Coastal Meds, LLC
1759 Medical Park Dr Ste C, Biloxi, Mississippi, United States
FEI 3005180755
FDA has 3 inspections on file for Coastal Meds, LLC in Biloxi, Mississippi (FEI 3005180755), from 2014 to 2018. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Oct 24, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Sep 23, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2014–2018
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 3 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate environmental monitoring
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, environmental monitoring (EM) samples are not taken in high-risk areas or so that they represent the conditions of the areas being monitored. For example: a. The material pass-through box, which is used to transfer materials between the uncontrolled dispensing room and the ISO7 clean room, is not monitored on any frequency. [illegible] b. Fingertip samples are taken [illegible] The sample is also limited to (b)(4) [illegible] c. The surface sample taken from the (b)(4) treated in the ISO7 cleanroom, is performed after the (b)(4) has been sanitized with sterile (b)(4) d. On 3/13/2018, I noted the surface sample taken from surface of the (b)(4) [(o)-(4)] was done in an area still wet with sterile (b)(4) e. Pressure differential data is not reviewed. It is recorded on a (b)(4) and when anomalies occur. Data is uploaded (b)(4) and printed. The electronic files are not saved and there is no review of the data. As a result, there have been no explanations for or investigations into pressure loss. For example, the following pressure differential excursions were recorded on 12/5/2017: ISO7 AnteRoom .to General Area ISO 7 Cleanroom to ISO7 AnteRoom Specification: (b)(4) (b)(4) 0.062 0.026 0.004 0.002 0.008 0.002 0.010 0.011 0.026 0.02 0.064 0.014 0.008 0.025 0.036 0.005 0.028 0.065 METHYLCOBALAMIN, Lot MC/120517, was produced the same day and later distributed. There is no explanation for or investigation into this series of events.
- Observation 2
Inadequate protective eyewear
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, on 3/13/2018, I observed the aseptic attire worn in the cleanroom does not include goggles, which leaves the skin of personnel exposed around their eyes and forehead. * * *THIS IS A REPEATED OBSERVATION*
Show observations 3 to 11
- Observation 3
Uncalibrated pressure gauges
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, the pressure gauges used to monitor the differentials between the cleanroom, ante room, and uncontrolled areas, are not calibrated.
- Observation 4
Inadequate laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, a. Visual examination of finished products is not performed under appropriate conditions to identify potential quality issues with injectable drug products. Per SOP 0-16, Rev. 0, Testing and Release Criteria, effective 12/30/2016, visual inspectors should look for fill volume, particulate matter (PM), container seal/closure, or any other defect. It states PM should be identified using a contrasting background illuminated with (b)(4) lights or brighter. Visual inspectors are not provided with a contrasting background and sufficient light for inspection. All products are packaged in amber vials and numerous products are light to dark red in color. On 3/13/2018, inspectors were not observed holding vials up to the ceiling lights, the only light source available, during their visual inspection. There is no assurance quality defects are identified during visual inspection of injectable drug products. b. Finished product release testing does not include (b)(4) content, the preservative used in all injectable drug products.
- Observation 5
Insufficient sterilization validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, a. Pharmaceutical grade, sterilizing [illegible] are (b)(4) after use via a (b)(4) that is not in compliance with the manufacturer's test method and has not been independently validated. Per SOP 0-14, Rev. 0, Validation of Sterilization Methods, effective 12/30/2016, the used (b)(4) [illegible] (b)(4) to (b)(4) of (b)(4). The (b)(4) is reached when (b)(4). Per the manufacturer the used (b)(4) is used prior to obtaining the (b)(4). There is no assurance the sterilizing (b)(4) results are passing. b. Media fill records lack significant information. There is no record of media preparation, the materials used (including the vials, tubing, and sterilizing (b)(4)), the filling process followed, or the number of vials placed in the incubators. In the most recent revision of the media fill record, there is no record of the number of vials which were filled.
- Observation 6
Unsuitable cleanroom materials (rust)
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning. Specifically, the materials used for equipment within the ISO7 cleanroom are not appropriate for the cleaning solutions being used. On 3/13/2018, I observed rust on several HEPA return grates, the ante room door handle, and doorframe.
- Observation 7
Inadequate batch failure investigations
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has already been distributed. Specifically, since 9/24/2015, there have been at least 23 batches found to have potency failures and 13 found to have sterility failures. Each batch was rejected, but investigations lack significant information and do not extend to other similar batches. The QRE (quality related event) investigation forms were initiated beginning in 2017 and each event was classified as "Minor". For potency failures, thirteen (13) out of the 23 were presumed to be due to weighing errors. The others had potential root causes of incomplete dissolution, light exposure, or none listed. No evidence was provided in any case to support the conclusions. METHYL-PLEX was discontinued due to potency failures for three (3) consecutive batches in 2018. No other product formulation incompatibilities were considered during the investigations. For sterility failures, each investigation concludes aseptic technique should be followed and hand hygiene sampling was performed. Organisms were identified in seven (7) out of the 13 events and Bacillus circulans was identified as the organism in four (4) out of the seven (7) events. Documentation was not reviewed, environmental conditions were not reviewed, EM sampling results were not reviewed, the identified organisms were not evaluated, and these events did not trigger cleaning. In all investigations, there is a lack of historical review, trend analysis, extension to other batches, a statement regarding product disposition, and overall quality impact assessment. ***THIS IS A REPEATED OBSERVATION***
- Observation 8
Containers/closures not QC-released
Each lot of drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit. Specifically, sterile, depyrogenated drug product containers and closures are accepted after confirming they match the purchase order, without requiring sampling, testing, examination, or release. There is no specification for the containers and closures; there is no requirement to obtain and review the manufacturer certificate of analysis (COA) for each batch received.
- Observation 9
No stability studies for products
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, stability studies have not been initiated for all injectable drug products to support their 6-month (180-day) expiration date. Since 9/24/2015, the following products have been made and distributed without stability studies being initiated/performed: • ADENO-PLEX • HYDROXOCOBALAMIN • L-CARNITINE • LIPO-DEN EXTREME • LIPO-DEN MAX • LIPO-DEN PLUS • LIPO-PLEX • UPO-X • METHYLCOBALAMIN • METHYL-PLEX • PYRIDOXINE • RODEX * * THIS IS A REPEATED OBSERVATION ***
- Observation 11
Drug labels missing required information
The labels of your outsourcing facility's drug products are deficient. The labels of some of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) and (B). Specifically, the following information is not found on some of your drug product labels, as required by section 503B(a)(10)(A): The dosage strength; The statement, "Not for resale" In addition, the following information is not found on your drug product container labels, as described in section 503B(a)(10)(B): • Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088 Examples of drug product labels that do not contain this information: o Adeno-Plex Injectable 30 ml o Cyanocobalamin injectable 30 ml o Hydroxocobalamin injectable 30 ml MDV o Lipo-B injectable 30 ml o Lipo-Den injectable 30 ml MDV o Lipo-Den Extreme injectable 30 ml MDV o Lipo-Den Plus injectable 30 ml MDV o Lipo-Plex injectable 30 ml MDV o Methylcobalamin injectable 30 ml MDV o Pyridoxine injectable 30 ml MDV
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing, processing, and packing of drug products is not appropriate for the duties they perform.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Show 3 more citations
Adverse Drug Experience
Complaint procedures are deficient in that they do not include provisions that allow for the review to determine if the complaints represent serious and unexpected adverse drug experiences which are required to be reported to FDA.
Written procedures describing in detail
There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, and examination of labeling and packaging materials.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Show 4 more citations
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Pkg / Labeling Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the packaging and labeling operations.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.137Expiration dating2 of 2
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.111Time limitations on production1 of 2
- 21 CFR 211.122Materials examination and usage criteria1 of 2
- 21 CFR 211.166Stability testing1 of 2
Show all 10
- 21 CFR 211.167Special testing requirements1 of 2
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005180755 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005180755. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.