Skip to content

Chiesi USA, Inc.

175 Regency Woods Pl Ste 600, Cary, North Carolina, United States

FEI 3006389494

FDA has 9 inspections on file for Chiesi USA, Inc. in Cary, North Carolina (FEI 3006389494), from 2009 to 2026. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Mar 24, 2010. FDA has issued 3 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 211.110(a).

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
9, 2009–2026
1 OAI · 1 VAI · 7 NAI
Inspections with 483 observations shown
2 of 9
Form 483s posted by FDA
None held for this FEI
Warning letters
· CDER ↗
3 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  2. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  3. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  4. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  7. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not justified.

    2. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    3. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    4. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

    5. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    3. Contamination, chemical or physical change, deterioration

      An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.

Regulations FDA cited here

The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 9 inspections, with how many of them cited each.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006389494 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006389494. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.