Corixa Corporation
325 N Bridge St, Marietta, Pennsylvania, United States
FEI 3007726770DUNS 011553920
Company: GlaxoSmithKline Biologicals SA · Linked by exact D-U-N-S match (372748392) in FDA registration data
FDA has 5 inspections on file for Corixa Corporation in Marietta, Pennsylvania (FEI 3007726770), from 2015 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. Two of the four FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2027. Its registrant, GlaxoSmithKline Biologicals SA (D-U-N-S 372748392), has registered 8 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2015–2026
- 0 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 4 requests, latest Oct 16, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsPosted 483 · 1 citation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
input/output verification
Input to and output from the computer and records or data are not checked for accuracy.
Biological product deviation report
Failure to submit a biological product deviation report within 45 days from the date you acquired information suggesting that a reportable event occurred.
Identification of Equipment and Lines
The batch production and control records are deficient in that they do not include the identity of major equipment used.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Oct 16, 2026. Each one asked for a Form 483.
Inspection ending Mar 12, 2026VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Oct 16, 2026FDA-FOIA-2026-10080Form 483· 1 of 5 sitesRecords released
- May 5, 2026FDA-FOIA-2026-4472Form 483· 1 of 5 sitesClosed
Inspection ending Apr 15, 2019VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Nov 15, 2023FDA-FOIA-2023-10234Form 483No records found
- Oct 5, 2023FDA-FOIA-2023-8683Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services1 of 2
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, sterilization
- Registration runs through
- Dec 31, 2027
- Registrant
- GlaxoSmithKline Biologicals SAD-U-N-S 372748392
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names GlaxoSmithKline Biologicals SA (D-U-N-S 372748392) as the registrant for this site and the 8 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- ID Biomedical Corporation of QuebecQuebec, Canada · FEI 30048356478 inspections8latestMar 28, 2025NAI1 warning letter, Jun 12, 2014
- GSK Vaccines GmbHMarburg, Germany · FEI 30013147758 inspections8latestFeb 27, 2026VAINone on file
- SmithKline Beecham Pharma GmbH & Co. KG (dba GlaxoSmithKline Biologicals)Dresden, Germany · FEI 30048356187 inspections7latestMar 15, 2024VAINone on file
- GlaxoSmithKline BiologicalsSaint-Amand-Les-Eaux, France · FEI 30147526102 inspections2latestMar 12, 2024VAINone on file
- GlaxoSmithKline Vaccines SrlSovicille, Italy · FEI 30067385175 inspections5latestJan 26, 2024VAINone on file
- GlaxoSmithKline Biologicals SARixensart, Belgium · FEI 30028752265 inspections5latestJun 23, 2023NAINone on file
- GSK Vaccines S.r.l.Siena, Italy · FEI 30077805042 inspections2latestMay 29, 2017VAINone on file
- GlaxoSmithKline Biologicals SAWavre, Belgium · FEI 3003973577Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3007726770 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3007726770. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.