FDA has 2 inspections on file for Pharmedium Services, LLC in Lake Forest, Illinois (FEI 3005051736), from 2016 to 2018. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated May 9, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
FDA issued a warning letter on (CDER). FDA's compliance record also lists one other action under this FEI: Injunction, . No import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.192.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2016–2018
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Responsible firm officials notified in writing
Procedures are not established which are designed to assure that the responsible officials of the firm, if they are not personally involved in or immediately aware of such actions, are notified in writing of investigations conducted.
Investigations made into any unexplained discrepancy
Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Reader/Photocopy equipment not made available
Suitable reader or photocopying equipment was not made readily available for drug product records maintained using reduction techniques. Electronic records are used, but they do not meet systems validation requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
Show 1 more citation
Supervisor Training/Education/Experience
Individuals responsible for supervising the manufacture and processing of a drug product lack the training to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components and drug product containers and closures and drug products conform to appropriate standards of identity, strength, quality and purity.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates .
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy .
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Reactive/Additive/Absorptive Containers/Closures
Drug product containers or closures are reactive so as to alter the safety, identity, strength, quality, and purity of the drug beyond the official or established requirements.
Show 1 more citation
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.94Drug product containers and closures1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.167Special testing requirements1 of 2
Show all 10
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- InjunctionCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005051736 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005051736. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.