BioCentric Labs Inc
854 Baseline Pl, Brighton, Colorado, United States
FEI 3007670366
FDA has one inspection on file for BioCentric Labs Inc in Brighton, Colorado (FEI 3007670366). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 18 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2009
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance18 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
Identification of containers, lines, equipment
All compounding and storage containers used during the production of a batch of drug product is not properly identified at all times to indicate contents.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Written sanitation procedures lacking
There is a lack of written procedures assigning responsibility, providing cleaning schedules, and describing in sufficient detail the methods, equipment and materials to be used for sanitation.
Review of problem drugs
The procedures for the annual quality standards record evaluation are deficient in that they do not address a review of complaint, recall, returned drug product, and investigation records for each drug product.
Show 13 more citations
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Lack of quality control unit
There is no quality control unit.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, and packing of a drug product lack the education, training, and experience required to perform their assigned functions.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning, sanitizing, and inspection of equipment.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.56Sanitation1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.105Equipment identification1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
Show all 17
- 21 CFR 211.130Packaging and labeling operations1 of 1
- 21 CFR 211.142Warehousing procedures1 of 1
- 21 CFR 211.150Distribution procedures1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.198Complaint files1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007670366 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007670366. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.