleaning logs, and other official documentation. Additionally many of the shreds of paper contained the Hetero seal; and what appeared to be original signatures from both QA and QC. (d) After observing the shredder in Building { as discussed in sub-point c, we proceeded to the QA "DOCUMENTATION CELL" in Bu
Shortened here; the PDF has the full text.
- Observation 2
Inconsistent PLC and batch records
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch Documentation pertaining to exhibit batches submitted to the Agency are incomplete and inaccurate. 1. Data derived from your firm's programmable logic controller (PLC) for compression machines is inconsistent with batch records and validation reports in support of applications to the Agency: (a) Batch record for © lot @@ states that compression machine PDE-2010 was run between 10:40 and ®" on 06/13/2015. However, the PLC shows ®® records for this same batch used to support a submission to the Agency termed "®® »@@". Per the PLC record, run "© " was initiated 15:01:03 on 06/12/2016, a full day prior to what is indicated on the BR. Your firm failed to provide documentation explaining the ®" separate runs under the same batch number. The process validation report PVR2008-01 is silent with regards to © runs under the same batch number. Furthermore, during the manufacture of this batch, a "Position failure" occurred that was not recorded or investigated. (b) Batch record for ®® @9 )lot™® states that compression machine PDE-2010 with Bra run between 9:40 and®® on 02/15/2016. However, the PLC shows ®® records for this same batch used to support a submission to the Agency termed "®@". The process validation report PVR2030-00 is silent with regards to ®® under the same batch number. The PLC record shows batch "®®" was initiated 09:18:54, a compression start time prior to what is indicated on the BR. Your firm failed to provide documentation explaining the separate runs under the same batch number. Furthermore, during compression, 6 alarms were encountered and not recorded or investigated, including: "Powder low level {} *", "Production out of range side 3)" and "Production out of range side {)". (c) Batch record for ©@@ ©" mg) lot ®® states that compression machine PDE-2010 with a®® run between ®® and ®® on 05/13/2016. However, the PLC shows ®" records for this same batch used to support a submission to the Agency termed "© "@@. The process validation report PVR2029-00 is silent with regards to © under the same batch number. Per the PLC record, run "©@" was initiated ©" a compression start time prior to what is indicated on the BR. Your firm failed to provide documentation explaining the ©" separate runs under the same batch number. Furthermore, during compression, an alarm was encountered and not recorded or investigated, including: "Production out of range side ;)". Note: The clock for PLC-2010 and clock in the room housing PLC-2010 were precise. For sub-points a—c, we were unable to reconcile the times listed in the BRs versus that indicated in the PLC, such that it is not apparent that BRs are completed contemporaneously. Of your firm's § pending ©" , 8 off fail to have reviewable alarm histories. Furthermore, {| of &) batches requiring compression for { pending" are conducted on equipment PDE-072, the sole compression machine that fails to retain electronic raw data. We reviewed logbook QAR0012/16 (PD) [January 1, 2016 through August 20, 2016] for unplanned deviations pertaining to production and noted that approximately 23% relate to deviations in compression, with the majority reflecting low compression yields and tablet defects. II. Alarms occurring during the manufacture of submission/validation batches are not documented, recorded or investigated. (a) During the manufacture of ®* @ mg Tablets batch "" , 13 alarms are indicated in the PLC. Some of these alarms pertain to "" compression out of range" and overallf;) startup events are required. However, the BR fails to capture any of these events and only notes a single start and end time for compression. The electronic records for the various PLCs note various alarms and human interventions across compression machines during the manufacture of various drug products. Your firm's management state
Shortened here; the PDF has the full text.
Show observations 3 to 6
- Observation 3
Incomplete complaint investigations
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up. (a) Your firm received a complaint (MCU16-010 product tablets {* mg lot ) for "One tablet in bottle was twice the thickness of all others and it has same markings and color as the other tablets." Your firm then conducted an investigation identifying "the possibility to generate the higher thickness and higher weight tablets is?" at the ® stage. The sample subject to the complaint was received from the consumer and you confirmed this weight disparity by measuring a weight of "mg versus a maximum specification of "mg (approximately 170% of specification). Various parameters had been altered between 2 ost batch subject to the complaint and the previous batch of the same product, such as was! from 0 among other adjustments. Your firm's investigation then concludes "If the patient consume the higher thickness/weight (double the thickness) by inadvertently no impact on the patient health and safety." As a part of preventative and corrective actions, your firm failed to remove the defective product from the market or otherwise ensure patients would not receive thick tablets. BE tablets’ mg lot®™" was provided to the US market. (b) Your firm received a complaint (MC016-002 product" 27 g lot™® and POE mg lot"?) for "dissolution testing at" results not meeting to specification limits." Your firm then conducted an investigation identifying all retain sample results were within specification. The sample subject to the complaint was received from the customer and your firm confirmed the dissolution disparity during testing of the complaint sample and a second retain sample. The investigation conclusion states "It is concluded that this batch is showing inconsistence results. This could be a batch specific issue." After confirmation of the OOS, your firm failed to remove the product from the market. For points a and b: Per your firm's "QUALITY SYSTEM MANUAL" document QM001-04, "Any batch found to be non-compliance to the specifications related to safety, identity, efficacy, purity and quality shall be recalled from the market. Moreover, according to SOP CQA012-01 titled "PRODUCT RECALL" indicates that a recall is to be initiated in the event of "Non-compliance with specifications (e.g. assay, stability, fill weight or dissolution)."
- Observation 4
Unrecorded consumer complaints
The written record or copy of the record of an investigation of a complaint conducted in relation to any unexplained discrepancy is not maintained at the establishment where the investigation occurred. Consumer complaints are not documented, recorded or investigated. (1) The following product quality complaints were not investigated, documented or otherwise handled: Product | Batch No. | Complaint Description TET | ide | 11-29-15 | Lack of drug effect El | unknown | Product did not work [os | unknown | Product shape issue EE | unknown | Lack of drug effect [103116] | unknown | Tablet in stool (Note: not an®®) Note: in some cases your firm indicated further follow-up was needed to ascertain the batch numbers of drug product subject to the complaint. Your firm has failed to define the required attempts to contact the patient in cases of product quality issues (SOP PV001-01 only speaks to adverse events). On 12/13/2016, your firm's Quality Manager and Assistant Manager of QA confirmed that your firm had not investigated and was not aware of the aforementioned complaints. The complaints were handled by Clinical Development and Medical Affairs (CDMA), a site not registered with the Agency, who neglected the associated product quality aspects of these complaints. Your firm failed to investigate additional complaints. (b) Complaints are received by © . 2 then provides the respective complaints to either/both the pharmacovigilance team (CDMA) and Hetero Unit-V. However, there was a discrepancy between the number of complaints (strictly product quality) received by Hetero Unit-V and CDMA. A discrepancy in complaint numbers presented throughout the inspection are indicated as follows: Source | Number of Complaints Indicated Hetero Unit-V | 34 CL | 17 Hetero CDMA | 26 Your firm could not reconcile the disparity of complaints received between your site, CDMA and ® (marketing for the US market).
- Observation 5
Poorly cleaned/maintained equipment
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. On December 9, 2016, all ®* recently cleaned (™") were in a condition unsuitable for the manufacture of drug products: All®® 5 referenced below are not dedicated to a specific drug product. (a) ®® PDE-369: This ®" equipment was in the "CLEANED" state. We observed white residue on the drug product contact surface of the lining. Furthermore, white residue was observed on the ®" surface above the ®®. Additionally, the interior of the transfer line used to move drug product from the "| to " was soiled with residue and a mold like appearance. The used for control of to the ®" displayed residue / accumulation (the side of the ®" facing the interior of the ). Moreover, the line between the ®® and ®" that provides an" displayed a reddish-brown discoloration consistent with rust. This equipment is used to manufacture the ® @ for ®@ capsules, the ®@ for ®® (©) (4) tablets, the @® for (©) (4) tablets, and the ®® for je tablets for the US market. (b) ®@" PDE-1231: This equipment was recently cleaned. We observed white residue on above the ®" to the ®® (the drug product contact surface). Additionally, the gasket above the ®" displayed an accumulation of a white substance facing the interior of the equipment. Finally, the surface directly above (and thus drug product) exhibited a residue. The ®® used for control of to the ®® displayed accumulations intercalated in the @® (the side of the ®® facing the interior of the ®" ). Moreover, the line between the ®® and ®@ that provides an" displayed a reddish-brown discoloration consistent with rust. The ®® to this ®® was deteriorated and discolored. This equipment is used to manufacture the ®" of 0 tablets for the US market. (c) ®" PDE-2095: This equipment was in the "CLEANED" state. We observed a white residue build-up with black specs around the torn gasket of the interior site ®® of the ®® . Your firm's Vice President CQA and Vice President of Operations stated the white residue was an accumulation from cleaning and the black specs were from welding. Furthermore, a residue was observed in the interior (product contact) of the outlet line to this ®®. This ®® is used to manufacture the ®" for ®® Tablets for the US market. The P® used for control of directly into the P® (© used) was 2 and in a®® like state. This®" is used to manufacture the ®® for ®® Tablets. (d) ®®" PDE-2005: This equipment was in the "CLEANED" state. © coloring and ®® coloring were both observed on the product contact surface of the ®" for the @ The operator did not know what caused the discolorations and your firm's Vice President of Operations stated it was due to a metal reaction. In addition, ®* particles were observed in the interior siding of the ®® . This ®* is used to manufacture the ®® for @@ and Jrabi tablets for the US market. (e) 2 (@® ) PDE-056: The surface of the equipment was heavily scratched. Document "BREAKDOWN WORK REQUEST NOTE" from February 2016 states "© touch on the®® base." Despite your firm's knowledge of the © contacting the base of this equipment, no assessment into potential metal shavings or associated product impact was conducted. This equipment is used to manufacture the ®® for © 2" Tablets for the US market.
- Observation 6
Undocumented hold time excursions
Deviations from production time limits are not documented. Excursions in hold time are not investigated, trended or otherwise evaluated for product impact. The following table contains examples of drug products and number of hold time excursions: (table omitted in OCR) Your firm's Annual Product Quality Review was silent in regards to manufacturing hold time excursions. Your firm's Quality Manager qualified this practice by referencing SOP QA058-07, which states "In case during commercial manufacturing if the product exceeds the established hold time period at any" (text truncated in OCR).
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Aug 7, 2026
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Oct 16, 2026. FDAgent holds no copy that FDA posted.
- Oct 6, 2026FDA-FOIA-2026-9695Form 483Records released
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-2543Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 5 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.198Complaint files1 of 1
- 21 CFR 314.81Other postmarketing reports1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3008307735, one row per refused product line.
4 refusals from 2018-12-07 to 2024-10-29 · charged UNAPPROVED on 3, NOT LISTED on 1 · no FDA sample analysis
FDA firm profile- 2024-10-29
LACOSAMIDE (ANTI-CONVULSANT)61MDY47
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-5798514-3/11/1
- 2023-10-06
LETROZOLE (ANTI-NEOPLASTIC)62IDA85
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-4013386-8/11/1
- 2019-03-22
VEHICLE, MOTORIZED 3-WHEELED89INI
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Southeast Imports147-0170496-8/11/1
- 2018-12-07
EFAVIRENZ (ANTI-VIRAL)62VDY24
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-8771027-1/11/2
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Hetero Labs LimitedD-U-N-S 917261950
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Hetero Labs Limited (D-U-N-S 917261950) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Hetero Labs LimitedMahaboob Nagar, India · FEI 30082943554 inspections4latestJun 26, 2026VAINone on file
- Hetero Labs LimitedHobli Vemagal, Kolar District, India · FEI 30228371181 inspection1latestJan 31, 2025NAINone on file
- Hetero Labs LimitedSangareddy, India · FEI 30043784466 inspections6latestSep 8, 2023VAINone on file
- Hetero Labs LimitedHyderabad, India · FEI 30054065268 inspections8latestJul 21, 2023VAINone on file
- Hetero Labs LimitedVisakhapatnam, India · FEI 30090937825 inspections5latestNov 8, 2022VAINone on file
- Hetero Labs LimitedAnakapalli, India · FEI 30110028331 inspection1latestAug 28, 2014VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3008307735 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3008307735. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.